Edwards Data Sheet Intelligent Detectors and Bases

File Preview
File Preview
Click below to download for free

File Data

Name edwards-data-sheet-intelligent-detectors-and-bases-0176493852.pdf
Type PDF
Size 1.09 MB
Downloads

Text Preview

Edwards Signaling Catalog u Intelligent Initiating Bases E PD E PHD E PDD B4U RB4U IB4U SB4U Features Optical smoke heat and multisensor models available Field replaceable optical chamber Highly stable design Compatible standard relay isolator and audible bases Head and terminal base tamper resistent design for fast instal and security Self diagnostic capability with on board storage of data Optical detectors feature automatic rate compensated sensitiv adjustment as well as dirty sensor warnings Manufactured to strict international ISO 9001 standards Low profile aesthetically pleasing design intelligent addressable detectors are meticulously engi to deliver high perfor mance features superb reliability and quality With their highly stable design these detectors air movement caused by heating and air conditioning making reliable performers ideally suited to modern building interiors installation and maintenance advantages of Edwards intel detectors add value throughout their service life The head terminal base design makes short work of installation and opera tions A plastic breakout on the detector optionally pre vents removal from the base except with a tool bi colored LED flashes green for normal operation and red in alarm thus eliminating much of the guesswork when to detector status The houses a replaceable optical sensing chamber that particles produced by smoke The houses a replaceable optical sensing chamber detects smoke as well as a fixed temperature sensor that heat The detector analyzes data from both sensors to when an alarm is initiated The duct detector prevents smoke from circulating the building see data sheet S85001 0584 The is a selectable rate of rise or fixed temperature heat with a fixed alarm threshold of 135 F 57 C detectors feature comprehensive self diagnostic capability and E PHD optical detectors continuously adjust their sen reference value to compensate for changes in the environ such as the presence of dirt temperature and humidity detectors issue a dirty sensor warning when they reach preset limit reducing the chance of a nuisance alarm 1 of 6 D A T A S H E E T S85001 0592 to be used for installation purposes Issue 2 details Application intelligent analog device houses an optical chamber that detects smoke as well as fixed temperature sensor that detects heat The analyzes sensitivity reference values from sensors to determine when an alarm is initiated The E PHD capable of performing comprehensive self diagnostics and stor the data detector continuously adjusts its sensitivity reference value on fluctuating environmental conditions such as the pres of dirt humidity or changes in temperature When the detec has adjusted its sensitivity reference value to its maximum limit issues a dirty sensor warning allowing enough of a margin for personnel to clean the detector before it goes into condition E PHD combines the suitability of optical sensing for slow fires with the sensitivity of fixed temperature detection for flaming fires to arrive at a solution that responds reliably to the range of fire types A sophisticated algorithm processes from both sensors over time so that an alarm is only reported conditions precisely match the signature of a fire This elimi the shortcomings of single sensor optical and heat detec and significantly reduces the risk of nuisance alarms intelligent analog device can be configured as a 135F fixed temperature heat sensor or a rate of rise with fixed temperature The sensor monitors the temperature of the air and whether an alarm should be initiated The E HD is of performing comprehensive self diagnostics and storing data to its advanced thermistor technology the E HD detector ideal for sensing fast flaming fires and for applications where detection is inappropriate It is particularly well suited to such as laundries and industries where fluctuations in ambi temperature is expected detector prevents smoke from circulating the building see data sheet S85001 0613 intelligent analog device uses an optical sensing to detect smoke The detector analyzes reference values gathered by the sensor determine when an alarm is initiated The E PD is of performing comprehensive self diagnostics and storing data detector continuously adjusts its sensitivity reference value on fluctuating environmental conditions such as the pres of dirt humidity or changes in temperature When the detec approaches its preset sensitivity reference value threshold it a dirty sensor warning allowing enough of a margin for personnel to replace the optical chamber before it into trouble condition to its high performance optical sensing chamber the E PD quickly and reliably to a wide range of fire types espe slow burn ing fires fuelled by combustibles typically found in multi use buildings The E PD detects extremely small and triggers an alarm at the first sign of smoke Indication detector provides a tri color LED that shows its status Normal Green LED flashes Alarm active Red LED flashes Addressing a screwdriver to adjust the two rotary switches on the front the module Set the TENS rotary switch 0 through 12 for the and 100s digit and the ONES rotary switch for the 0 through digit 5 9 screwdriver here device address 21 set TENS rotary switch to 2 and set ONES rotary switch to 1 to the Specifications Table for available address numbers 2 of 6 D A T A S H E E T S85001 0592 to be used for installation purposes Issue 2 Bases in square electrical box IB4U Isolator Detector Base is designed to prevent an entire A communications loop from being disabled when a short occurs This is accomplished by isolating the part of the containing the short from the remainder of the circuit out out next bracket base assembly ring in in IN IN in in out DATA OUT out OUT the detector to the base by rotating the detector clock until it snaps into the locked position head can be removed by turning it counterclockwise If the head must lock to the base break away the tab shown below using a pair of pliers of detector then remove the detector head insert a small into the slot on the side of the base press in while simultaneously turning the head counterclockwise tab B4U digital Standard Detector Base features twist and lock installation and is compatible with with E Series analog The base does not require a separate address because shares the address of the device it is connected to RB4U Relay Detector Base is designed to add relay func to the listed compatible detectors Form C latching relay are included for the control of appliances such as door fans dampers etc The relay base will activate when the plugged into it alarms and can also be programmed to from any other input device on the system LED wire not Ohms in in out out next in in Description in and SLC out in used used next out out Description used LED out LED COM N C Description Normally open Common Normally Closed in in out out IN IN OUT OUT Bases do not require separate addresses because they share the address of the device it is connected to Wire in accordance with NFPA 70 National Electrical Code Be sure to obser

Related Files