Push the tab screwdriver Instructions Mounting the WS4965 the WS4965 in Reed Switch Mode Place the mounting bracket in the position determined in the Enrolling Pro Placement step Secure the bracket to the door frame using the two provided See Figure B the sensor in place To release bracket Remove the front cover Push the tab see Figure B with a screwdriver and slide the WS4965 down Align one end of the magnet with the notch on the side of WS4965 housing Figure A Mount the magnet a maximum of 1 2 1.27cm from the WS4965 using screws provided If necessary use the spacers provided See Figure C Mount magnet Open and close the door window to ensure that there is no Only one magnet can be used for each WS4965 The contact shall installed so that a door or window cannot be opened more than 2 51 mm without causing an alarm condition 1.27 CM CM Bracket B the WS4965 in Tilt Switch Mode Jumper 3 JP3 for switch operation the tilt switch to be in the closed position mount the WS4965 in the vertical position with the battery located on the bottom Once the garage is open the tilt switch will activate and generate a transmission See Figure D WS4965 can be programmed to wait 1 minute after the tilt switch activates before it transmits the alarm This is useful for the garage doors require longer entry delay time To program this feature remove Jumper 2 JP2 The reed switch is deactivated when using the tilt function carefully moving the tilt switch up or down the degree of motion required to cause an alarm can be adjusted not permanently mount the WS4965 until the Placement Test has been successfully passed This mode is not to be used in UL listed installations External Contacts The WS4965 has 2 normally closed contact terminals These can be used for additional hardwired wired contacts or other dry con switches Connect the external devices to the contact terminals as per the manufacturers instructions The maximum wire run from the external con must not exceed 25ft 7.6m UL Installation the external contacts and WS4965 must be in the same room Testing Verify Sensor operation Tamper operation and Supervisory Operation Operation of these features is explained below Operation Tamper Switch The WS4965 comes equipped with case tamper detection If the cover is removed the WS4965 will report a zone tamper to the panel Upon tamper all 3 serial numbers will report a tamper transmission Supervision The WS4965 sends a periodic supervisory transmission to the panel If the panel fails to receive a transmission within the prepro period refer to receiver manual for supervisory window it will indicate a fault on the keypad All three serial numbers will transmit a supervisory signal to the receiver Low Battery LED Indicator There is a low battery LED indicator on the WS4965 It will flash at 10 second intervals when a low battery con is detected and transmitted to panel This will provide visual identification of the unit that requires a battery change Battery Replacement The WS4965 requires one CR123A lithium battery To replace the battery remove the cover by pressing on the end and it up Use care when installing the battery and observe the correct polarity Dispose of used battery promptly Keep away from children Do disassemble and do not dispose of in fire The battery used in this device may present a fire or chemical burn hazard if mistreated Do not recharge disassemble heat above 212 or dispose of in fire Replace battery with Panasonic CR123A only Use of another battery may present a risk of fire or explosion Battery may explode if mistreated Do not recharge disassemble or dispose of in fire with NO Spacer WITH Spacer C SWITCH MAKING D SWITCH Closed ID F5305WS4965 device complies with Part 15 of the FCC rules Operation is subject to the following conditions 1 This device must not cause harmful and 2 must accept any interference received including interference that may cause undesired operation 160A WS4965 The term before the radio certification number only signifies that Industry Canada technical specifications were met Digital Security Controls Canada www dsc com Support Canada US 905 760 3036 in Taiwan WS4965 is a 3 zone device The primary zone can be configured as a traditional normally closed door window contact with supplied magnet If the device magnet combination is inconvenient it can be configured for normally closed tilt switch operation for overhead doors The WS4965 also 2 normally closed contact inputs Dimensions 75mmx43mmx25mm 2 15 16 x 1 11 16 x 1 Operating Temperature 10 to 49 14 to 120 Operating Humidity 5 93 RH UL ULC Listed for residential use only with PC5132 433 PC4164 433 NT9005 433 RF5501 433 RF5108 433 Select Operating Mode Remove the cover by pressing on the end notch to lift top cover Ensure that the jumpers 1 2 and 3 are as follows Operating Frequency 433MHz Battery Panasonic CR123A Lithium Battery Life 5 8 years Not tested by UL ULC Switch mode Switch mode IN JP1 must always be IN NA No effect in Reed Switch operating mode IN JP1 must always be IN IN No delay OUT 1 minute delay before sending an alarm OUT IN Install Battery Use care when installing the battery and observe the correct polarity see Figure A Use only the Panasonic CR123A lithium battery Position Transmitter Select the location where the WS4965 is to be mounted RF signals can be affected by metal objects including metal doors or large mirrors Ensure that these types of objects are not located between device and the receiver as it can interfere with the proper operation of the WS4965 Enrolling Programming and Placement The three zones of the WS4965 have unique serial numbers The 6 digit serial number located on device is for the reed or tilt switch zone The serial numbers for the second and third zone i e external contacts inputs is the serial number located on 1 for Zone 2 and the serial number 2 for Zone 3 as indicated below Serial number printed on the WS4965 is 211117 or Tilt switch zone 211117 2 211118 3 211119 the last digit is a letter use the following sequence A B C D E F A 1 B A 2 C etc following steps outline the basic programming and enrollment of this device when used with PowerSeries receivers For additional options or for receivers refer to the specific receiver Installation Manual 1 Program Electronic Serial Number ESN Section 804 subsections 01 32 Zone 1 32 Zone 32 the 6 digit ESN located on the back of the device into the next available zone slot Example ESN 211117 zone contact zone contact zone 1 2 3 2 Program Zone Definition Section 001 004 corresponding zone with appropriate zone type Ex Delay 01 Instant 03 etc 3 Enable Wireless Zone Attribute Section 101 132 Option 8 ON wireless zone attribute in the corresponding zone attribute section wireless devices must be tested for good signal strength from where they are Test wireless device signal strength from the final mounting position 4 Module Placement Test Section 904 subsections 01 32 JP2 JP1 CM COM Z3 A a transmission by moving the magnet away from the WS4965 or by activating tilt sensor panel will sound the siren and light LED 1 or 3 to indicate the test result squawk of the siren or keypad LED 1 indicates GOOD placement squawks of the siren or keypad LED 3 indicates BAD placement the transmitter tests BAD move the transmitter and repeat the Placement Test until 3 GOOD results in a row are indicated Door Window Contact 1.0 the tab screwdriver Instructions Mounting the WS4965 the WS4965 in Reed Switch Mode Place the mounting bracket in the position determined in the Enrolling Pro Placement step Secure the bracket to the door frame using the two provided See Figure B the sensor in place To release bracket Remove the front cover Push the tab see Figure B with a screwdriver and slide the WS4965 down Align one end of the magnet with the notch on the side of WS4965 housing Figure A Mount the magnet a