Edwards 105XBRi Chameleon Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-105xbri-chameleon-instructions-2170365849.pdf |
---|---|
Type | |
Size | 1.28 MB |
Downloads |
Text Preview
Installation Instructions for Rebel ChameleonTM Series LED Multi Status Indicator in 4X Enclosures XTRA SAFE Technology is enabled and multiple col are energized the device will cycle through the energized at the following pre set flash rates 105XBRi Series Chameleon Multi Status LED Indicator a UL and cUL listed multi color LED signaling appliance when assembled in accordance with these installa instructions constitute a UL Listed Type 4X enclosure are UL Listed for Marine Use They are designed for in industrial applications or in applications where a Type enclosure is required When assembled in accordance these instructions the 105XBRi series visual signals UL Listed for use in Division 2 Hazardous Locations as in Table 1 lights are available in 24V DC and 120V 50 60 Hz They available in either Red Blue Amber or Red Green Amber Signaling NEW 105XBRi Multi status Indicator more chameleon like than ever With our new adaptive one device does it all With a quick change to the 105 Chameleon dip switch settings these flexible indicators instantly adapt for use with or without from an external PLC PAC or control relay Now of the application you will have just the right device the job with only half the inventory Enabled Chameleon 105XBRi devices ship as standard with Signaling XTRA SAFETM Technology patent Enabled XTRA SAFE multi status indicating employ patented combinations of color AND flash to provide more definite status indication to those who color blind With XTRA SAFE when Chameleon multi indicators are turned red they pulse at a rate of 240 per minute further emphasizing the urgency which color red typically connotes When amber these devices at a less urgent rate of 120 flashes per minute When multi status indicators are turned blue or green no other colors are energized the Chameleon devices steady on and do not flash Even in extreme cases no color is perceived flash rate variation provides a layer of visual indication 240 FPM 120 FPM or Blue 65 FPM Disabled in most cases the added layer of safety gained by op a multi status indicator with XTRA SAFE Technology desirable some applications may not require differentiation flash rates In other applications changes do not corre to escalating levels of urgency The adaptive design the new Chameleon 105 XBRi allows the product to be to accommodate these requirements by configuring dipswitches as shown in Figure 1 Applications WITH a separate PLC or Controller XTRA SAFE Technology With XTRA SAFE Disabled when red or amber unit pulses at a rate of 65 flashes per minute When multi status indicators are turned green or blue no other colors are energized the Chameleon devices steady on and do not flash XTRA SAFE Technology is disabled and multiple col are energized the device will cycle through the energized at 65 FPM Controlled Chameleon multi status indicators can also be used in where they will be controlled externally us a Programmable Logic Controller PLC or other such controller When externally controlled by a PLC of colors and flash rate are fully customizable can be programmatically determined In applications multiple colors are activated simultaneously the lights on a priority with red highest amber second and blue green the lowest Refer to Figure 1 Applications WITH separate PLC or Controller Wire color corresponds with indicated color wire Red LED wire Amber LED with Green tracer wire Green or Blue LED 1 Hazardous Location Ratings No Temperature B C D G B C D G 100C 212F 100C 212F 100C 212F 85C 185F 85C 185F 85C 185F Phone 800 336 4206 Fax 800 454 2363 3101612 ISSUE 3 2010 105BX junction box 105BM mounting and 105PM pipe mount attachments non conductive plastic fixtures and do not earth ground continuity when attached metallic wiring systems Therefore they intended for use with the 105XBRi series signals only when earth grounding is not 105BX junction box 105MB mounting and 105PM pipe mount attachments be used with metallic wiring systems only installed at the end of the run the mounting attachment as follows Cat No 105BX Secure the outlet box attachment to mounting surface using two screws not supplied for the surface Attach the adhesive backed to the top of the 105BX mounting box being to line up the holes in the gasket with the holes in the outlet box Cat No 105BM Using the four supplied screws the mounting bracket to Cat No 105BX box attachment as shown in Figure 1 Attach adhesive backed gasket to the top of the 105BM bracket being careful to line up the holes the gasket with the mounting holes in the outlet Refer to Figure 1 Cat No 105PM Install 3 4 19 mm conduit the pipe mount attachment onto the 3 4 19 conduit Attach the adhesive backed gasket to top of the 105PM pipe mount attachment being to line up the holes in the gasket with the holes in the outlet box as shown in Figure Mount 105XBRi Series as follows Unscrew the gasketed from the lens assembly as shown in Figures 1 and and remove the clear gasket from around the base Secure the base to the appropriate mounting attachment four screws supplied Replace the clear gasket the base with the flared open end facing down Specifications prevent electrical shock ensure that power turned off before installing the signal Number Green Amber Blue Amber 120V AC 50 60 Hz Specs DC 0.150 A AC 0.100 A DC 0.150 A AC 0.100 A must be in accordance with local codes The lens be positioned up for outdoor applications avoid risk of injury install lens before the unit and do not remove or light source when unit is energized EXPLOSION HAZARD not disconnect equipment unless power been removed or the area is known to be prevent electrical shock do not connect until instructed to do so Select a mounting configuration Figure 3 When Pull field wiring from conduit into the mounting Number 3101612 ISSUE 3 2 PLC Compatibility off state leak current DC on mA inrush duration A 65 AC 50 60 Hz mA A 212 mA mA Outlet Attachment Light Source Lens Countersunk screws mount lens to 105BM backed Mounting Screws to mount to 105BX backed Screws to mount to the surface Lens Base backed Pipe Mount 19 mm conduit 1 Mounting Cat No 105BM Mounting Bracket 2 Securing the Beacon to the Mounting Attachment Mount Attachment shown on a Cat No 105PM Pipe Attachment on a Cat No 105BX Outlet Box on a Cat No 105BM Mounting with the No 105BX Outlet Box 3 Mounting Configurations 3 Replacement Parts Lamp Lens Number LED Life L70 based on manufacturer projections Refer to 148,000 hour lamp is installed 148,000 hour lamp is installed 3101612 ISSUE 3 Wire the beacon as follows Figure 5 Set dipswitches for desired options Figure 4 Applications without a separate PLC or XTRA SAFE Technology Disabled dipswitch SW1 to the OFF position and SW2 the ON position For AC models There are four 24 wire leads white neutral red for activa