DSC WS8904P Installation Sheet

File Preview
File Preview
Click below to download for free

File Data

Name dsc-ws8904p-installation-sheet-9756318240.pdf
Type PDF
Size 967.51 KB
Downloads

Text Preview

WS8904P Installation Instructions d WS8904P de Instalaci WS8904P Mount the detector flat on a wall or in a corner Do not angle it downwards or use mounting brackets with this detector when it is used in Ne placez pas le d en face de surfaces r telles que des miroirs ou des fen car elles pourraient d le diagramme de rayonne es usado en conjunto con mascotas Installez le d plat sur un mur ou dans un coin Ne l pas vers le bas et n pas de support de montage lorsque ce d est utilis 6 pies 1.8m desde el detector de 1.8 m 6 pi du d que des animaux domestiques sont pr Installation Manual shall be used in conjunction with the Installation Manual of the DSC wireless receiver and control panel with which this device intended to be used WS8904P detector is designed to combine the convenience of a wireless detector with effective and reliable detection of human motion as well as protection against the nuisance alarms associated with pets weighing up to 60 lbs 27.3kg the Detector WS8904P detector provides effective immunity to single or multiple pets whose total combined weight does not exceed 60 lbs 27.3kg when and configured in the following manner a detector location that will provide the coverage required and will allow the detector to be mounted a minimum of 6 ft 1.95m high and not than 10ft 3m 7 ft 2.3m recommended the following to avoid false alarms Do not aim the detector at a stairwell to which a pet has access Do not place furniture or objects higher than 3ft 0.9m which a pet can climb onto e g a cat on a couch closer than 6ft 1.8m from the with pets detector Do not aim the detector at reflective surfaces such as mirrors or windows as this may distort the coverage pattern or reflect sunlight directly onto Avoid locations that are subject to direct high air flow such as near an air duct outlet Do not locate the detector near sources of moisture such as steam or oil Do not limit the coverage by large obstructions in the detection area such as plants or cabinets For indoor use only non hazardous locations No detector should be mounted without first performing a module placement test to determine that it is in range of the wireless receiver the Placement Test instructions in the Instruction Sheet for your receiver or in the Installation Manual for your system a location has been selected remove the plastic from the mounting holes and locate the backplate on the wall and mark screw locations It is that wall anchors be used for all screw locations Secure the backplate to the wall and then secure the enrolled detector to its backplate Use only backplates Using any other backplates will result in the tamper switch being broken a WS8904P the back of the PIR housing there will be a six digit number the Sensitivity Setting WS8904P features and settings on jumper JP1 which is used to configure the detector for the weight of the pet s and the environ For an environment with a single pet whose weight does not exceed 30lbs 13.6kg the jumper should be set to setting In an environ with single or multiple pets whose combined weight is greater than 30lbs 13.6kg but not greater than 60 lbs 27.3kg the jumper must be set the setting When the detector is mounted 6 ft to 7 ft high 1.95 to 2.3 m or there is the possibility of the pet getting higher than 4ft m the slow setting must be used To change the setting from Slow to Fast move the jumper over one pin as shown in the diagram Traffic Shutdown Mode prolong battery life the motion detector uses a feature called High Traffic Shutdown When motion is detected the device will transmit to the recei and will then shut down for three minutes If motion is detected again during the shutdown time the unit will not transmit the event to the receiver detector will thus remain in the shutdown mode until three minutes after the first motion detected was transmitted The detector will transmit motion every three minutes High Traffic Shutdown Mode affects testing the motion detector in two ways When performing the module placement test the unit must be tampered by removing it from the backplate and replacing it The placement test be performed by creating motion in front of the device When performing a system test the unit must be left idle for three minutes before testing can be performed Once three minutes has passed motion in front of the detector to see if the device is both detecting motion and transmitting to the receiver Detector Transmission Delay motion detector transmission is always delayed by six seconds This is necessary to prevent false alarms caused by a motion sensor transmitting a delay zone has a chance to report This six second delay cannot be altered or disabled Test Mode motion detector has a walk test mode which will activate an LED for testing purposes During normal operation the LED will not turn on To put the in walk test mode create a tamper by removing the detector from its backplate and then replacing it Each time the detector senses motion it flash the red LED Six seconds after motion is detected the detector will send a signal to the receiver The detector will be in walk test mode until has sent 10 transmissions verify the pet immunity of the detector place the animal s within the coverage area and then move out of the zone Encourage the pet to move as it normally would and ensure that it moves across the detection pattern of the detector Verify that no alarm is initiated To test for catch per of humans create motion in the entire area where coverage is desired by walking perpendicular to the lens pattern Should the coverage be readjust or relocate the detector The Walk Test Mode will override the High Traffic Shutdown Mode If the installer is activating the walk test mode or replacing a battery then he must create 10 alarm transmissions before leaving the area It necessary because the indicator LED is still working and will not stop working until 10 alarm transmissions have been sent Installation Fig 3 This system is designed to work with the following consumer grade batteries Energizer Lithium EL123AP Panasonic Lithium CR123A or Lithium Ultra 123 Do not install any other type The reliability of the security system depends on its batteries and name or gene brand batteries may not provide the best quality and dependability Use of another type of battery may present a risk of fire or explosion Use a fresh battery Most batteries have a before date printed on their packaging or on the batteries themselves Buy batteries that have a before date of two years or more from your purchase date the motion detector from its mounting plate by holding the sensor by its sides and pushing up Remove the battery cover see Figure 3 the old battery and install new battery Place the battery cover back on NOTE Secure the battery cover with the small screw provided the sensor on its mounting plate making sure it snaps into place After the battery is installed the detector will take 60 seconds to warm up this time the LED will flash slowly The polarity of the battery must be observed Figure3 Improper handling of lithium batteries may result in heat generation explosion or which may lead to personal injuries DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE BY THE MANUFACTURER away from small children If batteries are swallowed promptly see a doctor Do not try to recharge these batteries Disposal of used batteries be made in accordance with the waste recovery and recycling regulations in your area The battery may explode if mistreated Do not dispose of in fire recharge or disassemble Operating Temperature 10 to 55 14 to 131 Operating Humidity 5 to 93 RH non cond Battery Life 9 years typical usage in room temperature Battery Nominal Voltage is 3V Low Battery Trouble indication is provided at 2.2V Compatible receivers RF5132 868 RFK55XX 868 SCW9045 9047 868 SCW9055 9057 868 PC9155 868 manuel d doit utilis en conjonction avec le manuel d du r sans fil DSC et du panneau de contr pour lequel ce dispositif con Le WS8904P d est con pour combiner la commodit d d sans fil avec la d efficace et fiable du mouvement humain et bonne protection contre la nuisance des fausses alarmes li des animaux domestiques pesant un maximum de 27

Related Files