Series Rotating LED Beacon Sheet 94PLEDM Series Rotating Polaris LED Beacon is UL and cUL for general signaling use The beacon is available in VAC or multivoltage 12 VDC 24 VAC or 24 VDC models There six lens colors to choose from and a choice of black or gray bases beacon utilizes high power LED lights and is suitable for indoor or use The beacon is provided with an enclosure rated for NEMA 4X and IP66 beacon is well suited for high ambient noise level areas especially ear protection must be worn The beacon is also ideal for high applications and areas where long lamp life is advantageous beacon features a 360 degree beam of light with 16 user flash or rotation patterns including Steady The patterns are by pressing the Edwards logo push button The factory setting Light Burst beacon is designed to be mounted on 3 4 in NPT conduit indoor outdoor To maintain the NEMA Type 4X and IP66 ratings for installation the beacon must be mounted with the dome facing up When installing the beacon indoors in dry environments it be mounted in any position the beacon in accordance with the applicable requirements in latest edition of the National Electrical Code Canadian Electrical and local codes hazard To prevent electrical shock ensure that is disconnected before installing the beacon hazard To prevent leakage and potential electrical use care when disassembling the beacon to prevent of the permanently affixed gaskets provided for the integrity and ratings hazard To prevent leakage and potential electrical when mounting outdoors install the beacon with the lens or facing directly up The beacon is designed to be conduit mounted install the beacon Release the latch on the clamp ring and remove the ring holding protective dome to the signal base Lift the dome straight up off the beacon base Figure 1 Loosen the three screws in the keyhole slots in the base of the turn the lens clockwise and lift it off of the LED light source plate Remove the three screws holding the LED light source support to the beacon base Gently grasp the LED tower and carefully lift the support plate off the beacon base The beacon mounts on a 3 4 in NPT conduit pipe The threaded entry is located on the bottom of the base Route the field wiring from the appropriate power source through conduit and then through the conduit entrance hole in the base the base on the conduit Wrench tighten for a leak free seal Wire in accordance with below Place the connected wires inside the base and reassemble the Figure 1 Apply power and verify that the beacon operates properly this unit in accordance with all applicable local codes and and the local authority having jurisdiction wire the beacon for 120 VAC Using wire nuts not supplied connect the field wiring to the wiring Connect the beacon black lead to hot and the white lead to Connect the beacon green lead to the grounding point in the signal base wire the beacon for 12 VDC Using wire nuts not supplied connect the field wiring to the wiring Connect the beacon red lead to positive and the black lead to wire the beacon for 24 VAC VDC Connect the field wiring to the beacon wiring using wire nuts not Connections depend on the voltage supply Choose the that match your power supply VAC Connect the black lead to hot and the red lead to neutral VDC Connect the red lead to positive and the black lead to Connect the green lead to the grounding point in the beacon base the flash or rotation pattern beacon can be configured with one of 16 user selectable flash or patterns using a push button membrane switch The push is located in the center of the Edwards shield logo on the base the beacon Figure 1 2017 United Technologies Corporation 3 3101962 EN REV 003 ISS 26OCT17 To prevent damage to the lens or dome do not use abrasive or cleaners clean the lens surface with a soft cloth or sponge and or a mild detergent solution to maintain optimum light visibility sure the lens is completely dry before assembling the beacon 1 Installation Dome Lens Screw 3X LED tower Screw 3X LED light source support plate Beacon base Clamp ring Push button 1 Flash and rotation patterns Steady S65 Light Burst Singular Burst Binary Burst Quad Burst iBurst Rotating 80 RPM Rotating 95 RPM Rotating 130 RPM Rotating 200 RPM Slow Rotating with Burst Flash Rotating with Burst Quad Flash with Pop Variable Rotating Variable Flashing steady Single FPM FPM seven pulses ms off Single FPM Double FPM Quad FPM pulses at 750 FPM Off pulses at 750 FPM Off pulses at 870 FPM Off RPM RPM RPM RPM rotations at 84 RPM pulses at 940 FPM rotations at 174 RPM pulses at 900 FPM pulses at 650 FPM 160ms Off pulse at 410 FPM 410 ms Off to 420 RPM repeated every 6.6s 535 Single FPM repeated 4.1s Flashes Per Minute Rotations Per Minute select a flash or rotation pattern Press and hold the push button for one second to switch the to the next pattern Table 1 Press and hold the push button for three seconds to set the to the first pattern Steady and dome replacement Electrocution hazard To prevent electrical shock the beacon from the supply circuit and allow five minutes stored energy to dissipate before disassembling Do not overtighten the screws or damage to the dome may replace the lens or dome Release the latch on the clamp ring and remove the ring holding protective dome to the signal base Lift the dome straight up off the signal base Loosen the three screws in the keyhole slots in the base of the Turn the lens clockwise and lift it straight up off of the support Replace the lens by turning it counter clockwise in the keyhole and then tightening the three screws Replace the dome and reinstall the clamp ring 3 3101962 EN REV 003 ISS 26OCT17 2 Specifications number base base 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm White specs VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VDC 0.700 A VAC VDC 0.550 A VAC 0.250 A VAC 0.250 A VAC 0.250 A VAC 0.250 A VAC 0.250 A VAC 0.250 A 2 Dimensions 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm 7.75 in 210 200 mm White 4 Replacement parts outer dome The letter in this position signifies the color of the lens A amber blue C clear G green M magenta or R red For example part number for a red lens would be 93 LR 94PLEDMW uses a clear lens number information American 1638A cUL C22.2 No 205 information contact information see www edwardsfiresafety com VAC 3 Electrical specifications voltage VDC VAC VDC mA state leakage On current 700