DSC SG-SYSTEM 5 - Installation Guide - ENG - V1 1
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-sg-system-5-installation-guide-eng-v1-1-1287645039.pdf |
---|---|
Type | |
Size | 3.08 MB |
Downloads |
Text Preview
SG System 5 Guide the full Installation Manual visit www dsc com This manual contains information regarding product use and function in addition to manufacturer liability and pertaining to it The entire manual should be read carefully 5 Overview 5 Overview SG System 5 is a multi platform receiver intended for remote monitoring of commercial fire and burglary systems The SG System 5 can monitor to 24 communication line cards SG DRL5 IP or SG DRL5 DRL5E DRL5 2L to receive and process alarm data in up to 64 pre programmed pro per line card The SG System 5 s real time clock date stamps all received alarm signals which are then transmitted to a central station computer via or RS 232 port transmitted directly to a printer using the serial printer port and or TCP IP and viewed on the LCD of the front panel while the is in the manual state Options can be programmed using a PC with SG System 5 Console or locally using the touchscreen LCD this guide in conjunction with the SG System 5 v1.1 Operating Manual which you can access from the dsc com web site redundancy SG System 5 can be used in a redundant configuration using two SG CPM5s where the primary SG CPM5 backs up to the secondary SG CPM5 vice versa Under normal conditions the primary SG CPM5 is active and outputs all signals to the printer and automation while the secondary SG is in standby If the primary fails the secondary SG CPM5 automatically switches to active within 30 seconds and starts outputting signals to printer and automation During the switchover from standby to active signal reception is not affected since the line cards are still able to receive sig The output to printer and automation is delayed by the length of time required to switch from standby to active 1 1 SG System 5 front with door closed Thumb screws to hold faceplate closed Line card status indicators top LED is watchdog middle LED is status and LED is network SG CPM5 Status LEDs from left to right Console Trouble Network Automation Quick HOME button 7 inch resistive touch LCD screen 1 2 SG System 5 front with door open 1 3 SG System 5 back Use only 26 AWG wires for the Telco connections 2 3 4 5 1 2firealarmresources com basic configuration consists of one 19 inch rack mounted chassis comprising the following SG MLRF5 Metal rack of the SG System 5 with SG MP5 SG PSU5 600 600W power supply unit provides power to all system modules SG PSU5 250 250W power supply unit provides power to all system modules SG CPM5 Central processing module controls all communication to and from receiver modules and printers SG UIB5 Touch screen user interface SG DRL5 IP Internet protocol line card SG DRL5 IP PAD Paddle card for SG DRL5 IP provides network connection SG MLRF5 RM Rack mount rails SG S5LFANTR Line card fan tray SG S5CFANTR SG CPM5 fan tray SG S5SERCAB Y cable for serial connection to the SG CPM5 for automation printer SG SYS5MEM4 Removable EMMC memory SG SYS5DDR31 DDR3 RAM 1GB SG CPM5BATT SG CPM5 real time clock battery SG DRL5 Single line PSTN card SG DRL5E Single line PSTN card with backup channel and 2 way audio bridge SG DRL5 2L Dual line PSTN card SG DRL5PAD Paddle card for SG DRL5 DRL5E DRL5 2L PSTN cards SG ADPT5 Adapter card for SG DRL5 DRL5E DRL5 2L PSTN cards cm cm cm VAC 50 60Hz max RMS 100VAC max RMS 100VAC UPS not supplied in in in rack space 5 UL Electrical voltage current 600W current 250W power supply a two SG CPM5 configuration a redundant SG PSU5 can be inserted in the second slot In the event of a SG PSU5 failure the redundant SG automatically assumes operation These modules are hot swappable can be removed and replaced while the system is in operation if a working SG PSU5 is installed Both PSU units used in the system must have the same power rating Line Security Levels UL ULC Listed Installations Compatible communication formats ULC Passive channels active channels or P1 P3 passive channels 32 120 RH non condensing DPU 414 CID 128 bit approvals UL 1610 Central Station Burglar Alarm Units UL 864 10th Edition Standard for Control Units and Accessories for Fire Alarm Systems CAN ULC S304 2016 REV1 Control Units Accessories and Receiving Equipment for Intrusion Alarm Systems CAN ULC S559 13 Equipment for Fire Signal Receiving Centres and Systems EN60950 1 2006 Standard for Information Technology Equipment AS NZS 60950.1 2003 Information Technology Equipment Safety CISPR22 Class B Information Technology Equipment Radio Disturbance Characteristics Limits and Methods of Measurements EN50130 4 Immunity requirements for components of fire intruder and social alarm systems NIST validation certificate number 2913 for AES 128 bit encryption 3 UL listed installations the equipment must be installed in accordance with the requirements of NFPA72 NFPA70 UL827 and the authority having 5 with SG DRL5 IP Line Card is ULC listed for active communication channel security level A1 A4 when used in conjunction with T TL250 and TL260 R TL280LE R LE2080 R TL280 R E TL880LT TL880LE LE9080 3G9080 HS3128 032 248 LE4020 CF and 3G4010 CF Internet Intranet and or GSM GPRS alarm communicators For this type of application the supervision encryption features have to be enabled The receiver can be used also in conjunction with ULC listed passive communication systems based on the of the systems at the protected premises ULC Installations the equipment must be installed in accordance with the requirements of ULC S561 and ULC S301 Standards and the authority jurisdiction SG System 5 with SG DRL5 DRL5E DRL5 2L PSTN line cards is ULC listed for passive communication channel security levels when used in conjunction with compatible alarm systems using Industry Open SIA standard communication formats Contact ID or SIA product has been approved by the California State Fire Marshal CSFM pursuant to section 13144.1 of the California Health and Safety Code CSFM Listing No 7300 1273 0157 for allowable values and or conditions for use concerning material presented in this document The approval is to reexamination revision and possible cancellation ULC S304 applications the heartbeat timer option 411 shall be set to 30 seconds UL864 Commercial Fire applications the following compatible communicators can be used with receiver model SG System 5 SW Ver 1.1x SW Ver 5 x SW 4 x SW 4 x 1.5 transmitter supervision option 221 in SG DLR5 IP line card shall be set to 60 min for single path and to 6 h for multiple path performance technologies programming requirements Users Installers Authorities having Jurisdiction and other involved parties this product incorporates field programmable soft In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarms UL 864 certain programming features or options must be limited to specific values or not used at all as indicated below UL864 programming requirements option in UL864 Y N Possible settings Settings permitted UL 864 Timer 1 Fan Trouble 2 Fan Trouble 1 Trouble 2 Trouble AC 1 Trouble AC 2 Trouble Battery 1 Trouble Battery 2 Trouble Automation Sec 1 Trouble CPM 1 Printer 1 Trouble CPM 2 Printer 1 Trouble CPM 1 Printer 2 Trouble CPM 2 Printer 2 Trouble Automation Pri Trouble Automation Sec 1 Trouble Printer Pri 1 Trouble Printer Sec 1 Trouble option Supervised Accounts Exceeded Trouble Absent Debounce Time Restoral Debounce Time Unencrypted Trouble Account Trouble Allowed 00 permitted UL 864 sec 1 h 21600 sec 6 h in UL 864 Y N 4