Edwards E-NAC Analog NAC Module Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-e-nac-analog-nac-module-installation-sheet-2480671395.pdf |
---|---|
Type | |
Size | 712.11 KB |
Downloads |
Text Preview
Analog NAC Module Installation Sheet The module is shipped from the factory as an assembled it contains no user serviceable parts and should not be install the module Verify that all field wiring is free of opens shorts and faults Make all wiring connections as shown in Set the module address as follows a screwdriver to adjust the two rotary switches on the of the module Set the TENS rotary switch 0 through for the 10s and 100s digit and the ONES rotary switch the 0 through 9 digit For example device address 21 TENS rotary switch to 2 and set the ONES rotary to 1 to for available address numbers Mount the module on the electrical box using screws with the electrical box Mount the wall plate on the module using 4 24 x 1 2 in mm self tapping screws 1 Module address module is an analog addressable device used to connect supervised output circuit to a signal riser The output wiring is for open and short circuits A short circuit causes the to inhibit the activation of the audible visual signal so the riser is not connected to the wiring fault Upon from the control panel the module connects the circuit to the riser input The output circuit energizes a to operate polarized audible and visual signals The can be used for connection of a Class A or Class B EOL output notification appliance circuit NAC device address is set using the two rotary switches located the front of the module One device address is required module is configured to operate as a Genesis device type from the factory The can also be configured for other device types through panel programming or the configuration utility Refer to applicable control panel technical reference manual for a of available device types Audible Visual Silence Used with Genesis and Integrity horns and strobes Genesis and Enhanced appliances maintain synchronization per UL 1971 For devices this configuration allows connected horns to silenced while strobes on the same two wire circuit continue flash until the panel is reset You may use nonsynchronous fire alarm signals with or of compatible synchronized fire alarm signals but the of these devices will not comply with UL 1971 operation module provides a bicolor LED that shows its status Green LED flashes Red LED flashes module will not operate without electrical power As frequently cause power interruption you should further safeguards with your local fire protection module does not support conventional smoke 2013 UTC Fire Security All rights reserved 4 3101195 REV 02 REB 28JAN13 2 Module installation box plate 20.6 V peak to peak k to 120 F 0 to 49 C to 93 RH noncondensing at F 32 C VDC at 2 A max k P N EOL 47 to 140 F to 60 C American 4 inch square x in 64 mm deep 2 gang box 4 in square box 1 1 2 in mm deep 14 16 or 18 AWG wire 2.5 1.5 or 0.75 mm2 Sizes 16 and 18 are preferred to 64 64 point control panel to 127 127 point control panel line voltage fault impedance environment ratings current resistor value temperature range electrical boxes size address 4 in accordance with NFPA 72 and CAN ULC S524 Be to observe the polarity of the wires as shown in Figure 3 protection caution module requires transient protection for installations that electromechanical bells or horns to output circuits The circuitry requires a bipolar transient protector 235196P for protection against transient spikes caused the inductive load of bells or horns the bipolar transient protector assembly across the of the bell or horn electrically closest to the module bipolar transient protector is not polarity sensitive bells and horns at least 6 ft 1.83 m from the module 3101195 REV 02 REB 28JAN13 3 Module wiring VDC VDC next out out in in PWR IN 3 5 wired as above Z Class A 2 5 6 horn or strobe circuit 7 k EOLR for B only Y Class B 2 5 6 Z Class A 2 5 6 bell circuit Y Class B 2 5 6 k EOLR for B only Maximum 25 resistance per wire Maximum circuit capacitance of 0.1 Maximum 12 AWG 2.5 mm2 wire minimum 18 AWG 0.75 mm2 wire Refer to the control panel technical reference manual for wiring specifications the NAC power riser is used for more than one notification zone install in accordance with the survivability from attack by fire requirements NFPA 72 Supervised Polarity shown in alarm condition Polarity reverses on supervisory condition Typical synchronized temporal horn strobe circuit when configured as Class A B auto sync signal output module through programming Transient protection see protection caution 3101195 REV 02 REB 28JAN13 4 4 3101195 REV 02 REB 28JAN13