DSC Wireless Zones PC1616 1832 1864 V4 2
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-wireless-zones-pc1616-1832-1864-v4-2-9147253086.pdf |
---|---|
Type | |
Size | 612.09 KB |
Downloads |
Text Preview
Notes Wireless Zones PC1616 1832 1864 V4.2 RF5132 433 RFK55XX SERIES PC1616 1832 1864 V4.2 wireless receiver can be used to connect up to 32 wireless detection devices Each wireless device a zone wireless zones is eight step process the zone definitions the zone attributes the zone assignments the Zone Serial Numbers Connect the wireless receiver to the KEYBUS Disabling the Supervision of Panic Zones Optional the Wireless Supervisory Window Optional a Module Placement Test Sections 001 002 101 132 202 261 804 01 32 804 82 85 804 81 904 01 32 Definitions Attributes Zone Assignment Serial Number Device Supervision Optional Supervisory Window Optional Placement Test 1 Connect the wireless receiver to the KEYBUS the four KEYBUS terminals of the wireless receiver to the four KEYBUS terminals of the main panel 2 Program the Zone Definitions wireless zones will operate on the system they must be defined the receiver is not connected to the KEYBUS the wireless data cannot be programmed 1 to 16 Definitions 17 to 32 Definitions Only the first 32 zones can be programmed as wireless Do not define wireless zones as 07 08 09 29 or 30 If using wireless smoke program zone definitions 87 or 88 Page 63 3 Program the Zone Attributes panel must be told which zones are wireless Turn Option 8 ON for all wireless zones in Sections 101 132 4 Partition Zone Assignment any zone will operate on the system the zone must be assigned to a partition Turn ON the correct option in the appropriate Section for all zones preset on the system 5 Enroll Wireless Devices the ESN number for each wireless detection device in Section 804 subsection 01 to 32 HEX digits may be present in the ESN number Use the following table to program the HEX 1 Zone Assignments Zones 1 to 32 2 Zone Assignments Zones 1 to 32 3 Zone Assignments Zones 1 to 32 4 Zone Assignments Zones 1 to 32 5 Zone Assignments Zones 1 to 32 6 Zone Assignments Zones 1 to 32 7 Zone Assignments Zones 1 to 32 8 Zone Assignments Zones 1 to 32 202 Section 205 210 Section 213 218 Section 221 226 Section 229 234 Section 237 242 Section 245 250 Section 253 258 Section 261 A B C D E F 1 2 3 4 5 6 6 Optional Disabling Supervision of Panic Zones wireless Panic Pendent WS4938 433 does not send a supervisory signal Supervision must be for these zones to prevent the panel from generating a zone fault trouble condition Turn the Option OFF in Section 804 subsection 82 to 85 for all wireless panic pendants zones 7 Optional Wireless Supervisory Window transmitters check in with the wireless receiver every 64 minutes The wireless supervisory window programmed in 15 minute increments For example data 32 8 hours data 96 24 hours Program desired supervisory window in Section 804 subsection 81 If a signal is not received from the a zone fault trouble will be generated Page 64 a tamper by removing the back plate then replacing it 8 Perform a Module Placement Test wireless transmitters must be tested To test a wireless transmitter enter Section 904 subsection 01 32 the zone to be tested Activate the device as indicated below Create restore a tamper by removing the cover then reattaching it down the test button until the WS4916 chips then squawks a magnet near groove marked on outer rim of bracket tamper by pressing the Tamper Tab for five seconds a tamper by removing the back plate then replacing it Placement Test is not available Test the unit by activating the Panic alarm from points throughout the installation to ensure proper reception an alarm or create restore a tamper Placement Test is not available Test the unit by activating the Panic alarm from points throughout the installation to ensure proper reception Placement Test is not available Test the unit by activating the Arm Disarm from points throughout the installation to ensure proper reception zone violations by removing for five seconds then securing for five seconds magnet to the reed switch zone violations by removing for five seconds then securing for five seconds magnet to the reed switch zone violations by removing for five seconds then securing for five seconds magnet to the reed switch zone violations by removing for five seconds then securing for five seconds magnet to the reed switch zone violations by removing for five seconds then securing for five seconds magnet to the reed switch at least 5 seconds between each test panel will indicate the test result on the keypad 1 indicates GOOD placement 3 indicates BAD placement is GOOD indicates GOOD placement is BAD indicates BAD placement keypads Keypads squawk of the siren indicates GOOD placement squawks of the siren indicates BAD placement The button on the WLS906 smoke detector is a local test only one transmitter tests BAD move the transmitter If several transmitters test BAD move RF5108 RF5132 or RFK55XX receiver Page 65 Tips When using zone expanders or addressable devices make sure the wireless detectors are not a zone already used on a PC5108 or as addressable The RF5132 433 will generate a Module Tamper if an RF Jam condition is detected To disable RF turn ON option 7 in Section 804 subsection 90 good placement tests cannot be received from a transmitter try moving the transmitter If there is problem with multiple detectors try moving the receiver the keypad gives a long error tone when a wireless subsection is entered it indicates the receiver not connected to the KEYBUS Test all wireless detectors and verify all are displayed on the keypad Page 66