Edwards 869D-G1 Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-869d-g1-installation-instructions-0798326514.pdf |
---|---|
Type | |
Size | 1.08 MB |
Downloads |
Text Preview
Installation Instructions for 869D G1 Series Polarized Electronic Horn Signal Appliance horns are UL and cUL Listed high quality signals in for indoor or outdoor use It is recommended these products be installed in accordance with the in the latest edition of national and local codes For outdoor use the horns must be in with a weatherproof backbox is recommended that these products be installed in with the requirements in the latest edition of and local electrical codes Table 2 and Figure 1 for specifications 1 Electronic Horns Gray Flush or Panel Mount Indoor reduce the risk of shock always disconnect all power handling the unit Select mounting method as detailed in Figure 1 and the electrical box not supplied using suitable For outdoor applications install the weatherproof ordered separately using four 10 x 1 1 4 mm screws and cap lugs provided in the parts bag Be sure hook flange is facing outward as shown Figure 1 The designation TOP on boxes denotes of box after installation Attach mounting plate using two 8 32 screws with the surface box ordered separately or 8 32 screws provided with the weatherproof box separately The flush box uses two 8 32 not provided Bring signaling circuit field wiring into electrical box CT 203 699 3300 FAX 203 699 3365 CUST SERV 203 699 3078 TECH SERV 3100286 ISSUE 2 2002 1 Detailed View Ground in accordance with national and local electrical A green ground screw is provided with both indoor and outdoor surface boxes the bottom of the grille to the mounting by installing the captive combination drive Connect signaling circuit field wires to terminals on Apply power and activate the horn strobe unit to verify assembly Figures 2 and 3 it is operating properly Mount the horn assembly on the mounting plate 1 The inside of the top of the grille has hinges that through cutouts and engage with tabs on the plate With the bottom of the grille out slightly place the grille over the plate so that the hinges of the grille in the mounting cutouts Properly seat the grille by pressing the bottom in the unit fail to operate properly do not attempt Contact the supplier for replacement a visual inspection and an operational test twice year FOR OUTPUT TONE EMERGENCY FOR TONE 2 Wiring Diagrams 3 Terminal Block Voltage Current Horn Level Output at 10 ft 3.05 m Chamber Environment 2 Specifications DC mA low volume 20 to 24V DC mA high volume 20 to 24V DC dBA peak low volume dBA peak high volume relative humidity 104F 40C 32 to 120F to 49C variable ambient temperature relative humidity 104F 40C 31 to 150F to 66C variable ambient temperature operating voltage to the horn may be continuous or coded such as march time or a temporal pattern meeting ANSI S3.41 Audible Emergency Evacuation Signal Edwards 3100286 ISSUE 2 699 3000 2