Edwards 5522M-AQ 5523M-AQ and 5522M-Y6 5523M-Y6 Installation Instruction
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-5522m-aq-5523m-aq-and-5522m-y6-5523m-y6-installation-instruction-2701463859.pdf |
---|---|
Type | |
Size | 742.46 KB |
Downloads |
Text Preview
and 5523M Duotronic Installation Sheet 5522M and 5523M Duotronic Signals are high decibel signaling intended for indoor use where distinctive audible signals required in hazardous locations The 5522M series are horns and 5523M series are sirens The units are rated at an average 110 dB 5522M and 5523M series are UL and cUL listed for use in the locations shown in Table 2 flange bolts of all series of the signals are sealed in accordance UL requirements to prevent disassembly and tampering equipment is suitable for use in Class I Division 1 Groups B C D Class I Division 2 Groups A B C and D hazardous locations General Signaling Service and wire this device in accordance with applicable national and codes ordinances and regulations and in a manner acceptable the local authority having jurisdiction the device is used in general signaling applications you must it in accordance with these instructions and with the applicable of NFPA 70 in the US or CSA C22.1 in Canada the device is used in Division 2 applications you must install it in with the NFPA 70 Article 501 4b Explosion hazard Do not disconnect equipment unless power has removed or the area is known to be nonhazardous Explosion hazard Substitution of any components may impair for Class I Division 2 Explosion hazard Do not disconnect equipment while the circuit is or unless the area is known to be free of ignitable To prevent fire shock and component damage no work including board removal should be performed while the circuit is install the signal Choose the mounting location The horn or siren can be mounted any solid surface Ensure that the mounting location provides clearance to enable adjustment of the signal to the position after mounting The signal position can be within an approximate 180 degree range vertically or depending on the mounting of bracket Mount the unit in the selected location using its mounting bracket three bolts not supplied See Figure 1 for the unit size and location of mounting holes Adjust the signal direction as desired by loosening the two bolts in Figure 1 Rotate the signal to the desired position and tighten the bolts Wire the unit as shown in Figure 2 Remove cover from the conduit outlet box not supplied Note the outlet box must be suitable for use in the hazardous Feed the two power supply wires through the 1 2 in NPT not supplied into the outlet box Feed the signal s two power connection wires either directly the outlet box or if desired through a 1 2 in flexible type not supplied and then into box Do not apply power to the unit until installation is and the housing cover and outlet box cover are Secure the outlet box to the signal s 1 2 14 NPT sealed either directly or by flexible coupling and then secure conduit to outlet box Connect the power supply wires using two wire nuts not Polarity need not be observed when making for a DC voltage source Replace the cover securely on the conduit outlet box Apply power to the signal and verify that it sounds correctly 1 Signal dimensions and mounting details in 127 mm in 63 mm in mm in mm in mm 1 2 in 13 mm mounting holes 3X Bolts for adjusting signal direction 2X 2015 UTC Fire Security All rights reserved 2 3100796 EN REV 04 ISS 16JAN15 information 12.12.01 C22.2 No 30 C22.2 No 205 464 1203 1480 information contact information see www edwardssignaling com 2 Wiring installation and connections Power supply wires from selected AC or DC voltage source for 2X 1 2 in NPT conduit not supplied attached to outlet box Outlet box suitable to hazardous location Green wire for earth ground 1 2 14 NPT nipple not supplied Adaptatone signal Power connection wires from signal 2X Wire nuts not supplied To earth ground and testing the unit semi annually for external accumulation of dirt Clean necessary the signal monthly or at the intervals required by applicable and codes to Table 1 to Table 1 lb 8.4 kg locations 1 locations Hazardous locations and variable ambient conditions apply only UL Listings are accepted to 104 to 40 to 151 to 66 ambient temp temp 1 Input power VDC VAC 50 60 Hz VDC VDC VAC 50 60 Hz VAC 50 60 Hz A 2 Hazardous locations number location I Div 1 Groups B C D I Div 2 Groups A B D code 100 212 2 3100796 EN REV 04 ISS 16JAN15