Edwards Data Sheet E-FSC Conventional Fire Alarm Panel

File Preview
File Preview
Click below to download for free

Text Preview

Edwards Signaling Catalog u Fire Alarm Control Panels Fire Alarm Panels E FSC fire alarm family consists of 3 5 and 10 zone conven fire alarm control panels an integrated DACT Dialer serial modules and serial remote relay modules All of these are microprocessor controlled The E FSC family is for both new and retrofit installations alike incorporates features designed to simplify installation opera and maintenance These include front panel programming one walk testing and selectable IDC and NAC types In addition used with Edwards CleanMe compatible smoke detectors provides analog type features such as remote maintenance and automatic drift compensation that reduces false alarms simplifies maintenance calls and E FSC1004 panels support Class A operation by pairs of on board initiating curcuits IDCs or notifica circuits NACs to provide the necessary Class A circuits For the E FSC1004 comes factory set to support 10 Class IDCs and four NACs But it can be field configured to provide Class A IDCs no Class B IDCs and two Class A NACs or other combination of circuits that fall within the circuit pairing B IDCs A IDCs B NACs A NACs Power power to 10 to 5 to 4 to 2 amps amps to 5 to 2 to 2 amps amps supported supported amps Class A operation will reduce the number of available Class B IDCs and or depending on the panel configuration See Specifications on page 5 for Features Available in 3 5 and 10 IDC models IDC or NAC pairs convertible to single Class A circuits 10 and IDC panels only CleanMe provides remote annunciation if a detector drifts out UL ULC limits reducing the chance of a false alarm Combination Waterflow and Supervisory IDCs reduces wire and counts NACs programmable by zone and individually selectable for continuous temporal outputs or coded Front panel programmable simplifies installation and servicing Optional fully integrated DACT Dialer for remote PC Genesis option allows precision synchronization and audible over two wires without additional modules On board relays for Alarm Supervisory and Trouble Optional serial bus relay modules are programmable for com or zone activation Optional serial bus remote annunciator family One person walk test audible or silent Expandable power supply on 10 IDC panel reduces booster costs Trim ring available for semi flush mounting Supports 2M 2400 500 and 700 series detectors to 7.0 amps 1 of 8 D A T A S H E E T S85005 0126 to be used for installation purposes Issue 2 LED Display following system LEDs display the panel status Alarm panel is in the alarm state Trouble panel is in the trouble state Supervisory panel is in the supervisory state Power indicates the status of the AC power source Disable indicates when any IDC NAC relay or the DACT is Annunciator Trouble indicates trouble on the remote an Battery Trouble indicates battery or charging problems Ground Fault indicates a short between any panel circuit Walk Test indicates that one or more IDCs are in the walk bus ground mode Alarms Silenced indicates that the panel is in the alarm with one or more NACs silenced Waterflow indicates that one or more circuits have detected active waterflow switch Service Detector indicates the presence of a dirty detector Remote Disconnect indicates off site communication has disabled IDC has a disable switch and three LEDs Alarm red indicates that the IDC is in the alarm state Trouble yellow indicates that the IDC is in the trouble state is disabled when flashing Supervisory Monitor yellow indicates that the IDC is in the state or the monitor state when flashing NAC also has a disable switch and a trouble disable LED indication with the DACT Dialer installed dialer LCD display provides two lines x 16 characters of For programming the top line displays the programming and the lower line displays the selected option All system are displayed on the LCD with custom zone messages normal operation the LCD will display any off normal con present in the panel provides smoke and fire detection occupant notification off premises signaling for small to medium sized buildings IDC can be configured for either Class B or Class A opera and one of eight operating modes Alarm or without smoke detector verification including of contact devices Waterflow Alarm Waterflow Alarm Supervisory Combination IDC Supervisory Latching non latching Monitor non alarm or supervisory Signal Silence Drill Cross zoning may also be configured for either Class B or Class A opera 5 and 10 zone panels Additionally NACs can be individually for one of six outputs These are Genesis Genesis silenceable Continuous Temporal Coded and City Tie Genesis selection allows independent horn control over two and provides precision synchronization for Genesis devices without the need for a Genesis Signal Master accessory configured for Genesis notification appliances E FSC Silence function will silence connected Genesis audible but Genesis strobes will remain active until the panel is When Genesis Mode is selected both the horns and strobes Genesis and Enhanced Integrity notification appliances will be across all NACs zones may be selected for either latching non latching operation with intelligent features a conventional price combined with Edwards compatible smoke E FSC provides intel features at a conventional If a CleanMe detector out of the UL ULC sensi range Edwards Signaling remote maintenance sends an alert to E FSC control panel This reduces the chance of a alarm and simplifies service In addition CleanMe compatible smoke detectors have drift compensation that extends the time between clean If cleaning is ever necessary it is literally a snap with Edwards exclusive replaceable optical chamber 2 of 8 D A T A S H E E T S85005 0126 to be used for installation purposes Issue 2 AC block fuse transformer wiring block 120 Vac 15 A 60 Hz branch circuit 230 Vac 15 A 50 60 Hz branch circuit wrap connector communication fully integrated E FSC DACT dialer is available for reporting to a monitoring facility The DACT also supports uploading downloading of system configuration status and event history DACT is programmable for either single or dual line opera It also supports split and dual reporting for two digital alarm DACT brings additional features to the panel including a alphanumeric LCD display remote PC programming an event history log Annunciators and Relays serial bus standard on all E FSC models is another installation This circuit allows the connection of Remote System FSRSI Remote Zone Indicators FSRZI A FSRZI SA and Relay Modules FSRRM24 over a four wire data and power Annunciator and relay modules can be installed up to 1,000 from the panel on 18 gauge wire are also available for City Tie CTM and Reverse Polarity connections Relay Module optional DACT Dialer is a multi module that provides commu modem capability and LCD functions Its primary function as a Digital Alarm Communica Transmitter DACT As a DACT it event messages to a Digital Communicator Receive

Related Files