Edwards CS405 Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-cs405-installation-instructions-4759381260.pdf
Type PDF
Size 661.88 KB
Downloads

Text Preview

Installation Instructions for Strobe Signal Appliance strobes are high quality notification appliances intended for public applications in accordance with the latest edition of NFPA 72 Fire Alarm Code It is recommended that these products be in accordance with the requirements in the latest edition of and local fire alarm and electrical codes The 15 75 cd model and 110 cd model strobes are suitable for indoor or outdoor applications outdoor use the strobes must be installed with a weatherproof model 449 strobes are self synchronized to flash at 1 fps across their full voltage range Studies show that people with photosensitive may experience a photoconvulsive response from random of light This risk is minimized with these strobes The strobe on any existing 2 wire signal circuit Separately installed sync modules are not required of less than 200 milliseconds will be maintained for no than 60 hours supervision followed by 30 minutes in alarm Figures 3 and 4 for product specifications This device will not operate without electrical power As fires cause power interruptions discuss further safeguards with your local protection specialist reduce the risk of shock always disconnect all power before handling unit reduce the risk of shock do not tamper with unit when circuit is energized all power and allow 5 minutes for stored energy to dissipate handling indoor mounting select a Standard North American 2 gang X 1 1 2 mm deep electrical box 52151 Series or equivalent For outdoor use a weatherproof model 449 backbox Install the electrical using suitable hardware signaling circuit field wiring into the electrical box Electrical supervision requires wire run to be broken at each Do not loop signaling circuit field wires around terminals this unit to a signaling circuit that outputs a constant not voltage To ensure proper unit function polarity must be Refer to Figure 2 for wiring connections For additional connection details see the installation instructions supplied with control panel When connections are complete mount the unit onto the electrical box as indoor mounting secure the unit using two Phillip head screws Complete the enclosure by installing two hole plugs Number P 038845 0019 supplied into the two unused holes the back plate outdoor mounting secure the unit using the four Phillip head supplied Discard the two plastic caps supplied power and activate the unit to verify that it is operating properly Should the unit fail to operate properly do not attempt repair the supplier for replacement a visual inspection and an operational test twice a year or as directed the local authority having jurisdiction VIEW MOUNTED VIEW MOUNTED 1 Detailed View Listed Fire Alarm Panel signal VIEW MOUNTED offered in various styles and languages Order either the Series Ceiling or LKW Series Wall Lens Kit Separately FIRE wall orientation is supplied with the strobe resistor with control panel This unit is designed to be used on signal circuits that output a constant voltage of 20 24 VDC Do not connect this unit to a coded or voltage Electrical supervision requires wire run to be broken at each terminal Do not loop signaling circuit field wires around strobe terminals 2 Connecting Strobe Units with Terminal Blocks voltage Vdc current figure 3 rate per second 1 fps synchronized output cd 1971 7A cd wall 1971 8A cd wall cd ceiling cd ceiling 1638 7A cd 1638 8A cd environment relative humidity 86 30 32 to 120 to 49 variable ambient temperature relative humidity 86 30 40 to 151 to 66 variable ambient temperature with box The 8A strobe may be used in sleeping areas When used in sleeping the strobe must be wall mounted not less than 24 in 601 mm from ceiling no more than 16 feet 4.88 m from the pillow Distance to the ceiling is from top of signal lens 387627 1996 This equipment has been tested and found to comply with the limits for a A digital device pursuant to Part 15 of the FCC Rules These limits are to provide reasonable protection against harmful interference when the is operated in a commercial environment This equipment generates and can radiate radio frequency energy and if not installed and used in with the instruction manual may cause harmful interference to radio Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the at his own expense Changes or modifications to this equipment not expressly approved by party responsible for compliance could void the user authority to operate the strobes strobe 15 75 cd red strobe 110 cd red Voltage DC Voltage Full Wave Rectified Inrush Current 24 Vdc 7.6 A for Inrush Current 24 Vdc 6.8 A for than 50 microseconds than 50 microseconds Voltage DC Voltage Full Wave Rectified Inrush Current 24 Vdc 7.8 A for Inrush Current 24 Vdc 6.8 A for than 50 microseconds than 50 microseconds Use the average current rating to establish the maximum number of strobes wire gauge and standby power requirements Consult the to determine the peak current effects on the system 3 V I Curves cd Model cd Model cd cd 15 30 45 60 75 90 30 50 60 70 80 d 30 50 60 70 80 d 125 175 125 150 175 d d 4 Strobe Light Output Distribution Patterns 387627 1996 SIGNAL BUILDING SYSTEMS CORPORATION FL 941 739 4300 Fax 941 753 1806 CT 203 699 3000 Fax 203 699 3075 SOUND CANADA 519 376 2430 Fax 519 376 7258 CANADA 905 270 1711 Fax 905 270 9553 Minimum Output

Related Files