Edwards E-IDCWS Analog Dual Input Waterflow- Supervisory Module Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-e-idcws-analog-dual-input-waterflow-supervisory-module-installation-sheet-2164589703.pdf |
---|---|
Type | |
Size | 699.67 KB |
Downloads |
Text Preview
Analog Dual Input Waterflow Module Installation Sheet module is an analog addressable device used to connect open waterflow alarm and supervisory initiating circuits IDCs to a control panel This module is for Class B circuit operation device address is set using the two rotary switches located the front of the module Two consecutive device addresses required The second device address is automatically one number higher that the value set on the rotary module can operate in the following modes 1 Module operation type description latching delayed Configures the module for use only nonretarded waterflow alarm switches When NO input contact of an initiating device is closed an is sent to the control panel which after a 16 time delay generates an alarm signal Supervisory active nonlatching US marketplace active latching Canadian marketplace Configures the module for normally open contact initiating devices When the NO input of an initiating device is closed a supervisory is sent to the control panel and the supervisory is not latched at the module Configures the module for normally open dry initiating devices When the NO input contact of initiating device is closed a supervisory signal is to the control panel and the supervisory condition not latched at the module operation module provides a bicolor LED that shows its status Green LED flashes Red LED flashes module will not operate without electrical power As frequently cause power interruption you should further safeguards with your local fire protection module does not support conventional smoke The module is shipped from the factory as an assembled it contains no user serviceable parts and should not be install the module Verify that all field wiring is free of opens shorts and faults Make all wiring connections as shown in Set the module address as follows a screwdriver to adjust the two rotary switches on the of the module Set the TENS rotary switch 0 through for the 10s and 100s digit and the ONES rotary switch the 0 through 9 digit For example device address 21 TENS rotary switch to 2 and set the ONES rotary to 1 to for available address numbers Mount the module on the electrical box using screws with the electrical box Mount the wall plate on the module using 4 24 x 1 2 in mm self tapping screws 1 Module address 2013 UTC Fire Security All rights reserved 2 3101194 REV 02 REB 28JAN13 2 Module installation line voltage environment temperature range electrical boxes fault impedance k 20.6 V peak to peak to 120 F 0 to 49 C to 93 RH to 140 F to 60 C American 4 inch square x in 64 mm deep 2 gang box 4 in square box 1 1 2 in mm deep 14 16 or 18 AWG wire 2.5 1.5 or 0.75 mm2 Sizes 16 and 18 are preferred to 63 64 point control panel to 126 127 point control panel device circuit IDC resistor value circuit resistance circuit capacitance k P N EOL 47 25 per wire B Class B 2 4 NO Switch NO Switch box size address plate in accordance with NFPA 72 and CAN ULC S524 Be to observe the polarity of the wires as shown in the 3 Module wiring next out out in in Maximum 25 resistance per wire Maximum 12 AWG 2.5 mm2 wire minimum 18 AWG 0.75 mm2 wire Refer to the control panel technical reference manual for wiring specifications Maximum 10 VDC at 350 All wiring is power limited and supervised This module will not support two wire smoke detectors 2 3101194 REV 02 REB 28JAN13