WS4938 2W Wireless Panic Button Instructions WS4938 2W Wireless Panic Button was designed to transmit an signal from any location within the range of the alarm system if the system is armed or disarmed button is small and lightweight enough to be placed in a shirt pocket or away inside a purse It can also be used with the supplied neck or multi functional clip which can connect to your belt car visor or be mounted to a convenient location activate press and hold the 2 buttons for approximately 2 seconds LED located on the top of the unit will light up to confirm a signal has sent Signals will not be received if the button is not within range of the wireless receiver Enrolling and Programming conserve battery power the button comes deactivated To activate simply the cover and slide the switch to the ON position to the left device is supervised If the unit is removed from the coverage range a trou will be indicated on the system If this is not desired the supervisory bit for zone can be disabled on the receiver following outlines the basic steps for programming and enrolling this on PowerSeries receivers additional options or for other receivers please refer to the specific installation manuals 1 Program Electronic Serial Number ESN 804 subsections 01 32 Zone 1 32 Zone 32 the 6 digit ESN located on the back of the device into the next available zone slot 2 Program Zone Definition 001 004 the selected zone number with appropriate zone type e g 24hr Panic 16 Holdup 12 24hr Medical 15 3 Enable Wireless Zone Attribute 101 132 Option 8 ON wireless zone attribute in corresponding zone attribute section 4 Enable Disable Supervision default is enabled 804 subsections 82 85 Wireless Zone Supervision Zones 1 8 ON Option 1 Zone 01 Supervision Enabled Disabled ON OFF Option 8 Zone 08 Supervision Enabled Disabled Wireless Zone Supervision Zones 9 16 Wireless Zone Supervision Zones 17 24 Wireless Zone Supervision Zones 25 32 WS4938 2W is compatible with the following receivers PC4164 433 v3.00 or greater cid 129 PC5132 433 v4.2X or greater RF5501 433 cid 129 RF5108 433 cid 129 NT9005 the Batteries normal conditions the batteries can last up to 2 years If the is low the trouble light on the keypad will turn ON replace the batteries remove the top cover by inserting a coin the slot located on the bottom right corner and twist Remove screw at the center of the board to expose the batteries both batteries with Panasonic CR 2025 lithium batteries diagram NT9005 v1.02 requires that the serial number of the WS4938 2W be deleted and re in order to restore the low battery The polarity of the battery must be observed as shown in the diagram above Improper of lithium batteries may result in heat generation explosion or fire which may lead to injuries Danger of explosion if batteries are installed incorrectly Replace only with same or equivalent type recommended by the manufacturer Keep away from small If Batteries are swallowed promptly see a doctor Do not try to recharge these Disposal of used batteries must be made in accordance with the waste recovery recycling regulations in your area Clip Assembly and Mounting 32 to 120 0 to 49 5 93 RH Water resistant Digital Security Controls Toronto Canada www dsc com in Taiwan

Related Files