DSC WLS906-433 - Installation Manual - English - Wireless Photoelectric Smoke Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-wls906-433-installation-manual-english-wireless-photoelectric-smoke-detector-1452763890.pdf |
---|---|
Type | |
Size | 772.96 KB |
Downloads |
Text Preview
Use six AA Alkaline Energizer E91 or Duracell MN1500 Do not use other brands of batteries for the detector Using brands other than the Energizer or Duracell MN1500 may affect the operation of system Replacement batteries may be purchased supermarkets and hardware stores the Unit the smoke detector mounting plate on the wall or and mark all desired screw locations Use the wall anchors for all screw locations When the have been placed secure the mounting plate to ceiling or wall place the smoke detector on its mounting plate align mounting plate s locking tab with the lock recess on case and turn the unit clockwise until it is firmly Insert the screw provided to secure the head mounting plate Select a smooth flat surface If the mounting is uneven the unit may generate a tamper fault EQUIPMENT SHOULD BE INSTALLED IN WITH THE NATIONAL FIRE ASSOCIATION STANDARD 72 Fire Protection Association 1 Batterymarch Quincy MA 02269 9101 Cover dust cover is intended to protect the unit from dust dirt entry while the unit is not in service The smoke detector will not function with dust cover in place Maintenance Instructions the Meridian smoke detector will not require If the unit is mounted in a dusty environment inlet areas of the case should be wiped gently with a dry cloth sure to inform the user and their monitoring station when of any sort is performed on the smoke detector any part of the alarm control system Always test smoke after maintenance If a smoke detector continues generate nuisance alarms even after maintenance return unit to your vendor for service Responsibility to the User is the installer responsibility to thoroughly instruct the on the operation testing and maintenance of their The installer should fully explain and demonstrate functions of the alarm control system and any equipment as smoke detectors connected to it The user should provided with all instruction sheets and manuals for system and any components connected to it Complete thorough instruction for the user is essential to ensure will obtain the greatest benefit from their system the user with complete operational information also benefit the installer through a reduction in service for nuisance alarms Warranty Security Controls Ltd warrants that for a period of twelve months from the date of the product shall be free of defects in materials and workmanship under normal use that in fulfilment of any breach of such warranty Digital Security Controls Ltd shall at option repair or replace the defective equipment upon return of the equipment to its repair This warranty applies only to defects in parts and workmanship and not to damage in shipping or handling or damage due to causes beyond the control of Digital Controls Ltd such as lightning excessive voltage mechanical shock water damage damage arising out of abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any all other warranties whether expressed or implied and of all other obligations or liabilities the part of Digital Security Controls Ltd Digital Security Controls Ltd neither assumes authorizes any other person purporting to act on its behalf to modify or to change this nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential loss of anticipated profits loss of time or any other losses incurred by the buyer in with the purchase installation or operation or failure of this product detectors that are a part of this system may not properly alert occupants of a fire for number of reasons some of which follow The smoke detectors may have been improperly or positioned Smoke may not be able to reach the smoke detectors such as when fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors not detect smoke from fires on another level of the residence or building fire is different in the amount of smoke produced and the rate of burning Smoke cannot sense all types of fires equally well Smoke detectors may not provide timely of fires caused by carelessness or safety hazards such as smoking in bed violent escaping gas improper storage of flammable materials overloaded electrical children playing with matches or arson if the smoke detector operates as intended there may be circumstances when there insufficient warning to allow all occupants to escape in time to avoid injury or death Digital Security Controls Ltd recommends that the entire system be completely tested a regular basis However despite frequent testing and due to but not limited to criminal or electrical disruption it is possible for this product to fail to perform as expected Information Changes or modifications not expressly approved by Digital Security Ltd could void the user authority to operate this equipment Compliance Statement Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment equipment generates and uses radio frequency energy and if not installed and used properly strict accordance with the manufacturer instructions may cause interference to radio and reception It has been type tested and found to comply with the limits for Class B device accordance with the specifications in Subpart of Part 15 of FCC Rules which are designed provide reasonable protection against such interference in any residential installation However is no guarantee that interference will not occur in a particular installation If this equipment cause interference to television or radio reception which can be determined by turning the off and on the user is encouraged to try to correct the interference by one or more of the measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on differ circuits necessary the user should consult the dealer or an experienced radio television technician for suggestions The user may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Television Interference Problems This booklet is available the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 Smoke Detector Residential Use FOR AND USE THIS INSTRUCTION SHEET THOROUGHLY INSTALLING AND OPERATING YOUR SMOKE DETECTOR DSC Meridian wireless photoelectric smoke detector many advanced design and technical features provide years of reliable operation It is important to the installation and operation instructions on this to ensure that the unit will function properly any detector will be rendered useless if it is not properly or located is very important that you understand how to test and your system Read the Instruction or User Manual your alarm system to familiarize yourself with the fire functions Be sure to test your system regularly by the test procedures described in your manual you should ever have problems operating or testing system and especially if there are problems with the alarm functions then contact your smoke detector or dealer immediately for service smoke detectors and alarm systems are designed to you of potentially dangerous situations no system can emergencies An alarm system is not a substitute for and property insurance you should always maintain insurance coverage the Smoke Detector Works shown in the illustration a light source is directed the smoke chamber and is not normally reflected the sensing element When smoke enters the the light beam is scattered by the smoke and into the sensor When enough light is detected the sensor an alarm is activated On alarm the is activated and the red LED will flash When the clears from the smoke chamber the unit will reset itself minutes minutes Trouble minutes Trouble transmission Trouble Indications smoke every s every s every s self test normally self