Edwards E-FSC Series Technical Reference Manual

File Preview
File Preview
Click below to download for free

File Data

Name edwards-e-fsc-series-technical-reference-manual-0953124876.pdf
Type PDF
Size 2.15 MB
Downloads

Text Preview

Series Technical Manual 3101175 REV 03 REB 25JAN13 and information 2013 UTC Fire Security All rights reserved Edwards Signaling name and logo are trademarks of Fire Security trade names used in this document may be trademarks or trademarks of the manufacturers or vendors of the products A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL 34202 USA contact information see www edwardssignaling com 1 2 3 4 information iii overview and operation 1 overview 2 system requirements 3 overview 4 controls and indicators 5 module controls and indicators 8 and FSRA10C F controls and indicators 9 descriptions 10 the panel 11 17 checklist 18 the cabinet 19 remote modules 20 the F DACT F 21 an auxiliary booster power supply 22 programming 25 864 programming requirements 26 you begin 27 started 29 the panel 31 initiating device circuits 36 notification appliance circuits 40 coded alarm signals 43 programming 45 you begin 46 started 48 account options 50 dialer options 51 system event transmit options 53 IDC event transmit options 54 NAC event transmit options 55 system 4 2 event activation code options 56 IDC 4 2 event activation code options 57 NAC 4 2 event activation code options 58 dialer default settings 59 Series Technical Reference Manual 5 A B 61 maintenance 62 a walk test 63 lamp tests 65 messages 65 the control panel fuse 66 parts 67 calculations 69 calculation worksheet 70 appliance voltage drop calculation 73 appliance circuit calculations 74 templates 81 programming worksheet 82 programming worksheet 83 programming worksheet 85 programming worksheet 86 C Wiring diagrams 95 cautions and notes 96 D specifications 115 E event codes 117 Contact ID event codes 118 4 2 event codes 119 121 Series Technical Reference Manual information of liability the maximum extent permitted by applicable law in no event will UTCFS be for any lost profits or business opportunities loss of use business loss of data or any other indirect special incidental or damages under any theory of liability whether based in contract negligence product liability or otherwise Because some jurisdictions do not the exclusion or limitation of liability for consequential or incidental the preceding limitation may not apply to you In any event the total of UTCFS shall not exceed the purchase price of the product The limitation will apply to the maximum extent permitted by applicable law of whether UTCFS has been advised of the possibility of such and regardless of whether any remedy fails of its essential purpose in accordance with this manual applicable codes and the instructions the authority having jurisdiction is mandatory every precaution has been taken during the preparation of this manual to the accuracy of its contents UTCFS assumes no responsibility for errors omissions warning equipment can generate and radiate radio frequency energy If this is not installed in accordance with this manual it may cause to radio communications This equipment has been tested and found comply with the limits for Class A computing devices pursuant to Subpart B of 15 of the FCC Rules These rules are designed to provide reasonable against such interference when this equipment is operated in a environment Operation of this equipment is likely to cause in which case the user at his own expense will be required to take measures may be required to correct the interference FCC information ensure proper operation this dialer must be installed according to the installation instructions To verify that the dialer is operating properly can successfully report an alarm it must be tested immediately after Series Technical Reference Manual and periodically thereafter according to the enclosed test order for the dialer to be able to seize the phone line to report an alarm or event when other customer equipment telephone answering system modem etc connected to the same line is in use the dialer must be to a properly installed RJ 31X jack The RJ 31X jack must be in series with and ahead of all other equipment attached to the same line Series installation of an RJ 31X jack is depicted in the wiring If you have any questions concerning these instructions you should your telephone company or a qualified installer programming emergency numbers or making test calls to emergency remain on the line and briefly explain to the dispatcher the reason for call Perform programming and testing activities in the off peak hours such early morning or late evenings requirements equipment approved before July 23 2001 This dialer complies with Part of the FCC rules A label attached to the dialer contains among other the FCC registration number and ringer equivalence number REN this equipment If requested this information must be provided to the company equipment approved after July 23 2001 This dialer complies with Part 68 the FCC rules and the requirements adopted by the Administrative Council for Attachments ACTA A label attached to the dialer contains among information a product identifier in the format US AAAEQ TXXXX If this information must be provided to the telephone company plug and jack used to connect the dialer to the premises wiring and network must comply with the applicable FCC Part 68 rules and adopted by ACTA The dialer must be connected to a compliant or RJ 38X jack using a compliant cord If a modular telephone cord is with the dialer it is designed to meet these requirements See instructions for details ringer equivalence number REN is used to determine how many devices you connect to a telephone line If the total REN value for all devices connected a telephone line exceeds that allowed by the telephone company the devices not ring on an incoming call In most but not all areas the total REN value not exceed 5.0 To be certain of the total REN value allowed on a line contact the local telephone company Series Technical Reference Manual products approved after July 23 2001 the REN is part of the product in the format US AAAEQ TXXXX The digits represent the REN a decimal point Example 03 is an REN of 0.3 For earlier products the is listed separately the dialer is harming the telephone network the telephone company will notify in advance that temporary discontinuance of service may be required If notice isn practical the telephone company will notify you as soon as You will also be advised of your right to file a complaint with the FCC if believe it is necessary telephone company may make changes to its facilities equipment or procedures that could affect the operation of the dialer If this the telephone company will provide advance notice in order for you to necessary modifications to maintain uninterrupted service you are experiencing problems with the dialer contact Technical Support at for repair or warranty information If the dialer is harming the network the telephone company may request that you disconnect the until the problem is resolved dialer contains no user serviceable parts In case of defects return the dialer repair may not connect the dialer to a public coin phone or a party line service by the telephone company Canada information

Related Files