Edwards Data Sheet E-FSA64 Analog Addressable Life Safety System

File Preview
File Preview
Click below to download for free

Text Preview

Edwards Signaling Catalog u Fire Alarm Panels Safety System Edwards Signaling E FSA64 life safety system offers the reli of analog addressable fire detection for small to mid sized Built to provide years of trouble free service this benefits building owners and installers with rotory device optional Ethernet connectivity and a full line of easily option cards and modules Comes standard with one loop that supports up to 64 analog devices of any type and two Class B NACs Form C contacts for alarm and trouble Form A for supervisory Rotory addressing Optional Ethernet port for diagnostics programming and a E FSA64 provides one Class B analog addressable device that supports up to 64 device addresses and two Class B Appliance Circuits NACs Optional Class A device is available with the use of a module E FSA64 supports a wide range of accessories and related including Intelligent modules and pull stations Intelligent detectors and bases Remote annunciators Option cards that expand system capacity and extend sys capabilities of system reports Two programmable switches with LEDs and custom labeling Supports horn silence over two wires and UL 1971 compliant synchronization Optional Class A wiring Supports up to eight serial annunciators LCD LED only and interface Can use existing wiring for most retrofit applications Upload download remotely or locally Two level maintenance alert reporting Pre alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening seismic Importance Factor 1.5 1 of 8 D A T A S H E E T S85005 0131 to be used for installation purposes Issue 5 01 01 07 E FSA64 life safety system is a reliable analog addressable for small to mid sized buildings Analog Addressable Tech delivers the benefits of flexible system installation while a and easy to operateuser interface makes panel operation and maintenance quick and intuitive you can count on inherent fault tolerant characteristics of Analog Address Technology boosts the reliability of E FSA64 systems When with E Series smoke and heat detectors this system a level of dependability not previously available for small to applications All E Series systems are built to exacting reliability benchmarks and meet ISO 9001 standards for in addition to agency listings for dependability built right in fully programmable front panel switch LED combinations pro an added measure of flexibility Their slide in labels take the out of custom applications and present a clean finished front panel provides an operator inter as well as all the neces controls for front panel A large back lit LCD displays status event details programming prompts tactile control buttons easy to see in low light and bright multi LEDs offer at a glance indication for retrofits E FSA64 is particularly well suited to retrofit applications All are made over standard wiring no shielded cable This means that in most situations existing wiring can be to upgrade a legacy control panel to E FSA64 technology the expense or disruption of rewiring the entire building Silence buttons with a difference NACs are configurable to fully support Edwards notifica appliances These devices offer precision synchronization of to UL 1971 standards Enabling this feature allows con horns to be silenced while strobes on the same two wire continue to flash until the panel is reset remote annunciation annunciation is a strong suit of the E FSA64 Up to eight can be installed on a single system Compatible an include a range of LED and LCD models that provide or point annunciation as well as common control capabili E FSA64 also supports graphic annunciation with optional RA Annunciator interface modules Each interface provides control indicators and 32 LEDS Consult the Ordering section for details complete line of accessories E FSA64 life safety system is supported by a complete line of detectors modules and related equipment the Ordering Information section for details a system reset the panel and remote annunciators during active trouble supervisory or alarm event and new event activations mode Silences active notification appliances Signal Silence a second time turns NACs back Disables or enables dialer set to modem only Disables or enables the alarm relay mode Moves the cursor to the left mode Toggles between programming mode Moves the cursor to the right mode Retrieves a programming option sub and toggles between a programming option mode Advances to the previous event mode Moves the cursor up mode Advances to the next event mode Moves the cursor down mode Displays selected event details mode Retrieves a programming option sub or jumps to the Save function in the menu mode Enters the selected data into the system mode Exits the detailed information display mode Exits the current menu level mode Clears the current entry mode Enters the menu mode mode Exits menu mode a space such as a space between words mode Pressing a button once enters the number the button Pressing the button twice enters the value buttons can be programmed to control or a device zone or Panel NAC The buttons can labeled with a slip in insert arrow arrow arrow arrow 2 of 8 D A T A S H E E T S85005 0131 to be used for installation purposes Issue 5 Operation Options LEDs Alarm Power keys fail delay resound inhibit after turn on signal start start banner notification LED On steady when there is an active LED Flashes when there is a fault on a circuit or system component or when circuit is disabled LED On steady when there is an active event LED On when the panel has AC power LED Double flashes when there is a dis circuit alarm relay or remote annunciator LED On steady during an active ground LED Flashes when performing an audible test Steady indicates a silent test LED Indicates that detector needs servic LED On steady indicates that NAC cir are turned off but the panel is still in alarm LED On steady indicates that the dialer disabled or that the alarm relay is enabled or when the dialer is set to modem only LED Programmable or French or Canada Off premise notification of an AC power failure immediate to 15 hours Delays the off premise notification of AC power failure by the time period selected NACs resound each time a device in the zone into alarm even if they were silenced Inhibits the NACs from turning on again after were silenced when a second device in the goes into alarm Panel reset is operational immediately minute Panel reset is inhibited for one minute Allows immediate silencing of signals from an condition using the Signal Silence button to 30 minutes Delays the silencing of signals an off normal condition by disabling the Signal button for the time period selected time for daytime sensitivity time for nighttime sensitivity MM DD YYYY DD MM YYYY text for line one and line two Each line is of up to 20 characters When a device is a member of a zone only zone information is sent to the LCD display printer and dialer Zone information is sent to the LCD and LEDs Device information is sent to the and dialer Only device information is reported life safety systems are simple to set up yet also offer features that put these small building panels into clas

Related Files