DSC VPM5580 v1 0 - Installation Manual - v1 0 - PowerSeries Communique Security Interface Module

File Preview
File Preview
Click below to download for free

Text Preview

System Introduction Security Interface Card 5580 Module Current Draw 150 mA Prompting All prompts are in complete sentences using a pleasant easy to understand female voice All keypad commands are available Panel status is constantly announced when applicable including bypass trouble alarm and zone status 250 system words 240 words for programming labels Powerful number command can announce any number from 0 through 999 in three ways Labels System Zone Labels Automation Item Labels Automation Mode Labels Miscellaneous System Labels System Partition Labels item Control Requires the connection of the PL 513 or PSC04 Controller Module Control up to 32 Line Carrier Automation Items 16 Schedules with On Time Off Time and Day of Week Mask 8 User Controlled Automation Modes A full range of dimming levels for Lighting Control Event Activated Control for any PGM Output Option Supported by the main Control Panel Global On Off Command All Communiqu Security Interface Card 5580 Programming can be done via the DLS Started following steps are provided to assist with the installation of the Communiqu Security Interface 5580 module If you are unfamiliar with the Communiqu Security Interface Card 5580 module it suggested you follow these steps in order to help prevent problems and reduce the overall time 1 Steps the Security Interface Card connect the Security Interface Card to the main CPU board perform the following steps Fasten the two standoffs provided with the interface card to the threaded studs at the corners of the Security Interface Card section of the control unit Line up the female connector on the interface card with the male connector labelled VPM the control unit and firmly press them into place Fasten the two screws provided with the interface card to the standoffs to secure the in place The Keybus should remain disconnected until the Communiqu is powered up all stations have been initialized Permanent damage could result to the Security Interface Card or the control if the connections are offset You must ensure that proper connections are made applying power to the control unit 2 the KEYBUS Section 2.2 the 4 wire KEYBUS in accordance to the diagram in Section 2.2 Wiring 3 4 5 6 the Communiqu Security Interface Card 5580 Module Section 2.3 the Communiqu Security Interface Card 5580 Module in accordance to the guideline in Section 2.3 the Communiqu Security Interface Card 5580 Module the PL 513 or PSC04 Controller Section 2.4 the installation also includes automation items connect the PL 513 or PSC04 Controller in to the diagram provided in Section 2.4 the PL 513 or PSC04 the Communiqu Security Interface Card 5580 parameters of the Communiqu Security Interface Card 5580 can be programmed via local touch tone telephone Follow the guideline provided in Section 4 to the System the Communiqu Security Interface Card 5580 using both local and remote telephones ensure both operate properly Check all programmed labels and the operation of all including automation items if connected Wiring Communiqu Security Interface Card 5580 module has 4 terminals marked KEYBUS black yellow and green Connect these four terminals to the 4 terminals on the main panel marked KEYBUS red black yellow and green Connection the KEYBUS is not wired the Communiqu Interface Card 5580 not operate properly the Communiqu Security Interface Card 5580 Module Communiqu Security Interface Card 5580 will function properly as soon as all wiring is and power is applied However to fully supervise the Communiqu Security Card 5580 from the main control panel you will need to follow these steps on the PC5010 1 Wire the Communiqu Security Interface Card 5580 module to the keybus 2 At a keypad enter Q 8 Installer Code to enter Installer Programming 3 Enter section 902 followed by the key to exit Installer Programming The panel automatically search for all modules on the system The search takes 1 minute From this point on if any modules are removed from the a Supervisory Trouble will be generated 4 To confirm supervision re enter Installer Programming and then enter section 903 LED keypads light 24 ON represents successful Communiqu Security Card 5580 supervision On LCD keypads the description Communiqu Interface Card 5580 will be displayed if successful 5 If this is not successful check all wiring to the Communiqu Security Interface Card on the PC1575 are supervised on installation see section 2.6 of 1575 Installation Manual 1 Wire the Communiqu Security Interface Card 5580 module to the keybus 2 At a keypad enter Q 8 Installer Code to enter Installer Programming 3 Enter section 92 Installer Code 92 followed by the key to exit Installer The panel will take approximately 1 minute From this point on if any are removed from the system a Supervisory Trouble will be generated 4 If this is not successful check all wiring to the Communiqu Security Interface Card the PL 513 or PSC04 Controller an RJ11X connector and cable not supplied to connect the Communiqu Security Card 4580 to an X 10 PL 513 or X 10 Pro PSC04 module Refer to and follow the instructions for installing the PL 513 or PSC04 module following diagram show the cable that we currently require for connecting the Security Interface Card 5580 to the PSC04 PL513 With the jacks side by side facing up the colours of the wire in each jack will appear in the same order from left right This cable is called a Through Cable as per telephone industry standards do not use a or cable as it will not work with the Security Interface Card 5580 more information on and through cables please see Getting Started in the Communiqu manual the Security Interface Card Software replace the Security Interface Card software the Communiqu must first be completely down battery and AC Next unplug the keybus and X 10 cable from the Remove the old software and replace it with the new software Restore power to Communiqu and wait until all stations have been initialized The Keybus and X 10 may now be plugged back into the TSVPMBRD All programming related to the Security Interface Card will be lost and will have to be the Communiqu Security Interface Card 5580 Locally access your security system from a Communiqu telephone set press the SECURITY If you are using a Communiqu DAI station press S F Security Functions The If the User Code Required for Local Access option is enabled will announce TSVPMCRD will announce Your Access Code Your Access Code Access to the security system will Your Access Code Your Access Code Your Access Code be granted until a valid access code has been entered Invalid access codes do count Main Panel Keypad Lockout see the Lockout section of your system Manual section 5.22 of the PC5010 Manual or section 5.19 of the PC1575 the Communiqu Security Interface Card 5580 the Remote Access option is enabled the security system can also be accessed remotely any touch tone phone in the world The following are the steps required to access your system remotely 1 Call your telephone number and wait for the automated greeting 2 During the greeting press the Q key along with a remote access code if and the system will announce a F a F a F Option Option

Related Files