Edwards Data Sheet TS7 Series Conventional Smoke Detectors & Bases
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-data-sheet-ts7-series-conventional-smoke-detectors-bases-2368509417.pdf |
---|---|
Type | |
Size | 750.28 KB |
Downloads |
Text Preview
Edwards Signaling Catalog u Conventional Initiating and Four Wire Smoke with Bases Series Terminal bases included TS7 Series features photoelectric smoke detectors with an to install and maintain head and terminal base design photoelectric smoke detector heads are self diagnostic and field replacable optical chambers They feature automatic compensation which adjusts the sensitivity if the detector be dirty over time greatly reducing the chance of a nuisance the TS7 ever does drift out of its UL Listed sensitivity range or internal diagnostics the alarm LED flashes once a second indicate trouble This meets NFPA 72 field sensitivity testing without the need for external meters Additional information is activated by applying a magnet near detector integral reed switch This initiates a self diag nostic and provides rapid LED visual indication of sensitivity level can be recorded or if service is required Features Two wire head and terminal base models packaged together Self diagnostic capabililty continually monitors operation Built in drift compensation Field replaceable optical chamber Low profile design blends in with the environment Available with integral heat detectors Meets NFPA 72 field sensitivity testing without the need for meters Extensive 2 wire compatibility listings 12 24VDC 1 of 2 D A T A S H E E T S85001 0600 to be used for installation purposes Issue 2 us 1 800 336 4206 www edwardssignaling com Signaling is EDWARDS brand Farm Glen Boulevard CT 06032 Canada contact Chubb Edwards Email inquiries chubbedwards com Web www chubbedwards com 2013 UTC Fire Security Americas Inc All rights reserved subject to change notice Edwards is part of UTC Controls Security a unit of Technologies Corporation ripple peak to peak standby current 24V alarm current 24V Sensitivity temperature humidity range immunity LED output current compensation adjustment Sensor Ratings wind velocity wiring size test input voltage time two wire compatibility identifier head dimensions height head and base 33VDC non polarity sensitive Vp p up to 60mA max if not limited by control panel 0.37 1.00 120 0 49 95 Non condensing min 0 1000MHz min 8.5mA max max 135F 15 721UT AWG 100ohm max max second max 711U 711UT 721UT S00 all bases head and base D x 1.75 H 10cm x 4.44cm H 5cm 268 FM CSFM MEA approved under 711U 711UT 741U 741UT heads 701U 702U bases Information wall mount photoelectric smoke detector 2 wire 6 3 terminal 12 24VDC Three terminal base 701U photoelectric smoke detector 2 wire fixed rate of heat remote alarm trouble LED 12 24VDC Six terminal base Replacement optical block cover for all photoelecric models package of 10 in a Can aerosol spray for functional testing of smoke detectors in a Can extension tube S10A S10A 2 of 2 D A T A S H E E T S85001 0600 to be used for installation purposes Issue 2