Edwards 910 Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-910-installation-instructions-1742869305.pdf
Type PDF
Size 608.32 KB
Downloads

Text Preview

P N P 047550 0725 5 for Phone Page Catalog Number 910 use with telephones having modular RJ11C type jacks For hard wired telephones key systems multiple line phones use Edwards Cat No 913 Hard Wire to Modular Adapter ordered separately in conjunction with the Phone Page and follow the instructions supplied with the adapter connection only to a single line telephone or a key system Not intended for use on line phone service or on coin telephone lines connection to telephone networks using standard plugs and telephone company jacks or equivalent When installed according to these installation instructions Phone Page can be readily disconnected without affecting equipment remaining on telephone network indoor installation only with the Federal Communications Commission FCC in compliance with 68 of FCC Rules and Regulations Listed Type NM Non Monitored Signal Device CT 203 699 3300 FAX 203 699 3365 CUST SERV FAX 203 699 3078 TECH SERV 2001 sure you read and thoroughly understand all instructions before installing this device Cat No 910 Phone Page interfaces with an existing modular jack or hardwire telephone provide for actuation of a supplementary signaling device during the telephone ring cycle The turns off when either the telephone is answered or the call is unanswered and terminated by calling party Phone Page see Figure 1 plugs into a standard 120V AC wall outlet and draws power to the signal directly from the power line A ground type female receptacle is provided on the Page for connection of the signaling device Most any audible or visual signaling device that on 120V AC may be used Modular Duplex Plug Adapter Figure 1 supplied with the Phone Page allows for easy of the actuator to the telephone line A separate modular telephone extension cord a modular plug on each end is required for this connection The required length of the cord depend on your particular installation requirements A 15 foot modular extension cord Cat No 914 also is available from your supplier TELEPHONE INFORMATION sure you can provide the following information to the telephone company if it is requested Phone Number FCC Registration Number Ringer Equivalence Number Ringer Equivalence Number REN allows you to determine the number of devices you can to your telephone line and still have all the devices ring when your telephone number is called most but not all areas the sum of all RENs for all devices connected to one line should not 5.0 To be sure of the number of devices you can connect to your line contact your local company the Phone Page damages the telephone network the telephone company will notify you that it temporarily disconnect your service if they feel such action is necessary If you feel the is unwarranted you have the right to bring a complaint to the FCC telephone company may make changes in its communications facilities equipment opera or procedures when such action is required If these changes render the Phone Page with the telephone company facilities the telephone company will provide enough notice so that you can make the necessary changes to maintain uninterrupted service are three possible locations for installation of the Modular Duplex Plug Adapter as in Figure 2 The Duplex Adapter can be installed on the telephone junction box 1 on the Phone Page Example 2 or on the telephone Example 3 Determine method best suits your installation requirements and install the Duplex Adapter one end of a separate modular telephone extension cord not supplied into a receptacle the Duplex Adapter Then plug the other end of the cord into the jack in either the bottom the Phone Page Ex 1 or 3 or into the jack in the telephone junction box Ex 2 Phone Page must be installed on a 120V AC ground type duplex wall outlet This outlet be located close to the are where the signaling device is to be located so that the device be directly connected to the Phone Page without the use of an extension cord If a type outlet is not available or is not located such that direct connection of the signal possible you should contact a licensed electrician to have a new outlet installed A screw provided with the Phone Page for securing the unit to the outlet of the faceplate from the wall outlet is not required and should not be attempted as would present a risk of electrical shock the screw from the center of the wall outlet faceplate DO NOT REMOVE THE the Phone Page into the lower receptacle of the duplex outlet the Phone Page to the outlet by installing the screw supplied with the Phone through the hole in the top of the Phone Page backplate and into the screw hole the center of the faceplate signaling device to be connected to the Phone Page must be rated for 120V AC operation signal load must not exceed 10 amps resistive 300 Watts tungsten or 4 amps inductive more than one signaling device is to be used connect all devices in parallel Typical that may be used include Edwards horns bells and flashing lights and other signaling devices as well as household type lamps Refer to the separate sheet with the Phone Page for a list of recommended Edwards signaling devices the power cord from the signaling device directly into the 120V outlet on the front of the Page as shown in Figure 3 The use of extension cords and plug in type outlet to connect the device to the Phone Page is not recommended If the signaling includes a power switch turn the switch to the ON position so that the device will when the telephone rings and Repair the Phone Page should fail to operate properly disconnect it from the telephone line and see if problem is due to the telephone line or the Phone Page not disassemble this device It does not contain any servicable components the problem is in the Phone Page remove it from service and return it to your local Edwards Contact our customer service department at 203 699 3367 for a distributor in your Input Voltage 120V AC 50 60 Hz Voltage Limits 102 132V 50 60 Hz Output Load 10 Amps Resistive 4 Amps Inductive 300W Tungsten Requirement not including signaling device load 0 Watts 0.67 Watts at 90V Signal Voltage Limits 90V AC 30 20 Hz 0.33 Duty Factor Characteristics to Ring Impedance 11,705 ohms Resistance Infinite 1 Box Line Extension Cord Not Supplied 2 Box Line Telephone Cord Supplied 3 Box Line AC Duplex Outlet Plug AC Duplex Outlet Plug Telephone Cord Supplied AC Duplex Outlet Plug 2 Connecting Phone Page to Telephone Line Page Cord Signaling Device Light type in back unit for to AC outlet No 910 Page screw securing unit wall outlet AC receptacle connection of device s

Related Files