Edwards 860 Series Horn Strobe Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-860-series-horn-strobe-installation-instructions-3649825710.pdf
Type PDF
Size 786.87 KB
Downloads

Text Preview

6 Mount the horn strobe on the mounting plate Figure 1 The inside of the top of the grille has hinges that pass through and engage with tabs on the mounting plate With the of the grille lifted out slightly place the grille over the plate so that the hinges of the grille are in the cutouts Properly seat the grille by pressing the bottom in Fasten the bottom of the grille to the mounting plate by the captive combination drive screw Apply power and activate the horn strobe unit to verify that it is properly Should the unit fail to operate properly do not attempt repair the supplier for replacement a visual inspection and an operational test twice a year voltage current horn current strobe rate per second level output at 10 ft m anechoic chamber environment model VAC Hz mA mA model VAC Hz mA mA 1 fps dBA nominal VDC mA mA 93 at 90 32 relative 32 to 120 0 to 49 ambient temperature 98 at 104 40 relative to 150 to variable ambient temperature The operating voltage to the horn may be continuous or coded as march time or a temporal pattern meeting ISO8201 S3.41 Audible Emergency Evacuation Signal Horn and strobe currents are additive when connected in parallel 867STR AQ 868STR AQ and 869STR AQ potentially timing signals or pulses above 9 kHz and therefore have tested and found to comply with the limits for a Class A digital pursuant to Part 15 of the FCC Rules These limits are to provide reasonable protection against harmful interference the equipment is operated in a commercial environment This generates uses and can radiate radio frequency energy if not installed and used in accordance with the instruction may cause harmful interference to radio communications of this equipment in a residential area is likely to cause interference in which case the user will be required to correct interference at his own expense Changes or modifications to this equipment not expressly by the party responsible for compliance could void the user to operate the equipment Horn Strobe Signal Installation Sheet horn strobes are high quality signals intended for use in cUL signaling applications The strobes flash at 1 fps across their operating voltage range See Table 1 for model numbers and for details Surface Mount Indoor Gray Surface Mount Outdoor Gray Flush or Panel Mount Indoor Gray 1 Models Insert lens color C Clear R Red G Green B Blue Amber The horns are available in two voltages Insert suffix as required 120 VAC AQ 24 V AC DC and wire this device in accordance with applicable national and codes ordinances and regulations and in a manner acceptable the local authority having jurisdiction To reduce the risk of shock do not connect AC or battery power to horn until directed in these instructions To reduce the risk of shock do not tamper with this device when signal circuit is energized Disconnect all power and wait 5 for stored energy to dissipate before handling Select a mounting method as detailed in Figure 1 and install the box using suitable hardware outdoor applications install the weatherproof box using four 1 1 4 32 mm screws and caplugs provided in the enclosed bag Carefully adhere the gasket part number provided in the enclosed parts bag to the box as in Figure 1 Be sure that the hook flange is facing outward as shown in 1 item 10 installation The designation TOP on boxes denotes orientation of box Attach the mounting plate using two 8 32 screws provided with surface box or four 8 32 screws provided with weatherproof The flush box uses two 8 32 screws not provided Bring the signaling circuit field wiring into the electrical box Connect signaling circuit field wires to terminals on horn strobe Figure 2 through Figure 4 Ground in accordance with national and local electrical codes A ground screw is provided with both the indoor and outdoor boxes P 047550 1786 EN REV 07 ISS 08OCT15 2 1 Detailed view in mm in mm in mm in 76 mm or in 92 mm in mm in mm in mm in mm Surface outdoor Weatherproof box Gasket Flush Panel Standard North American 4 in sq 1 1 2 in deep electrical box 52171 with 1 1 2 in 38 mm deep extension ring 53151 or equivalent CAUTION CANADA If using Iberville Commander extension use standard North American box with 2 1 8 in 54 mm extension ring Universal 53171 Surface indoor Knockouts for 1 2 in 13 mm or 3 4 in 19 mm conduit top back Surface box Hook flange Mounting plate supplied Electronic horn strobe Captive combination drive screw Terminal block see Figure 4 2 Wiring the horn and strobe on the same circuit 4 Terminals Applicable voltage source Horn Strobe Polarity must be observed for units operating on VDC 3 Wiring the horn and strobe on different circuits Applicable voltage source Horn Strobe Polarity must be observed for units operating on VDC information C22.2 No 205 464 information contact information see www edwardsfiresafety com 2015 Walter Kidde Portable Equipment Inc rights reserved 2 P 047550 1786 EN REV 07 ISS 08OCT15

Related Files