DSC TL-250 with 5020 Quick Install Guide WEB

File Preview
File Preview
Click below to download for free

File Data

Name dsc-tl-250-with-5020-quick-install-guide-web-9418032756.pdf
Type PDF
Size 607.58 KB
Downloads

Text Preview

Install Guide February 2 2006 with 5020 Quick Install Guide Receivers III with a DRL3 IP line card Panels version 3.2 or greater Rev03 hardware required Overview T LINK TL250 is a network communicator that sends alarm system information to the central and allows you to also perform uploads and downloads of the panel through the DLS you Begin programming the T Link TL250 module obtain the following information from the Network The static IP address for the T Link TL250 module only if static IP address is going to be The subnet mask for the T Link TL250 module only if static IP address is going to be The receivers IP address The gateway IP address 1 Resetting to Factory Defaults Defaults Remove power from the T Link TL250 disconnect battery and the control panel if Connect a jumper wire between the PGM1 and IN1 terminals Apply power to the system Wait approximately 20 seconds then remove the jumper between PGM1 and IN1 Install Guide 2 Connect the TL 250 to the Alarm Control Panel Secure the T Link module to the side of the cabinet using the supplied standoffs With both AC and battery disconnected from the DSC control panel wire the T Link TL to the panel using the supplied cable Wire the panel s AUX and to 12V and GND terminals of T Link TL 250 Apply AC and DC to the main control panel Both the T Link TL 250 and the panel should Perform necessary programming that is required up 3 Programming Program the hex digits DCAA in the telephone number that will be used for T Link communications Section 301 to 303 Program the communication format to SIA FSK Section 350 Auto SIA option 3 in 381 has to be OFF Program the call direction options Section 351 to 376 Program the Active option to ON to enable communication through the T Link Section 382 Option 5 T Link TL250 module programming options Section 851 Program the static IP address for the T Link TL250 module Section 001 Program for DHCP Program the subnet mask for the T Link TL250 module Section 002 this option will ignored if the unit is set for DHCP Program the static IP address of the receiver Section 007 Program the T Link account number Section 003 the receiver is on a different network segment than the T Link TL250 module the address associated with the T Link TL250 module must be programmed 008 After all T Link TL250 module programming is complete you must restart the module so programming changes will take effect To restart the T Link module enter the digits in T Link TL 250 programming section 999 and wait 15 seconds for the module to Once complete press the key to exit T Link TL250 programming Install Guide 4 Testing Verify that the STAT LED is flashing once every 5 seconds if not please procedure to the Trouble Shooting section Call the Central Station and put your account on test Trip a zone on the DSC control panel Call the Central Station and verify that the correct signal was received Shooting LED Diagnostics LED will turn on when the network is present and will blink when there is network activity LED will remain off for 10BaseT network connection and will be on to indicate 100BaseT connection will blink to show network activity Status The STAT Status LED will normally blink once every 5 seconds Should a be present the LED will blink a number of times as per table with a one second pause restarting the sequence Should there be more then one trouble present the LED will blink a rate that is equal to the highest priority The transmitter has a number of individually trouble conditions that report various troubles present on the transmitter Blinks Absent Account 1 Absent Ethernet link between the transmitter and local hub or router is absent is equivalent to the link LED on the Ethernet chip being off transmitter account code is still set to the default value of FFFFFF transmitter is not receiving Receiver Heartbeat commands from the the case of a DSC 4020 or 5020 panel the transmitter is not receiving from the panel through the PC Link interface In the case of a generic the panel is not supervised by the transmitter are Inputs on the T Link which are in the alarm condition failed to communicate with receiver 1 PC5108 Module is not responding to the transmitter PC5108 Module Tamper has been activated failed to communicate with receiver 2 system was armed by the key switch zone is being programmed remotely Alarms 1 Absent Tamper 2 switch Arm Remote Local at any point you experience any problems of have additional questions in reference to operation of the T Link TL 250 please call the DSC Technical Support department at Monday to Friday 8am 8pm EST transmitter is not able to connect to receiver 2 on power up is being programmed locally

Related Files