Edwards 108 Series Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-108-series-installation-instructions-5306274189.pdf
Type PDF
Size 652.41 KB
Downloads

Text Preview

Installation Instructions for 108 Series Chameleon Indicator Edwards Chameleon Multi Status Indicator is a UL and cUL multi color LED signaling appliance The enclosure is 3R 4X and IP65 rated lights are available in 24V DC and 120V 50 60 Hz They are in either red blue and amber or red green and amber pipe mount kit Cat No 102PMF sold separately and one of extension pipes sold separately allows the status indicator be raised above the mounting surface for increased visibility lights are designed such that any one or all three lights can be by either a PLC or contact closure The first light acti will illuminate either steady or flashing set by the internal If a second light is activated the Chameleon cycles the two colors A third activation causes the Chameleon cycle between all three colors red amber and green or red and blue Chameleon also features a multi tone base module that al the installer to select one of eight available tone options selected tone can be operated as a fourth signal or used in with any of the LED signals Chameleon is also available with two shorter bases that are when a lower profile is desired one for surface mounting and for pendant mounting The shorter bases do not allow for use a tone module additional light module can be used on the Chameleon For lens modules and light sources refer to Table 4 Compatibility electrical input characteristics for PLC compatible signals are in Table 2 Signals with these characteristics may be di connected to PLC output cards that do not exceed these characteristics must be in accordance with the latest edition of the Electrical Code and other governing standards and codes standard installation prevent electrical shock do not connect power instructed to do so using the 102PMF mounting kit perform the following All references below are to Figure 5 Using the supplied gasket D as a guide mark the four holes and the center clearance hole on an surface the four mounting holes Punch the wiring hole in the mounting surface to be sufficiently than that in the gasket to ensure the wiring is protected from abrasion by the gasket interfering with the mounting screw holes or other appropriate wire insulation abrasion as needed the pipe extension purchased separately into the flange Ground the flange by pulling the ground wire through mounting surface clearance hole and center hole of gasket Connect earth ground to the bottom of the mount flange using the ground screw G and wire terminal cup washer H Pull the remaining field wiring through center clearance of mounting surface center hole of the gasket pipe flange and extension pipe Align the mounting gasket D and flange A on the Secure using 4 10 24 x 1 25 mm pan head B 4 external tooth 10 star washers E and 10 24 hex nuts F Mount the base as instructed below not using the 102PMF mounting kit install base on 3 4 mm conduit not supplied Pull field wiring through entrance hole not using the 102PMF mounting kit mount using the method below For indoor applications the base may be panel or conduit mounted For NEMA3R 4X and applications it is recommended that either the or 108I series be used Cat Series 108I Install base on 3 4 19 mm conduit supplied Pull field wiring through conduit entrance Cat Series 108IP Install base on 3 4 19 mm conduit supplied Pull field wiring through conduit entrance Cat Series 108ID Using the supplied mounting gasket a template punch the four mounting holes Punch the clearance hole in the mounting surface to be larger than that in the gasket to ensure the insulation is protected from abrasion by the gasket interfering with the mounting screw holes or other appropriate wire insulation abrasion as needed Mount the base to the surface using 2 screws supplied Cat Series 108I Connect field wiring to the terminal as shown in Figure 1 additional field wiring to the terminal block on the signal assembly as shown in Figure 2 The tone module may be wired to sound independently in conjunction with an LED signal sound tone module independently connect to separate lead prevent abrasion of wiring insulation ensure wire passage holes are adequately protected Connect field wiring CT 203 699 3000 FAX 203 699 3365 CUST SERV 203 699 3078 TECH SERV 3100178 ISSUE 3 2000 sound tone module with a particular light source horn hot terminal to selected light terminal on terminal block Cat Series 108IP or Cat Series 108ID Using wire nuts 18 457 mm wire leads to field wiring The leads are marked as follows Neutral Red Blue for with Red Amber and Blue LEDs or Green for with Red Amber and Green LEDs Amber and Module using a second module install as follows see Figure 4 Loosen the captive screw in the cap and remove the cap the unit the captive key in the second lens module into the position the second lens module on top of the first Push in the captive key to secure the lens module the light source into board grooves at bottom of module ensuring that the four prongs on the PC are aligned with the plug located in the back of the assembly prevent leakage ensure the magnifier ring on the cover and the magnifier ring on the lens module aligned Figure 4 When using LED light sources ensure that the color of LED light source and the lens assembly match the lens assembly cover on the front of the lens and secure using two captive screws Replace the cap on top and secure the cap with the captive using the Cat No 108I set the selected tone See Table 3 Figure 3 Apply power to the unit and verify proper operation lens surfaces should be periodically dusted and cleaned with dry soft clean cloth to maintain optimum light visibility If the outside of the lens may be cleaned with water and a detergent on a well rung out soft clean cloth 1 Specifications Mount Mount Mount Mount Mount Short Base Mount Short Base Mount Short Base Mount Short Base Mount Mount Mount Mount 50 60 Hz 50 60 Hz DC DC 50 60 Hz 50 60 Hz DC DC 50 60 Hz 50 60 Hz DC DC A A A A A A A A A A A A Inrush 2 2 1 ms 1 ms 2 2 1 ms 1 ms 2 2 1 ms 1 ms Current 4 ms 60 Hz 4 ms 60 Hz 2 ms 120 Hz 2 ms 120 Hz green amber blue amber 2 ms 500 1 kHz red green amber blue amber 2 ms 500 1 kHz green amber blue amber green amber blue amber green amber blue amber green amber blue amber 4 ms 60 Hz 4 ms 60 Hz mA mA mA mA current rating for the 108I series indicates an activated tone in the multi tone module 1 Wiring 3100178 ISSUE 3 N E U TR AL N T ER M INA L LO C K EPA R ATE H O T LE A D O R O N N EC T ED TO AP P R O P R IATE H T M O DU LE TE R M IN A L R M IN A L B LO C K 2 Wiring the Tone Module 2 PLC Compatibility cid 22 cid 14 cid 16 cid 16 cid 10 cid 12 cid 9

Related Files