Installation Instructions for 125 Class Beacons XTRA BRIGHT LED Models 125 Class XBR LED Beacons are UL and cUL listed mode signaling appliances rated for NEMA 4X applica Two versions of 125 Class XBR LED Beacons are Steady On Flashing 125XBRM and Steady On 125XBRZ Both versions can be either surface or mounted A protective wire guard Cat No 125GRD also available 125XBRM and 125XBRZ beacons are dual mode devic maximizing application flexibility while reducing inventory 125XBRM beacons ship from the factory in Steady On with the built in option of switching to 65 fpm Flashing by means of an additional wire connection Refer to the Flash Mode for details In the same manner beacons ship from the factory in Steady On mode where ultra visibility is critical can be easily switched Lightburst mode Refer to Setting the Flash Mode for 125 Class XBR XTRA BRIGHT LED Beacons are in red blue green amber or white Specifications BASE Number BASE Number 120V AC 50 60 Hz Specs DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A DC 0.215A AC 0.108A Specifications Locations Ratings 31F to 150F 35C to 66C prevent electrical shock ensure that power turned off before installing the signal Mounting Figures 1 3 Feed the 18 457 mm signal wire leads through either or 3 4 conduit into an approved conduit outlet box is supplied with a double threaded 1 2 internal 3 4 external conduit hub Thread the conduit onto the base of the signal Mounting Figures 2 4 When panel mounting these beacons the surface construction details of the panel must be into consideration in order to ensure that the of the outdoor NEMA 4X rating is fully Installer should evaluate Place the mounting gasket supplied over the hole in panel and route the signal wires through the gasket the hole in the panel the base through the hole in the panel and screw locking nut supplied with the raised locking edge the mounting surface onto the base to secure the avoid risk of injury install lens before the unit and do not remove or light source when unit is energized Using wire nuts not supplied connect the signal leads as shown in Figure 1 or 2 Polarity must be on DC models AC Models Connect the black wire to hot and the wire to common DC Models Connect the red wire to positive and black wire to negative Phone 800 336 4206 Fax 800 454 2363 3101568 ISSUE 3 2010 Turn on power and verify that the signal operates the Flash Mode change the flash mode from Steady On to Flashing on beacons or from Steady On to Lightburst on beacons connect the optional yellow wire as AC Models Connect yellow wire to hot DC Models Connect yellow wire to positive When using as shipped in Steady On mode cap yellow wire with a wire nut supplied Figures 1 4 for details avoid risk of injury install lens before the unit avoid the risk of injury do not start any when unit is energized power before cleaning The module lens exterior should be periodically cleaned with a soft clean using water and a mild detergent to maintain optimum visibility 1 Conduit Mounting 3 4 Shown 2 Panel Mounting Nut OD panel connected nut supplied Series Visual Indicator NPT external shown NPT internal not supplied Wire Leads units Red positive units Black Hot units Black negative units White Neutral Nuts supplied Source Series Visual Indicator Wire Leads units Red Positive units Black Hot units Black negative units White neutral Nuts Supplied Source Wiring for 125XBRM or 125XBRZ Steady On Mode Wiring for 125XBRM or 125XBRZ Steady On Mode connected nut supplied 3101568 ISSUE 3 3 Conduit Mounting 3 4 Shown 4 Panel Mounting Nut OD panel wire connected optional flash pattern units Connect Positive units Connect to Hot Series Visual Indicator NPT external shown NPT internal not supplied Wire Leads units Red positive units Black Hot units Black negative units White neutral nuts not supplied leads to Source wire connected for Optional flash pattern units Connect to Positive units Connect to Hot Series Visual Indicator Signal Wire units Red Positive units Black Hot units Black negative units White neutral Nuts Supplied Source Wiring for 125XBRM Flashing Mode Wiring for 125XBRZ Lightburst Mode Wiring for 125XBRM Flashing Mode Wiring for 125XBRZ Lightburst Mode 1 Replacement Parts BASE BASE Number Lamp Number fpm Flashing LED LED in this position indicates lens LED color A amber B blue G green R red white LED with clear lens color A amber B blue C clear G green R red LED Life L70 based on LED manufacturer projections Refer to 148,000 hour LED light is permanently installed 148,000 hour LED light is permanently installed 3101568 ISSUE 3 800 336 4206 800 454 2363 519 376 2430 519 376 7258 852 2907 8108 852 2142 5063 61 3 9239 1200 61 3 9239 1299 32 2 725 11 20 32 2 721 86 13 America 305 593 4301 305 593 4300

Related Files