DSC WS4904P - Installation Manual - English Spanish French - Wireless Pet-Immune Passive Motion Detector

File Preview
File Preview
Click below to download for free

Text Preview

WS4904P Installation Instructions d WS4904P de Instalaci WS4904P Installation Manual shall be used in conjunction with the Installation Manual of the DSC wireless receiver and control panel with which device is intended to be used WS4904P detector is designed to combine the convenience of a wireless detector with effective and reliable detection of human motion well as good protection against the nuisance alarms associated with pets weighing up to 60 lbs 27.3kg the Detector WS4904P detector provides effective immunity to single or multiple pets whose total combined weight does not exceed 60 lbs 27.3kg installed and configured in the following manner a detector location that will provide the coverage required and will allow the detector to be mounted a minimum of 6 ft 1.95m and not higher than 10ft 3m 7 ft 2.3m recommended the following to avoid false alarms Do not aim the detector at a stairwell to which a pet has access Do not place furniture or objects higher than 3ft 0.9m which a pet can climb onto e g a cat on a couch closer than 6ft 1.8m the detector in conjunction with pets onto the detector Mount the detector flat on a wall or in a corner Do not angle it downwards or use mounting brackets with this detector when it is Do not aim the detector at reflective surfaces such as mirrors or windows as this may distort the coverage pattern or reflect sunlight Avoid locations that are subject to direct high air flow such as near an air duct outlet Do not locate the detector near sources of moisture such as steam or oil Do not limit the coverage by large obstructions in the detection area such as plants or cabinets For indoor use only non hazardous locations No detector should be mounted without first performing a module placement test to determine that it is in range of the wire receiver See the Placement Test instructions in the Instruction Sheet for your receiver or in the Installation Manual for your sys a location has been selected remove the plastic from the mounting holes and locate the backplate on the wall and mark locations It is suggested that wall anchors be used for all screw locations Secure the backplate to the wall and then secure enrolled detector to its backplate Use only backplates marked as Using any other backplates will result in the tamper switch being broken a WS4904P the back of the PIR housing there will be a six digit number the Sensitivity Setting WS4904P features and settings on jumper JP1 which is used to configure the detector for the weight of the pet s and environment For an environment with a single pet whose weight does not exceed 30lbs 13.6kg the jumper should be set to set In an environment with single or multiple pets whose combined weight is greater than 30lbs 13.6kg but not greater than 60 lbs the jumper must be set to the setting When the detector is mounted 6 ft to 7 ft high 1.95 to 2.3 m or there is the of the pet getting higher than 4ft 1.2 m the slow setting must be used To change the setting from Slow to Fast move the over one pin as shown in the diagram Traffic Shutdown Mode prolong battery life the motion detector uses a feature called High Traffic Shutdown When motion is detected the device will transmit to receiver and will then shut down for three minutes If motion is detected again during the shutdown time the unit will not transmit the to the receiver The detector will thus remain in the shutdown mode until three minutes after the first motion detected was transmitted detector will transmit detected motion every three minutes High Traffic Shutdown Mode affects testing the motion detector in two ways performing the module placement test the unit must be tampered by removing the unit from the backplate and replacing it The place test cannot be performed by creating motion in front of the device performing a system test the unit must be left idle for three minutes before testing can be performed Once three minutes has passed cre motion in front of the detector to see if the device is both detecting motion and transmitting to the receiver Refer to the PC5132 RF5132 433 RF5501 or the System Installation Instructions for UL ULC requirements For UL ULC where the WS4904P is used on entry or exit delay zones the entry delay must not be longer than 45 seconds and the delay must not be longer than 60 seconds Detector Transmission Delay motion detector transmission is always delayed by six seconds This is necessary to prevent false alarms caused by a motion sensor trans before a delay zone has a chance to report This six second delay cannot be altered or disabled Test Mode motion detector has a walk test mode which will activate an LED for testing purposes During normal operation the LED will not turn on To the detector in walk test mode create a tamper by removing the detector from its backplate and then replacing it Each time the detector motion it will flash the red LED Six seconds after motion is detected the detector will send a signal to the receiver The detector will be in test mode until it has sent 10 transmissions verify the pet immunity of the detector place the animal s within the coverage area and then move out of the zone Encourage the pet to move as it normally would and ensure that it moves across the detection pattern of the detector Verify that no alarm is initiated To test for catch of humans create motion in the entire area where coverage is desired by walking perpendicular to the lens pattern Should the cov be incomplete readjust or relocate the detector Pet Immunity not verified by UL The Walk Test Mode will override the High Traffic Shutdown Mode manuel d doit utilis en conjonction avec le manuel d du r sans fil DSC et du panneau de contr pour ce dispositif a con WS4904P d est con pour combiner la commodit d d sans fil avec la d efficace et fiable du mouvement humain et bonne protection contre la nuisance des fausses alarmes li des animaux domestiques pesant un maximum de 27,3 kg 60 lbs du d WS4904P offre une immunit efficace contre un ou plusieurs animaux domestiques dont le poids total ne d pas 27,3 kg 60 lbs lorsqu est et configur comme suit un emplacement qui offrira la couverture requise et permettra au d d install une hauteur minimum de 1,95m 6,5 pi et de 3m 10 pi 2,3 m 7,5 pi recommand Tenez compte des suivants pour les fausses alarmes Ne placez pas le d face un escalier auquel un animal domestique a acc Ne placez pas de meuble ou d d hauteur de plus de 0,9 m 3 pi sur lequel un animal domestique peut grimper par ex un sur un sofa moins de 1.8 m 6 pi du d Installez le d plat sur un mur ou dans un coin Ne l pas vers le bas et n pas de support de montage lorsque ce est utilis et que des animaux domestiques sont pr Ne placez pas le d en face de surfaces r telles que des miroirs ou des fen car elles pourraient d le dia de rayonnement ou r la lumi solaire directement sur le d les emplacements o le d pourrait expos un courant d intense comme une sortie de gaine de circulation d Ne placez pas le d pr de sources d telles que de la vapeur d ou d Ne limitez pas la couverture en pla des objets importants dans la zone de d telles que des plantes ou des armoires Pour utilisation int seulement N d aucun d avant d fait un essai de placement de module pour d s se trouve dans port du r sans fil Voir les instructions d d dans la Notice d de votre r ou dans le Man d de votre syst emplacement a trouv retirez le plastique des trous de montage placez la plaque arri sur le mur et marquez l des vis vous sugg d des ancres pour toutes les vis Fixez la plaque arri au mur puis fixez le d sur sa plaque arri Utilisez seulement une plaque arri identifi Si vous utilisez n quelle autre plaque arri vous endommag l

Related Files