DSC WS4913 Installation Instructions - Eng

File Preview
File Preview
Click below to download for free

File Data

Name dsc-ws4913-installation-instructions-eng-3072549186.pdf
Type PDF
Size 857.54 KB
Downloads

Text Preview

WS4913 Series Wireless Monoxide Alarm Installation and Operating Instruction Manual shall be left with the User of this equipment product is intended for INDOOR USE Non hazardous locations ONLY this instruction sheet thoroughly before installation and of the WS4913 wireless carbon monoxide alarm WS4913 is a wireless electrochemical Carbon Monoxide alarm is effective for detecting any buildup of carbon monoxide also as CO gas in your home or office Your CO alarm includes the features See figure 1 as below Easy to install Continuous monitoring for presence of carbon monoxide A loud 85 dB alarm when a buildup of carbon monoxide is detected A test button to provide visual and audible indication that the unit is Self diagnostics to immediately indicate any troubles Seamless integration with DSC controls panels using the panel bell Compliant with the requirements of UL Standard 2075 and system keypad to annunciate carbon monoxide build up or device troubles cid 691 cid 691 cid 691 green LED flashes approx once every 60 seconds indicating that the has power and is actively sampling the carbon monoxide level in air During the first 5 minutes after inserting the battery the orange LED flash every 10 seconds and the unit will chirp every 60 seconds to that the unit is in warm up mode alarm CO alarm will go into alarm when the concentration of carbon CO in the air around the device exceeds the threshold an alarm the red LED light flashes rapidly and buzzer sounds with 4 quick beeps and pause 5 seconds and then 4 quick beeps 4 minutes of being in alarm the pause between beeps will change to seconds The alarm will continue to sound until the concentration of CO the air around the CO alarm drops below the threshold or the button is pressed When properly enrolled on a DSC control panel which supports the Wireless Carbon Monoxide Alarm the CO alarm will be communicated to the control panel The control panel will then the CO alarm using the control panel bell output and display alarm and zone number which generated the alarm on the system At the same time the control panel will communicate the alarm the central station to dispatch the appropriate authorities Please refer your control panel installation manual for details cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 691 cid 708 cid 691 removal of the CO alarm from the mounting plate initiates a built in sounder on the WS4913 will chirp once per minute and the LED will be ON steady the unit on the mounting plate will restore the tamper condition properly enrolled on a DSC control panel the Tamper will be Please refer to the PC9155 433 cid 691 panel Installation Manual details Battery The WS4913 is powered by a 3 V DC Duracell Ultra DL123AB battery WARNING Use only the batteries as specified above Use a different battery may have a detrimental effect on alarm Installing Replacing battery See figure 2 as below Open the battery cover to expose the battery compartment Remove the old battery and properly dispose of it as recommended by battery manufacturer Note the polarity of the battery and ensure it is correctly installed as the polarity markings indicated on both sides of the battery make sure to carefully seat the red battery warning flag the recess of the battery compartment Gently close the battery cover The battery cover of CO alarm will not if the battery is not properly installed Caution Constant exposures to high or low temperatures or humidity may reduce battery life carbon monoxide alarm is designed to detect carbon monoxide gas ANY source of combustion It is NOT designed to detect smoke or any other gas unless the product has been investigated and to comply with the applicable requirements WS4913 has been designed to ensure that there is at least 30 days battery life remaining once the battery condition has been and transmitted to the DSC control panel the battery voltage is low the built in sounder on the WS4913 will once every 60 seconds and the yellow LED will flash once per until battery failure When properly enrolled on a DSC control the Battery will be annunciated on the system keypad and the will show as being in Fault Please refer to the panel Installation for details Replace the battery as soon as possible after low indication is provided Conditions the WS4913 self diagnostics function detects a trouble condition it will be by the trouble indicator LED Malfunction Error mode The yellow LED flashes 3 times and the in sounder chirps once every minute This trouble indicates an internal and the unit will need to be replaced Low sensitivity mode The yellow LED flashes 2 times and the built in chirps once every minute This trouble indicates an internal fault the unit will need to be replaced End of life signal mode The yellow LED flashes 4 times and the built sounder chirps once every minute This indicates that the WS4913 CO is reaching the end of this useful life around 6 years after the unit purchased please replace with a new WS4913 CO detector properly enrolled on a DSC control panel the condition will annunciated on the system keypad Please refer to the PC9155 433 Installation Manual for details to install your CO alarm CO gas moves freely in the air the suggested location is in or as as possible to sleeping areas of the home The human body is most to the effects of CO gas during sleeping hours For maximum a CO alarm should be located outside primary sleeping areas on each level of your home Figure 3 below indicates the suggested in the home The electronic sensor detects carbon monoxide the concentration and sounds a loud alarm before a potentially level is reached 3 Location for placing CO in a multi floor not place the CO alarm in the following areas Where the temperature may drop below 4.4 cid 845 cid 726 or exceed 37.8 cid 845 cid 726 cid 705 cid 691 Near paint thinner fumes Within 5 feet 1.5 meter of open flame appliances such as furnaces and fireplaces exhaust streams from gas engines vents flues or chimneys Do not place in close proximity to an automobile exhaust pipe this damage the Alarm Keep the CO alarm away from excessively dirty dusty or greasy such as kitchens and garages Ensure adequate ventilation using household cleaners and chemicals as these can affect sensor the CO Alarm WS4913 CO alarm is easy to install to protect you and your family in home cottage cabin and or office To install the CO alarm See figure 4 as below 1 For a wall mounted location the detector should be at least six from the ceiling for a ceiling

Related Files