DSC WLS914 - Installation Manual - English - Wireless Pet-Immune Passive Infrared Motion Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | dsc-wls914-installation-manual-english-wireless-pet-immune-passive-infrared-motion-detector-7903145268.pdf |
---|---|
Type | |
Size | 747.12 KB |
Downloads |
Text Preview
Battery Installation This system is designed to work with Eveready Energizer Batteries Do not install any other The reliability of the security system depends on its and name or generic brand batteries may provide the best quality and dependability Use fresh batteries Most batteries have a before printed on their packaging or on the batteries them Buy batteries that have a before date of two or more from your purchase date When disposing of used batteries follow the instructions precautions printed on the batteries Many cities and have collection sites or services for used batteries Contact your municipal offices for on the disposal of used batteries the motion detector from its mounting plate by holding the sensor by its and pushing up Install four fresh Eveready Alkaline Energizer AA batteries Be to insert the batteries in the proper orientation Replace the sensor on its mount plate making sure it snaps into place After the batteries are installed the detec will take 60 seconds to warm up During this time the LED will flash Compliance Statement Changes or modifications not expressly approved by Digital Security Controls Ltd could void your authority use this equipment equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance with manufacturer instructions may cause interference to radio and television reception It has been type tested and found comply with the limits for Class B device in accordance with the specifications in Subpart of Part 15 of FCC Rules are designed to provide reasonable protection against such interference in any residential installation However there no guarantee that interference will not occur in a particular installation If this equipment does cause interference to tele or radio reception which can be determined by turning the equipment off and on the user is encouraged to try to cor the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Television Interfer Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 Warranty Security Controls Ltd warrants that for a period of twelve months from the date of purchase the product shall be of defects in material and workmanship under normal use and that in fulfilment of any breach of such warranty Digital Controls Ltd shall at its option repair or replace the defective equipment upon return of the equipment to its repair This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling damage due to causes beyond control of Digital Security Controls Ltd such as lightning excessive voltage mechanical water damage or damage arising out of abuse alteration or improper application of the equipment foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties whether or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd This warranty contains entire warranty Digital Security Controls Ltd neither assumes nor authorizes any other person purporting to act on its to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product no event shall Digital Security Controls Ltd be liable for any direct indirect or consequential damages loss of anticipated loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or of this product Dual PIR Motion Detector INSTRUCTIONS WLS914 is a specialized PIR motion detector using 2 dual element PIRs and immunity from false alarms caused by pets The WLS914 is equipped a specially designed lens which enables the detector to discriminate between and small to mid sized pets Signal Processing temperature compensation and large multi beam lens mean the human target will not slip by unnoticed even on a hot summer day WLS914 with its 5 year warranty is your assurance of a trouble free installation Power requirement 4AA alkaline batteries supplied Operating temperature 32oF to 122oF 0oC to 50oC Operating humidity 5 to 85 RH non condensing Static immunity 10 kV Walk detection speed 0.5ft s to 10ft s 0.15m s to 3m s Coverage angle wall wall lens 100o maximum Mounting heights 7.5ft 2.3m Dimensions 4.9 H x 2.8 W x 2.7 D 124.5mm x 70mm x 67mm Color white with white lens a Mounting Location motion detector should be located so that it provides optimal coverage of the to be protected When selecting locations for motion detectors observe the The mounting height should be 7.5 ft 2.3 m Do not aim the detector at a stairway which a pet has access to Do not place that pets can climb on higher than 3 ft 0.9m closer than 6 ft 1.8m to detector e g a cat on a couch Do not aim the detector at reflective surfaces such as mirrors or windows This distort the coverage pattern or reflect sunlight directly onto the detector locations where the detector may be exposed to direct or reflected sunlight Avoid locations that are subject to direct air flow such as near an air duct outlet Do not locate the detector near sources of steam or oil vapor such as a stove or fryer Do not obscure the detector coverage pattern with large objects within the area If you can see the detector it can see you For indoor use only Dead zone 6 cm Digital Security Controls Ltd Canada Line 1 800 387 3630 in Canada 29004697 R002 Patented Protected by one or more of the following patents 2099971 US 5444432 Lens View View the WLS914 the back of the PIR housing there will be two serial numbers a five digit num and a six digit number Please refer to your receiver installation manual for on which serial number should be enrolled If using a WLS900 system you must use the five digit serial number No detector should be mounted without first performing a module test to determine that it is in range of the wireless receiver the Placement Test instructions in the Instruction Sheet for your or in the installation manual for your system you have selected a location the detector from the backplate with one hand hold the sides of the and with your other hand push down on the top of the backplate the plastic knockouts from the back mounting holes the backplate on the wall in the selected location and mark the screw loca It is suggested that wall anchors be used all screw locations the backplate to the wall the enrolled detector to its backplate Motion Detector Sensitivity motion detector features Fast and Slow detection modes are set on jumper J1 Jumper J1 is set at the factory for Fast detection mode In a normal operating environment setting provides the best detection certain environments where rapid air movement heaters other variables present problems use Slow detection to stabilize the detection diagram on the right shows the jumper location To open case use a small flat blade screwdriver and gently push in the tab at the bottom the case and pull the cover straight out at the bottom To change the setting from to Slow remove the jumper Refer to the PC5132 and PC5010 Installation Instructions for UL requirements For UL ULC installations where the WLS914 is used on or exit delay zones the entry delay must not be longer than 39 sec and the exit delay must not be longer than 54 seconds Traffic shutdown Mode prolong battery life the motion detector uses a feature called High Traffic Shut When motion is detected the device will transmit to the receiver and will then down for three minutes If motion is detected again during the shutdown time unit will not transmit the event to the receiver The detector will thus remain in shutdown mode until three minutes after the first motion detected was transmit The detector will transmit detected mot