Edwards Data Sheet Genesis Wall Speakers and Speaker Strobes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-data-sheet-genesis-wall-speakers-and-speaker-strobes-5219704638.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
Genesis Speakers Strobes EG4 Series Signaling Catalog u Speakers pending Genesis line of life safety signals are the smallest most audible visible emergency signaling devices in the world no more than one inch from the wall Genesis speakers speaker strobes blend with any decor safety appliances feature textured housings in architecturally white or traditional life safety red to patented breakthrough technology Genesis strobes do require bulky specular reflectors Instead an exclusive design and conditions light to produce a highly controllable pattern feature selectable candela output with a conven switch on the bottom of the device The candela remains clearly visible even after final installation Genesis speakers include a DC blocking capacitor to allow supervision of the audio distribution circuit The speaker its sealed back construction provides extra durability and audibility Features Unique low profile design The most compact UL ULC listed speaker strobe available Ultra slim protrudes a mere one inch from the wall Attractive appearance no visible mounting screws Field configurable no need to remove the device 1 or 2 watt operation and selectable candela output with convenient switches that remain visible even after the unit is installed Unparalleled performance most even light distribution loud 90 dBA output ensures clear crisp audio Exclusive FullLight strobe technology produces the Precision timing electronics meet tough new synchronizing standards for strobes when used with compatibile modules Optional field configurable temporal strobe output 25 Vrms and 70 Vrms models available all supplied with a DC blocking capacitor for audio circuit supervision Easy to install Fits all standard 4 square electrical boxes with plenty of behind the signal for extra wire no extension ring or trim plate needed 18 12 AWG terminals ideal for long runs or using existing wiring 1 of 4 D A T A S H E E T S85001 0549 to be used for installation purposes Issue 10 Application suggested sound pressure level for each signaling zone with alert or alarm signals is a minimum of 15 dB above the ambient sound level or 5 dB above the maximum sound having a duration at least 60 seconds is greater This measured 5 feet 1.5 m the floor in anechoic chamber Sound Output dBA two watts Application clear lensed strobes are UL 1971 listed for use indoors as public mode notification appliances for the hearing Prevailing codes require strobes to be used where ambi noise conditions exceed specified levels where occupants use protection and in areas of public accommodation Genesis strobes meet UL synchronization requirements within milliseconds over a two hour period when used with a syn source Synchronization is important in order to avoid sensitivity Configuration speakers may be set for 1 or 2 watt operation The setting is visible through a small window on the bottom the device and is changed by simply sliding the switch until the setting appears in the window The speaker does not have be removed to change the wattage speaker strobes feature selectable candela output The setting is visible through a small window on the bottom of device and is changed by simply sliding the switch until the setting appears in the window The speaker strobe does have to be removed to change the output the Candela Switch and the switch to set desired operation change strobe to temporal mode cut JP1 switch switch View speaker strobes may also be configured for temporal This battery saving feature is intended for private mode only To set the device for temporal flash snip the circuit as shown in the Jumper Locations diagram above the distance from signal to the ear will cause a 6dB in the received pressure level The effect depends on acoustic properties materials in the space the power output a device e g a speaker 1W to 2W will in the sound pressure by 3dBA 1.5m 3.05m Series Cone Speaker strobe and Mounting models are intended for indoor wall mounted applications only and speaker strobes are flush mounted to a North 4 square electrical box 21 8 54 mm deep or a Euro 100 mm square box Signals may be surface mounted to a surface mount box see ordering information for details tabs at the top of the signal unlock the cover to facilitate The shallow depth of Genesis devices leaves room the signal for extra wiring Once installed with the cover in no mounting screws are visible electric box m m plate Color matched mount box recommends that these speaker strobes always be in in accordance with the latest recognized edition of national local codes Refer to installation sheet for mounting height These devices will not operate without electrical power fires frequently cause power interruptions we suggest you discuss safeguards with your local fire protection specialist 2 of 4 D A T A S H E E T S85001 0549 to be used for installation purposes Issue 10 A 1971 cd cd cd cd wiring is connected to Genesis signals with terminals that ac 18 to 12 AWG 0.75 mm to 2.5 mm wiring Equivalent Rating output cent of UL rating versus angle Of Candela H Spec Of Candela V Spec 5 UL required candela light output name plate maximum operating current RMS mA rating Vdc Vfwr current milliamps average RMS rating Vdc Vdc Vdc Vfwr Vfwr Vfwr output switch settings for UL 1971 listed models are selectable by numeric candela 188 159 124 264 225 200 245 203 157 342 283 251 101 86 69 147 130 115 78 65 53 106 95 84 Speakers and Speaker Strobes wall mount only Connections environment Listings Volts Taps Output Cone Output Rating Operating Voltage Flash Rate Flash Synchronization or white textured UV stabilized color impregnated engineered plastic 6.5 165 mm Width 5 127 mm Depth to wall 1 25 mm North American 4 square box 2 1 8 54 mm deep model EG4B white or EG4RB red surface mount box terminals separate polarized inputs for speaker and strobe 18 to 12 AWG 0.75 mm to 2.5 mm wire F 0 49 C ambient temperature 0 93 relative humidity 1971 UL 1638 UL 1480 ULC S526 ULC S541 CSFM MEA FM pending models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule VRMS or 70 VRMS See ordering information W 89 dBA 1 W 86 dBA W 83 dBA W 80 dBA frequency response 250 to 5,000 Hz for voice intelligibility 4 inch 102mm mylar cone sealed back construction 1971 ULC S526 selectable 15 cd 30 cd 75 cd or 110 cd output 1971 15 cd fixed 15 75 cd models 1638 ULCS526 75 cd fixed 15 75