Edwards 5541M Series Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-5541m-series-installation-instructions-0745891326.pdf
Type PDF
Size 1.52 MB
Downloads

Text Preview

Cheshire CT 06410 203 699 3300 Ph Cust Serv Fax Tech Serv Fax and Operation of the Number 5541M Y6 System Master System Master SIGNALING MODE INPUT 3100471 ISSUE 3 2003 BY EDWARDS SIGNALING NOTICE 2003 IMFORMATION of liability product has been designed to meet the requirements of Underwriters Inc Standard 2017 and 864 Installation in accordance with manual applicable codes and the instructions of the Authority Having is mandatory The manufacturer shall not under any be liable for any incidental or consequential damages from loss of property or other damages or losses owing to the of products beyond the cost of repair or replacement of any products The manufacturer reserves the right to make product and change product specifications at any time every precaution has been taken during the preparation of this to ensure the accuracy of its contents the manufacturer assumes responsibility for errors or omissions Warning equipment has been tested and found to comply with the limits for a A digital device pursuant to part 15 of the FCC Rules These limits designed to provide reasonable protection against harmful when the equipment is operated in a commercial This equipment generates uses and can radiate radio energy and if not installed and used in accordance with the manual may cause harmful interference to radio Operation of this equipment in a residential area is likely cause harmful intereference in which case the user will be required to the interference at his own expense Statement System Master when properly installed operates with a Local Premises Fire Alarm System in accordance with the following Laboratories Standard 864 System Master when properly installed can also be to operate as a self monitored evacuation device in with the following standard Laboratories Standard 2017 1 overview and operation overview 1 Review 1 and Indicators 1 the Panel 5 2 3 checklist 7 the cabinet 7 Power 7 a Satellite Panel 10 Speaker Amplifiers 11 External Initiating Inputs 11 to Output Relay 12 External Initiating Input to Fire Panel 12 to a UL Listed Telephone Access 13 to Remote Paging Units 14 Audio Levels 15 16 Alarm Input Assignment 16 Output Assignment 16 Commission 16 Zone ControlTM 17 Setup 17 Address Assignment 17 Mode 17 Learn Mode 17 to Input Assignment 18 Message Setup 18 Power Mode 19 Programming Output String 19 4 Maintenance 20 Maintenance Schedule 20 5 Messages and Troubleshooting Mode 21 and Trouble Messages 22 A calculation worksheet 26 Audio amplifier voltage drop calculation 27 Audio am circuit max wire length calculation 28 RS 485 Network topology 28 B template C specifications D 3100471 ISSUE 3 2 1 System Overview and Operation System overview Millennium System Master is a Four Zone Emergency Evacua and Routine Signaling control panel that can be programmed operate in two mode types Master Mode or Satellite Mode In mode the panel provides reliable emergency and non emer notification In addition to signaling notification the panel area and plant wide voice communications for emergency non emergency use See Figure 1 following features are built in 67 field selectable audible tones See Table 1 Audio voice power supervision Microphone and input supervision Up to 4 five second field recordable voice messages Hand held microphone paging Standby power by using EBPS10 Booster Power Supply Up to 64 Satellite units addressable through RS485 network Output Trouble Relays designed for fail safe operation Multiple knockouts for easy cabinet entry LED Alarm Status Indication 40 character LCD display for system status messages Program lockout key Adjustable output volume control Text output capable with Edwards message center signs Master Mode Master mode the panel will be in standby normal operation for either emergency or non emergency keypad or external While there is no keypad or external initiation the panel perform continuous supervision on the following RS 485 net via serial polling of configured devices audio signal output external input channels remote power loss sense micro audio amplifier and STDBY power input when enabled encountered troubles will be posted both visually on the panel screen and audibly from the panel internal piezo buzzer panel initiation of emergency and non emergency activity with the exception of RS 485 polling will occur after seconds of operation from the start of the initiation request will continue regardless of the panel activity state Satellite Mode in this mode the panel will operate the same as in Master except it will not supervise RS 485 network devices It may respond to serial commands from another panel config as a master All supervisory updates will occur once every 30 Operations overview the absence of any alarm supervisory trouble or non emer events the control panel monitors the entire system for panel encounters either an emergency or non emergency the panel conducts the following appropriate output relays K1 K4 associated with input programmed alarm tone voice audio output the appropriate alarm LED on the front panel the appropriate programmed output response for the or external input that signaled the event programmed Dynamic Zone Control event to appropriate serial devices Master Mode only

Related Files