Edwards 3101961-EN R003 57PLEDM Series Rotating Polaris LED Beacon Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Series Rotating LED Beacon Sheet 57PLEDM Series Rotating Polaris LED Beacon is UL and cUL for general signaling use The beacon is available in VAC or multivoltage 12 VDC 24 VAC or 24 VDC models There six lens colors to choose from and a choice of black or gray bases beacon utilizes high power LED lights and is suitable for indoor or use The beacon is provided with an enclosure rated for NEMA 4X and IP66 beacon is well suited for high ambient noise level areas especially ear protection must be worn It is also ideal for high vibration and areas where LED technology provides longer lamp The beacon features a 360 degree beam of light with 16 user flash or rotation patterns including Steady The patterns are by pressing the Edwards logo push button The factory setting Light Burst pattern beacon is designed to be mounted on 3 4 in NPT conduit indoor outdoor To maintain the NEMA Type 4X and IP66 ratings for installation the beacon must be mounted with the dome facing up When installing the beacon indoors in dry environments it be mounted in any position the beacon in accordance with the applicable requirements in latest edition of the National Electrical Code Canadian Electrical and local codes prevent electrical shock ensure that the power is before installing the beacon prevent leakage and potential electrical shock use care when the beacon to prevent tearing of the permanently gaskets provided for the environmental integrity and When mounting outdoors the beacon must be installed with the or dome facing directly up The beacon is designed to be conduit mounted install the beacon Remove the three screws from the bottom of the beacon base 1 Separate the beacon baseplate to gain access to the wiring The beacon mounts on a 3 4 in NPT conduit pipe The threaded entry is located on the bottom of the base the baseplate on the conduit Wrench tighten for a leak free Route the field wiring from the appropriate power source through conduit and then through the conduit entrance in the Wire in accordance with below Place the connected wires inside the base and secure the beacon plate to the base using the screws provided Figure 1 Apply power and verify proper operation the beacon in accordance with the applicable requirements in the edition of the National Electrical Code Canadian Electrical Code local codes wire the beacon for 120 VAC Using wire nuts not supplied connect the field wiring to the wiring Connect the beacon black lead to hot the white lead to neutral the green lead to ground wire the beacon for 12 VDC Using wire nuts not supplied connect the field wiring to the Connect the beacon red lead to positive and the black lead to wire the beacon for 24 VAC VDC Using wire nuts not supplied connect the field wiring to the Connections depend on the voltage supply Choose the that match your power supply VAC Connect the beacon black lead to hot the red lead to and the green lead to ground VDC Connect the beacon red lead to positive and the lead to negative the flash or rotation pattern beacon can be configured with one of 16 user selectable flash or patterns using a push button membrane switch The push is located in the center of the Edwards shield logo on the base the beacon Figure 1 select a flash or rotation pattern Press and hold the push button for one second to switch to the pattern in the sequence Table 1 Press and hold the push button for three seconds to set the back to the first pattern Steady wiring wiring 2017 United Technologies Corporation 3 3101961 EN REV 003 ISS 26OCT17 1 Installation Dome Dome screw 4X Lens LED tower O ring Beacon base Push button Base screw 3X Baseplate 1 Flash and rotation patterns Steady S65 Light Burst Singular Burst Binary Burst Quad Burst iBurst Rotating 80 RPM Rotating 95 RPM Rotating 130 RPM Rotating 200 RPM Slow Rotating with Burst Flash Rotating with Burst Quad Flash with Pop Variable Rotating Variable Flashing Flashes Per Minute Rotations Per Minute and dome replacement steady Single FPM FPM seven pulses ms off Single FPM Double FPM Quad FPM pulses at 750 FPM Off pulses at 750 FPM Off pulses at 870 FPM Off RPM RPM RPM RPM rotations at 84 RPM pulses at 940 FPM rotations at 174 RPM pulses at 900 FPM pulses at 650 FPM 160ms Off pulse at 410 FPM 410 ms Off to 420 RPM repeated every 6.6s 535 Single FPM repeated 4.1s Electrocution hazard To prevent electrical shock the beacon from the supply circuit and allow five minutes stored energy to dissipate before disassembling Do not overtighten the screws or damage to the dome may replace the lens or the dome Remove the four screws from the dome and lens assembly and remove the dome and lens as shown in Figure 1 Make sure the O ring is in place around the base of the unit and replace the lens and dome Reinstall the four screws and tighten each firmly until the gasket compresses between the dome and the screw head To prevent damage to the lens or dome do not use abrasive or cleaners clean the lens surface with a soft cloth and water or a mild solution to maintain optimum light visibility Ensure that the is completely dry before assembling the beacon 3 3101961 EN REV 003 ISS 26OCT17 2 Specifications number base base 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm specs VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VAC 0.250 A VAC 0.250 A VAC 0.250 A VAC 0.250 A VAC 0.250 A VAC 0.250 A 2 Dimensions in mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 6.5 in 203 165 mm 4 Replacement parts outer dome The letter in this position indicates the color of the lens A amber blue C Clear G green M magenta or R red For example part number for a red lens would be 57E LR 57PLEDMW uses a clear lens number information American standards 1638A cUL C22.2 No 205 information contact information see www edwardsfiresafety com in mm 3 Electrical specifications voltage VDC VAC VDC state leakage current 5 mA On current mA 12 VDC mA VAC VDC A 2 ms VAC mA mA inrush duration The letter in this position indicates the color of the lens A amber blue C clear G green M magenta or R red A 1 ms 3101961 EN REV 003 ISS 26OCT17 3

Related Files