DSC Wireless PowerG Digital Pet-Immune PIR Motion Detector PGx914 - Installation Manual

File Preview
File Preview
Click below to download for free

Text Preview

PG4914 PG8914 PG9914 Wireless PIR Pet Immune Motion Detector Installation PGx914 pet immune is a microprocessor controlled wireless digital PIR supported by DSC alarm systems using PowerG two way protocol detector features are as follows and cylindrical lenses with uniform detection sensitivity its operating range up to 12 meters 39 ft Specific Imaging TSI technology is used for distinction humans and pets weighing up to 38 kg 85lb advanced True Motion Recognition algorithm patented between the true motion of an intruder and any other which may cause false alarms No vertical adjustment is needed Motion event counter determines whether 1 or 2 consecutive events trigger an alarm low current consumption Microprocessor controlled temperature compensation Sealed black provides white light protection and back tamper protection device supports temperature and light level reports to alarm systems that support temperature and light UL installations The detector is for use with UL listed control units Pet immunity has not been evaluated by UL Enroll button Light sensor LEDs Tamper switch PIR sensor View INSTALLATION Guidance Keep away from heat Do not expose to air Do not install outdoors Avoid direct sunshine Do not install near high electrical lines Do not install behind Mount on a solid stable Do not partially or obscure the field of view Procedure Surface mount Corner mount B1 or B2 Back tamper PGx914 Installation Instructions Cover Base Press in point The detector transmits a low battery signal upon detection of low It is recommended to wait about 1 minute after battery removal inserting the new battery shall be installed in accordance with the Standard for Installation and of Burglar and Holdup Alarm Systems UL 681 Risk of explosion if battery is replaced by an incorrect type Dispose used battery according to the manufacturer instructions the Pet Mask the plastic pet mask if you do not require pet immunity Place your thumb at the base of the Pet Mask Place your fingers at the top of the Pet Mask Lift the Pet Mask to remove from Bracket Mount the bracket on the wall in the point marked F in the drawing and the cover from the base the battery while observing polarity OR If battery already installed remove the activation strip that from the front of the detector the cover to the base until a click is heard the is closed the detector with the screw the detector with the bracket the detector upward until a click is heard Release screw Separate the cover from the base Remove battery Press on the stopper snap to release the base from the bracket Slide the base downward to remove the alarm systems Installation Guide and follow the enrollment general description of the procedure is provided in the following flow chart Procedure the Installation Manual for the alarm system that the device is enrolled on to ensure that the proper steps are used the Device Enrollment option through the specified method select the appropriate option to add a new device the device by either holding the enroll button until the is detected or by entering the Device ID the desired Zone Number any device parameters that are required and test the detector See section 3 for information on testing device In addition see the alarm systems Installation Manual the device is enrolled on for other test procedures that are the detector is already enrolled you can configure the detector parameters programming the system see the alarm systems Installation Manual for information about device parameters Display instructions on displaying the temperature of zones on the control panel measured by PGx914 detectors see the alarm systems Installation Manual details Configuring the Detector Parameters the DEVICE SETTINGS menu and follow the configuration instructions the PGx914 detector as described in the following table Instructions whether or not the alarm LED indication will be activated settings LED ON default and LED OFF whether an alarm will be activated upon continued low sensitivity or upon a single alarm event high Optional settings LOW sensitivity default and HIGH whether or not the sensor is active when the system is Optional settings NOT Active while disarmed no delay 5s delay 15s delay 30s delay 1m delay delay 5m delay 10m delay 20m delay and 60m delay LOCAL DIAGNOSTICS TEST Run a diagnostic test at least once a week to ensure that the detector working correctly the base from the cover the cover to return the tamper switch to its normal position and then secure the front cover to the base with case closure screw PGx914 detector will enter a 2 min stability period During this time red LED blinks Walk test the coverage area Walk across the far end of the coverage in both directions The red LED lights each time your motion is followed by 3 LED Instruct the user to walk test at least once a week to verify functioning of the detector following table outlines received signal strength indication response LED blinks Strong LED blinks Good LED blinks blinks communication Reliable reception must be assured Therefore poor signal is not acceptable If you receive a poor signal from the device re it and re test until a good or strong signal strength is received UL ULC installations only STRONG signal level are acceptable comply with FCC and IC RF exposure compliance requirements the should be located at a distance of at least 20 cm from all persons normal operation The antennas used for this product must not be or operated in conjunction with any other antenna or dispositif doit plac une distance d moins 20 cm partir de les personnes au cours de son fonctionnement normal Les utilis pour ce produit ne doivent pas situ ou exploit avec une autre antenne ou transmetteur This equipment has been tested and found to comply with the limits a Class B digital device pursuant to part 15 of the FCC Rules These are designed to provide reasonable protection against harmful in a residential installation This equipment generates uses and radiate radio frequency energy and if not installed and used in with the instructions may cause harmful interference to radio However there is no guarantee that interference will not in a particular installation If this equipment does cause harmful to radio or television reception which can be determined by the equipment off and on the user is encouraged to try to correct interference by one or more of the following measures or relocate the receiving antenna the separation between the equipment and receiver the equipment into an outlet on a circuit different from that to the receiver is connected the dealer or an experienced radio TV technician for help a test et jug conforme aux limites s un num de classe B conform la Partie 15 des de la FCC Ces limites ont pour offrir une raisonnable contre les interferences nuisibles dans une installation g utilize et peut de l de fr et s n pas install et utilize conform aux instructions du peut provoquer des interf dangereuses pour les radio Toutefois rien ne garantit l d une installation particuli Si cet provoque des nuisibles au niveau de la r radio ou television ce qui determine par la mise hors puis sous tension de l vous invite essayer de corriger les interferences en pregnant les mesures R ou d l r Augmentez la distance qui s l et le r Branchez l

Related Files