Edwards 5533MD Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-5533md-installation-instructions-9781640532.pdf
Type PDF
Size 791.20 KB
Downloads

Text Preview

Installation Instructions for Hazardous Location Use Adaptatone Catalog Number 5533MD AW should be completed in accordance with either the Electrical Code or the Canadian Electrical Code appli local codes and the latest edition of either NFPA72 National Alarm Code or CAN ULC S524 Standard for the Installation of Alarm Systems Mount Adaptatone to any solid surface using its mounting and 3 bolts not supplied Figure 1 mating surfaces of housing clean and to maintain the integrity of the Location construction Open Adaptatone by removing the 8 nuts and bolts and off housing cover Keep mating surfaces of housing for proper reassembly installation take care not to damage on the printed circuit board miniature programming switch on the printed circuit board 2 for the desired tone s Refer to tone program chart inside cover and Table 1 one tone and set SW1 Figure 2 Check Adaptatone label for proper operation voltage Install source and initiating circuit wires through a 1 2 13 conduit attached to an outlet box and nipple The outlet conduit and nipple must be suitable for the Hazardous application with 1 2 13 mm 14 NPT threading at openings Outlet box conduit and nipple are not cover from outlet box Feed five numbered wires a 1 2 13 mm 14 NPT nipple not supplied into the box Secure outlet box to Adaptatone not apply power to the unit until installation is and housing cover and outlet box cover secured green ground wire to earth ground to a supervised signaling circuit as shown in Figure 4 must be observed and Operation Hazardous Location Use Adaptatone signals catalog 5533MD AW are tone selectable diode polarized au signaling appliances primarily intended for use in fire alarm and other applications requiring electrical supervision of circuit field wiring The signals can be field programmed sound any of 56 tones Descriptions of the tones are provided Table 1 Directions for tone programming and information re suitability of the tones for fire alarm use are provided on inside of the signal housing cover 5533MD AW models are UL and ULC listed for safe use in I Groups B C and D atmospheres Specifications 18.4 Pounds 8.4 kg Ambient Temp 32F to 104F 0C to 40C Specifications POWER DC Current A On 1 Dimensions 3100793 REV 02 REB 21FEB13 outlet box cover sound level is factory set to maximum Adjust volume if desired by turning potentiometer R72 Figure 2 Adjust speaker direction by loosening 2 nuts and pivoting to desired position Figure 3 Tighten 2 nuts mating surfaces are clean and undamaged Secure cover aligning the straight edge of the cover with the edge of the housing Torque nuts evenly in opposing to 140 to 150 in lb Apply power Verify operability and Test not apply power to the unit until installation is and housing cover and outlet box cover are the unit semi annually for external accumulation of dirt if necessary Adaptatone should be tested annually or as required by the authority having jurisdiction to ensure continuous service mm mm MOUNTING PIVOTS 180 A DETAIL A NUTS TO TURN ADJUST LEVEL NUTS BOLTS COVER FOR CLARITY ONLY SELECTED COMPONENTS ARE SHOWN 2 Adaptatone PC Board and Mounting Holes Model Shown NUTS LOOSEN TO ADJUST DIRECTION 3 Speaker Adjustment and Operation No 5533MD AW mode shown below On a notification appliance circuit signal sounds when polarity of signal voltage reverses from that of mode not apply power until installation is and housing covers are secure instructions furnished with fire systems and those on this figure ensure correct installation outlet box conduit and nipple must be suitable for hazardous location applications 4 Wiring of 5533MD AW Adaptatone to Supervised Signaling Circuits POSITIONS 6 5 4 3 2 1 DESCRIPTION HEX 15 Tone Programming Tone Dong Whoop 1 Whoop Siren Horn Tone 2 Blind Mice Tone Alert Whoop Pulse Horn Pulse Air Horn Pulse Dual Tone Pulse Chime 2 Police Fire Slow Whoop General Toxic Police 2 Stutter Sweep 2 Horn Cont Horn Temp 1 2 2 Beep Freq Steady Alert Freq Fast Siren Freq Slow Siren PFEER 32 001 to Joy Little Star Banjos Cucaracha Rose of Texas Pulse Tones are for Evacuation Use Only On Switch Off Switch 5 4 3 2 1 pairs of 700 and 570 Hz tones each damped to zero and 770 Hz alternately 87 ms each Hz up and down sweep in 8 seconds and repeat 470 Hz 83 ms on 109 ms off Hz upward sweep in 4 seconds and repeat Hz 0.55 seconds on 0.55 seconds off Hz percussive repeat at 1 Hz Hz upward sweep in 1 second and repeat to 600 Hz alternately 0.52 seconds each Hz up and down sweep in 0.25 seconds and repeat 600 Hz downward sweep in 1.6 seconds and repeat Hz continuous Hz continuous 500 Hz 0.4 to 0.5 second cycle Hz percussive repeat at 1 Hz measures 411 Hz 520 Hz 407 Hz 312 Hz measures 787 Hz 714 Hz 625 Hz 952 Hz 333 Hz 625 Hz up and down sweep in 13 ms and repeat and 770 Hz alternately 50 ms each for 1.2s 1.5 s delay and repeat 2000 Hz up and down steps 750 ms delay and repeat 641 and 896 Hz 200 ms each 1 second delay and repeat 422 775 Hz upward sweeps 850 ms each 1s delay and repeat Hz 3 0.5s pulses separated by 0.5s followed by 1.5s delay and repeat Hz 3 0.5s pulses separated by 0.5s followed by 1.5s delay and repeat 500 Hz 0.4 to 0.5s cycle 3 0.5s pulses separated by 0.5s followed by delay and repeat Hz 3 0.5s pulses separated by 0.5s followed by 1.5s delay and repeat Hz and 800 Hz alternately 0.250 seconds each Hz and 864 Hz downward sweep in 0.134 seconds Hz to 1312 Hz upward sweep in 3s followed by 0.5s delay and repeat Hz for 0.5 seconds followed by 0.5 second delay and repeat Hz continuous Hz and 440 Hz alternately 0.800 seconds each Hz for 0.146 seconds followed by 0.102 seconds delay and repeat Hz to 413 Hz downward sweep in 1.17 seconds and repeat tones at 567 Hz and 326 Hz for 0.052 seconds each Hz to 746 Hz alternating for 0.003 seconds each Genesis horn Genesis horn Hz and 493 Hz alternately 0.002 seconds each Hz and 493 Hz alternately 0.005 seconds each of 2336 Hz and 493 Hz each alternating for 0.005s followed by 1s delay Hz for 0.040s 235 Hz for 0.020s 235 Hz for 0.160s 260 Hz for 0.050s Hz for 0.1009s 235 Hz for 0.050s 357 352 382 355 375 384 375 and 364 Hz alternately on for 0.050s 4545 3704 2777 4347 3704 2500 Hz alternately on for 0.003s Hz continuous to 3048 Hz up and down sweep in 0.130 seconds to 3048 Hz up and down sweep in 0.500 seconds downward from 1336 Hz to 522 Hz in 1.2 seconds and repeat Hz for 0.100 seconds and 461 Hz for 0.400 seconds seconds of melody followed by 1 second delay and repeat seconds of melody followed by 1 second delay and repeat seconds of melody followed by 1 second delay and repeat seconds of melody followed by 1 second delay and repeat seconds of melody followed by 1 second delay and repeat use of evacuation signals on this product that is specifically Listed for

Related Files