DSC WS4985-WS8985 Installation Instructions - Eng Ger

File Preview
File Preview
Click below to download for free

File Data

Name dsc-ws4985-ws8985-installation-instructions-eng-ger-1659827430.pdf
Type PDF
Size 1.34 MB
Downloads

Text Preview

WS4985 WS8985 Instructions Installationsanleitung Deutsch WS8985 One Way Wireless Detector Installation Instructions 2 2 WIRE 1 Probes 2 Mounting Mounting this installation sheet with the associated DSC receiver and control installation manual All specified within manuals must be WS4985 is a one way wire flood detector intended use with compatible DSC Systems Multiple WS4985 WS8985 flood detec can be enrolled on and supervised by the same security up to the maximum number of zones supported by panel The flood detector consists of a water sensor and wireless transmitter that are connected by a 1.82m 6ft cable This device continuously monitors for unaccept water levels If water is detected e g when both are in contact with the water the WS4985 wirelessly communicates this alarm condition to control panel receiver Humidity Frequency Temperature 10 to 55 14 to 131 R H max Transmitter Only WS8985 Only Life Receivers Transmitter Only Lithium Panasonic or Duracell years under typical use SCW9045 47 433 868 PC4164 and PC9155 of Box water sensor and wireless transmitter pack Installation sheet Locate and Operate WS4985 WS8985 comes with the battery pre To activate it hold the WS4985 WS8985 trans firmly in one hand and pull the plastic tab in the indicated Then select the locations where the and sensor will be mounted For detailed opera of your alarm system refer to the Alarm System user Program and Place one way wireless flood detector must be enrolled on the panel before it can transmit system events supervi signals or provide the local WS4985 WS8985 status case and wall tamper switch state battery state and cut state The following outlines the basic steps for pro and enrolling this device on PC9155 series secu panels For additional options or for other systems refer to the specific receiver or security system instal manuals 1 Enrolling WS4985 WS8985 flood detector can be enrolled by Enroll or manually by Serial Number Programming one of the following Enroll 1 7 Enter 8 Installer Code 898 on the system key Place the Flood Detector near the Control panel Tamper the WS4985 WS8985 by opening the transmit The Keypad displays the ESN electronic serial number housing to confirm it Select the zone number the device will occupy Select the zone type the device will follow 24hr Water is The electronic serial number is a 6 digit alphanu number located on a sticker on the wireless device Repeat Steps 2 to 6 to enroll additional WS4985 Number Programming 1 6 Enter 8 Installer Code on a system keypad Enter 804 to enter ESN electronic serial number pro Enter the desired subsections 001 032 e g 001 1 032 zone 32 Enter Enter the 6 digit ESN on the back of the in the next available zone slot Repeat Steps 3 and 4 to enroll additional devices Press to exit the current programming section 2 Program Zone Definition Enter Section 001 002 Assign the corresponding zone with the appropriate zone 19 24hr Water All wireless devices must be tested for good signal from where they are positioned 3 Device Placement Test Enter Section 904 To start the test open the wireless transmitter housing 3 or short the probes of the water sensor with a It is recommended that you placement test the detector with the water sensor connected There is a 3 to 5 second delay until an alarm is sent the device The control panel is programmed to respond with 1 beep the location is and 3 beeps if the location is If the location is change locations and Step 2 Mounting the proper location for the device is determined the can be permanently mounted The installer is responsible for ensuring that the is securely mounted in the intended location 2 Flood Detector locating metal Sensor water sensor must be mounted so both probes of the are touching water when an alarm condition is The water sensor should be mounted at low spots water will first accumulate e g floor Secure the sensor to the mounting surface with the screws pro There are mounting holes for wall and floor surfaces you are installing the device in these locations Figure 2 the sensor wire to the transmitter see Wireless section below Avoid mounting the transmitter portion of the behind a metal object such as a washing machine or freezer RF signals can be affected by objects After every flood detection each flood detector be cleaned and dried Otherwise the unit may not as intended due to the nature of different liquids After water has been cleared from the sensor head alarm restoral time is approximately 1 minute Transmitter the backplate from the transmitter Figure 3 Using Provided Screws Mount the back of the transmit with them Using Adhesive Tape Ensure you are attaching the wire transmitter to a painted and primed surface If sur conditions are unsuitable secure the transmitter the mounting screws provided external contact terminals of the transmitter are used to the sensor wire Figure 4 Ensure that all wiring is to 6mm 1 4 max and does not touch any of the The sensor wire can be cut to length for the fit Wire clamps should be used to keep the wire snug the wall Ensure that the sensor wire is laid out in such a that accidents cannot occur Connected cables must not subject to excessive mechanical strain Once the is installed test the water sensor to ver it activates in the event of an alarm condition Switch of the box the WS4985 WS8985 transmitter comes with transmitter case tamper detection If the trans case is removed the WS4985 WS8985 will report a tamper to the control panel For added security the was designed to provide wall tamper mon as well Simply replace the short rubber actuator Figure with the longer one that is included With this option if the is opened or if the WS4985 WS8985 is removed from it s a tamper will be sent to the control panel It is recommended that mounting screws be used when the wall tamper option If the sensor wire is cut the WS4985 WS8985 a tamper event to the control panel Test the unit at least once yearly Replacement replace the battery insert a flathead screwdriver into side of the transmitter and carefully twist to separate top and bottom plastic Figure 3 Once separated the will be visible Figure 4 Remove the old battery install the new battery Ensure the correct polarity is Disposal of used batteries must be made in accor with the waste recovery and recycling regulations in area Caution The battery used in this device may a fire or chemical burn hazard if mistreated Do not disassemble heat above 100 212 or dis of in fire Replace battery with one 3V lithium battery CR2 or Duracell CR2 only Use of another battery present a risk of fire or explosion Dispose of the used as per local regulations Keep away from children Switch Contact Terminals Tamper 3 Cover 4 Battery 5 Tamper Warranty Security Controls warrants that for a period of 12 months from the of purchase the product shall be free of defects in materials and

Related Files