Edwards E-FSA250 Series Catalog Page
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-e-fsa250-series-catalog-page-1608429753.pdf |
---|---|
Type | |
Size | 1.28 MB |
Downloads |
Text Preview
Addressable Fire Alarms Series Edwards Signaling E FSA250 life safety offers the reliability of analog addressable detection for small to mid sized applications for long service this system offers rotary addressing optional Ethernet connectivity a full line of easy to configure option cards modules E FSA250 provides one Class A or Class B device loop that supports up 127 devices A second 127 point loop may be to the E FSA250 to expand total system to up to 254 device addresses The panel four Class B NACs that can be config as two Class A NACs E FSA250 supports a wide range of and related equipment including modules and pull stations intelligent and bases remote annunciators and cards that expand system capacity and system capabilities and Specifications 127 expandable to 254 analog addressable Product and bases A for supervisory devices and system reports labeling 1971 compliant strobe synchronization and graphic interface to 49 Cards panels are supported by a complete line of modules and related equipment that enhance and extend system capabilities Option cards plug directly into the control panel main board or are connected to it with a ribbon cable After installation terminals remain accessible cabinet provides ample room for wire routing keeping wiring neat at all times Ethernet Interface Card SA ETH card provides a standard 10 100 T Ethernet network connection for connect to an intranet a local network or the Internet card can be used to download configuration from the FSA CU to the panel over network Ethernet card is installed on the plastic and connects to the main circuit board a ribbon cable Loop Expander Card XAL127 Loop Expander Card provides an device loop on the control panel The expands the control panel device capacity 254 total device addresses 127 per loop card is compatible with Class B or Class A It is compatible with E FSA250 control only the main circuit board Dialer SA DACT provides communications between control panel and the central station over a line system It transmits system status events to a compatible digital alarm receiver over the public switched network The dialer is capable of single or split reporting of events to two different and telephone numbers The modem of the SA DACT can also be used for TEMP Fire Alarms Series and downloading panel configuration and current status to a PC running the SA DACT queues messages and transmits based on priority alarm supervisory trouble monitor Activations are transmitted before SA DACT is installed on the plastic assembly connects to the main circuit board via a ribbon RS 232 Interface SA 232 card provides an RS 232 interface E FSA250 panels It can be used for connect a printer to the control panel to print system The card also can be used for connecting computer to download a configuration program the FSA CU to the control panel RS 232 card is installed on the plastic and connects to the main circuit board a ribbon cable Information Wiring cable network B Wiring Loop Expander Card Wiring 1SEC 1 PRI card 1SEC 1PRI card A Wiring Wiring black wire white wire red wire card Line line 2 line 1 wall jack cables jacks Line dialer phone connect connectors the dialer circuit Phone 1 connects connector J4 phone line connects to J1 Information Safety System Panel 254 2 Class A or B each loop up to 127 device No Class B or Class A A each Class B or Class A A each Class B or Class A A each Class B or Class A A each NAC Power Power A total DC DC at 0.5 A at 0.5 A A total DC DC at 0.5 A at 0.5 A A total DC DC at 0.5 A at 0.5 A A total DC DC at 0.5 A at 0.5 A DC 1 A load DC 1 A load DC 1 A load DC 1 A load Annunciator Cabinets Accessories Annunciator Enclosure key with plexiglass window for one or RLED C Annunciator Enclosure key with plexiglass window with for 2 of either RLCDx RLEDx RLED24 Annunciator Enclosure key with plexiglass window with for 3 of either RLCDx RLEDx RLED25 enable or disable of common on RLCD or RLED units Mount Box for R Series and diagnostics utility No Fire Alarms Series Mount Trim Black Cards Line Dialer Modem supports ID SIA DC 05 mounts in on base plate Port RS 232 for connection printers and computers mounts in to base plate Port Slave mounts in cabinet base plate Expansion Module Adds second 127 devices to E FSA250 for a capacity of 254 points Mounts in on main board Annunciator Module 16 groups LEDs per group with insertable Mounts in cabinet on systems Annunciator 4X20 LCD and Indicators for displaying system box White housing Annunciator 4X20 LCD Indicators and Common for displaying system status White housing Annunciator Common Indicators displaying system status common 16 groups w 2 LEDs each electrical box White housing Annunciator Zone expander groups of 2 LEDS each for display alarm and trouble Each with custom box White housing Annunciator Driver provides for common indicators and 32 zones as well as inputs for switches Provided with a snap for mounting in custom graphic No Fire Alarms Series and Dimensions Shipping lb