Edwards E-IDC2B Analog Dual Input Module Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Analog Dual Input Module Sheet module is an analog addressable device used to connect normally open alarm supervisory or monitor type dry initiating device circuits IDCs to a control panel This is designed for Class B circuit operation device address is set using the two rotary switches located the front of the module Two consecutive device addresses required The second device address is automatically one number higher that the value set on the rotary device can be preset for alarm or supervisory operation the slide switch located on the front of the module The can also be configured for other device types through panel programming or the configuration utility switch operation following slide switch settings determine the operation of module Setting the initial slide switch position is generally during module installation This setting can be while the system is operating but the change must be through front panel programming switch P1 is used for IDC 1 and slide switch P2 is used IDC 2 The waterflow device type available through front programming or the configuration utility can only be used slide switch P1 is closed a supervisory signal is sent the control panel and the supervisory is latched at the module Additional device types are available through front panel or the configuration utility Refer to applicable control technical reference manual 1 Slide switches operation module provides a bicolor LED that shows its status Green LED flashes Red LED flashes 1 Slide switch settings Operation used type description latching Configures the module for open dry contact initiating devices the NO input contact of an initiating is closed an alarm signal is sent to control panel and the alarm condition is at the module Factory default nonlatching US marketplace latching Canadian marketplace Configures the module for open dry contact initiating devices the NO input contact of an initiating is closed a supervisory signal is sent the control panel and the supervisory is not latched at the module Configures the module for open dry contact initiating devices the NO input contact of an initiating module will not operate without electrical power As frequently cause power interruption you should further safeguards with your local fire protection module does not support conventional smoke The module is shipped from the factory as an assembled it contains no user serviceable parts and should not be install the module Verify that all field wiring is free of opens shorts and faults Make all wiring connections shown in Set the module address as follows a screwdriver to adjust the two rotary switches on the of the module Set the TENS rotary switch 0 through for the 10s and 100s digit and the ONES rotary switch the 0 through 9 digit For example device address 21 2013 UTC Fire Security All rights reserved 4 3101193 REV 02 REB 28JAN13 3 Module installation TENS rotary switch to 2 and set the ONES rotary to 1 to for available address numbers Set slide switches P1 and P2 to appropriate setting Refer Mount the module on the electrical box using screws with the electrical box Mount the wall plate on the module using 4 24 x 1 2 in mm self tapping screws 2 Module address box plate in accordance with NFPA 72 and CAN ULC S524 Be to observe the polarity of the wires as shown in the 4 Module wiring next out out in in Maximum 25 resistance per wire Maximum 12 AWG 2.5 mm2 wire minimum 18 AWG 0.75 mm2 wire Refer to the control panel technical reference manual for wiring specifications Maximum 10 VDC at 350 All wiring is power limited and supervised This module will not support two wire smoke detectors B Class B 2 4 NO device 4 3101193 REV 02 REB 28JAN13 line voltage 20.6 V peak to peak k fault impedance environment temperature range electrical boxes size address to 120 F 0 to 49 C to 93 RH noncondensing at 90 F C to 140 F to 60 C American 4 inch square x in 64 mm deep 2 gang box 4 in square box 1 1 2 in mm deep 14 16 or 18 AWG wire 2.5 1.5 or 0.75 mm2 Sizes 16 and 18 are preferred to 63 64 point control panel to 126 127point control panel device circuit IDC resistor value circuit resistance circuit capacitance k P N EOL 47 25 per wire 3101193 REV 02 REB 28JAN13 4 4 3101193 REV 02 REB 28JAN13

Related Files