DSC SG-SYSTEM II Quick Install Guide (English)

File Preview
File Preview
Click below to download for free

File Data

Name dsc-sg-system-ii-quick-install-guide-english-5194237086.pdf
Type PDF
Size 853.58 KB
Downloads

Text Preview

Sur Gard System II Line Network Receiver Install Guide SG System II is a single line network receiver intended for remote monitoring of fire and burglary systems The system can be configured for desktop operation vertical stacking of up to 4 systems or rack mounting The SG II is capable of communicating with up to 1536 transmitters including 512 that be supervised on two separate account tables System must be rack mounted for UL ULC listed installations SG System II real time clock and calendar stamps receive alarm data which is to a central station computer via a TCP IP serial port or a USB port The is then transmitted directly to a printer using the parallel or serial printer port it is viewed on the LCD of the front panel System configuration can be pro using a PC with SG Systems Console Software or locally using the scroll and LCD SG System II receives alarm information from panels over a LAN WAN or the of The Box that you have received the following II SG System II Receiver Qty 1 SG System II Console Software CD includes operating manual Qty 1 SG System II Quick Install Guide Qty 1 Rubber feet Qty 4 II Rack Mount Kit UL Installation Opt ULC Installation Req Brackets Qty 2 Rails mounting Qty 4 Screws Qty 8 Quick Install Sheet Qty 1 Equipment Required Not Supplied IEC power line cord Qty 1 CAT 5 ethernet cable for WAN interface support Qty 1 CAT 5 ethernet cable for LAN interface port or cable for console communication Qty 1 DB9 terminated RS232 serial cable Qty 1 DB25 terminated parallel printer cable Qty 1 Voltage 100 240VAC 50 60Hz Current 0.7A Max Power Supply External UPS not supplied 32 122 0 50 93 RH Non Condensing 305mm 12.25in 311mm 1.75in 45mm 7.92lbs 3.58 Kg of Accounts 1024 MAX of Supervised Accounts 512 MAX UL ULC Listed Installations DMP SCS PTR Seiko DPU 414 Seiko DPU 414 Do NOT use printer cables that have only 1 common ground wire Approvals SG System II meets the requirements of the following standards UL 1610 Central Station Burglar Alarm Units UL 864 Standard for Control Units and Accessories for Fire Alarm Systems CAN ULC S304 06 Signal Receiving Centre and Premises Burglar Alarm Con Units CAN ULC S559 04 Equipment for Fire Signal Receiving Centres and Systems EN60950 1 2001 Standard for Information Technology Equipment AS NZS 60950 2000 Information Technology Equipment Safety CISPR22 Information Technology Equipment Radio Disturbance Characteris Limits and Methods of Measurements EN50130 4 Immunity requirements for components of fire intruder and social systems equipment shall be installed in accordance with the requirements of NFPA72 and the authority having jurisdiction For ULC installations the equipment be installed in accordance with the requirements of ULC S561 and ULC S301 and the authority having jurisdiction Programming Requirements Users Installers Authorities having jurisdiction and other involved parties product incorporates field programmable software In order for the product to with the requirements in the Standard for Control Units and Accessories Fire Alarms Systems UL 864 the programming features or options must be as indicated below All of the following program options are permitted in as indicated Program Option 864 Frequencies DEFAULT OFF OFF OFF OFF OFF 01 04 05 00 30 255 Sec 05AH 90 Secs OFF OFF OFF OFF OFF Mute Buzzer Mask UPS AC Mask UPS BAT Mask Parallel Printer Mask Serial Printer Mask USB Printer Busy Out TX Failure Debounce Time Mask TX Restoral Mask TX Failure Mask TX Swap Mask TX Unencrypted Mask Invalid Report Compatibility following is a list of compatible Automation Software manufacturers MAS S I S Automation connections are considered supplementary per UL864 listing with the automation software in a system used at a central station is to be handled under a separate UL1981 software and or site certification SIMS II MicroKey DICE IBS Bold UL ULC Installations Supply 120VAC 60Hz Output Rating 120VAC 60Hz 2.5A Use UL ULC CSA listed UPS power supply for protective signalling systems and listed burglar power supply as applicable When a Hub or Router Gateway is used with the SG System II 24 hr Power is required for these devices i e UL listed UPS battery backup or driven generator 9 0 0 7 3 6 4 R0 0 3 Digital Security Controls Canada www dsc com 1 888 888 7838 Support Canada USA 1 800 503 5869 in Canada reduce the risk of electrical shock the SG System II is equipped with a ground type power supply IEC receptacle Connect SG System II using an appropriate IEC cable to a grounded receptacle Connect SG System II to UPS dry contact connections only Do NOT connect to a receptacle controlled by a switch CE Installations Supply 240VAC 50Hz Output Rating non UL 240VAC 50Hz 2 3 4 Open Collector 20 mA Max 18 22 AWG 0.5 1.0mm wiring II SG System II I O SG System II grounded receptacle 1 2 3 Low Bat normally closed AC Trouble normally closed Out In AC Mains to the Sur Gard System II Operating Manual PN for Installation and Programming details external devices connected to item 10 17 in the same as the SG System II 1 4 6.5mm separation between power limited and limited circuits All circuits are supervised and power Cable length is 1.8m 6ft Longer cables may impair Use at own risk messages are indicated on the Trouble LEDs and on the LCD If a trouble condition is displayed on the LCD is NOT indicated on the Trouble LEDs ensure that the unit is an

Related Files