Edwards 2400 series panel manual

File Preview
File Preview
Click below to download for free

File Data

Name edwards-2400-series-panel-manual-3827694510.pdf
Type PDF
Size 3.16 MB
Downloads

Text Preview

Installation Instructions Operation Manual Two to Eight Zone Series Alarm Control Panels 46000 1320 Rev 1.6 Edwards product has been designed to meet the requirements of NFPA Standard 72 1990 Edition Laboratory Inc Standard 864 May 2 1991 Edition and Underwriters Laboratory Canada Inc Standard ULC S527 Installation in accordance with this manual applicable and the instructions of the Authority Having Jurisdiction is mandatory WARNING This equipment can generate and radiate radio frequency energy If this is not installed in accordance with this manual it may cause interference to radio This equipment has been tested and found to comply within the limits for A computing devices pursuant to Subpart J of part 15 of the FCC Rules These rules are to provide reasonable protection against such interference when this equipment is in a commercial environment Operation of this equipment in a residential environment likely to cause interference in which case the user at his own expense will be required to whatever measures may be required to correct the interference and thoroughly understand this manual before proceeding to install and operate the panel ensure proper operation of the control of the panel only those initiating signaling and devices whose compatibility with the panel has been established by Underwriters may be connected to the control panel Refer to the compatability information supplied with the panel for a complete list of compatible devices all installation wiring for opens shorts or grounds and correct any fault found before wiring to the control panel not connect AC or battery power until indicated of the control panel must be performed by qualified fire alarm service only Information The dialer complies with Part 68 of the FCC rules The Dialer FCC registration number and the Ringer Number REN are on the back of the dialer This information must be provided to the telephone if requested An FCC compliant telephone cord and modular plug cord is supplied with the dialer The dialer is designed to be to the telephone network using the supplied cord and an RJ31X or RJ38X jack which must also with FCC Part 68 rules The REN is used to determine the quantity of devices which may be connected to the telephone line Excessive on the telephone line may result in the devices not ringing in response to an incoming call In most but all areas the sum of RENs should not exceed five 5 To be certain the number of devices that may be to a line as determined by the total RENs contact the local telephone company the dialer causes harm to the telephone network the telephone company will notify you in advance that discontinuance of service may be required If advance notice isn practical the telephone company notify you as soon as possible You will also be advised of your right to file a complaint with the FCC if you it is necessary The telephone company may make changes in it facilities equipment operations or procedures that could the operation of the dialer If this happens the telephone company will provide advance notice in order for to make necessary modifications to maintain uninterrupted service trouble is experienced with the dialer for repair or warranty information contact Edwards Co 90 Fieldstone Cheshire Ct 06410 1212 Telephone 1 203 699 3000 If the dialer is causing harm to the telephone the telephone company may request you disconnect the dialer until the problem is resolved No repairs may be performed on the dialer by the user The dialer cannot be used on public coin phone or party line service provided by the telephone company DOC Information The Canadian Department of Communications label identifies certified equipment This means that the equipment meets certain telecommunications network protective operational safety requirements The Department does not guarantee the equipment will operate to the user installing this equipment users should ensure that is permissible to be connected to the facilities of local telecommunications company The equipment must also be installed using an acceptable of connection The customer should be aware that compliance with the above conditions may not degradation of service in some situations to certified equipment should be made by an authorized Canadian maintenance facility by the supplier Any repairs or alterations made by the user to this equipment or equipment may give the telecommunications company cause to request the user disconnect the should ensure for their own protection that the electrical ground connections of the power utility lines and internal metallic water pipe system if present are connected together This may be particularly important in rural areas Users should not attempt to make such connections themselves but should contact the electric inspection authority or electrician as appropriate The Load Number LN assigned to each terminal device denotes the percentage of the total to be connected to a telephone loop which is used by the device to prevent overloading The on a loop may consist of any combination of devices subject only to the requirements that the of the Load Numbers of all the devices does not exceed 100 TECHNICAL ASSISTANCE PLEASE CALL YOUR LOCAL REPRESENTATIVE ON THE FOLLOWING PAGE Page for P N 46000 1320 Edwards 2400 Manual Release Corrections 2400 ADM 2400 ADS 2400 RTU Module Information Table 2.1 to Table 1.1 Add Table 1.2 Correct Cat 2245 2445 part numbers Delete Table 5.9 Add Table 10.11 Battery Box revise battery tables Revise 4 wire EOL Relay Auxiliary Power note Revise RCT delete remote station from module Add 2400 DL1 Dialer Module Revise 2400 ADMM operation add additional replacement parts dialer and compatibility information corrections Revised Dialer Information Added warning of Contents DESCRIPTION 1 4 Components 2 APPLICATION 5 Alarm System Limitations 5 THEORY OF OPERATION 5 8 Device Circuits IDCs 5 Appliance Circuits IACs 8 INSTALLATION 9 15 Codes and Standards 9 Site Storage 9 Drawing References 9 Instructions 10 PROGRAMMING 16 20 Programming Initiating Device Circuits IDCs 17 Programming Indicating Appliance Circuits IACs 18 Configuring System Timers 19 Programming Auxiliary Power 19 Returning to Panel Default Settings 20 Dialer Module 20 OPERATION 22 26 Mode 22 Mode 22 Mode 23 Mode 23 Mode 24 Mode

Related Files