Edwards E-PHD Photoelectric and Fixed Temperature Heat Detector Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-e-phd-photoelectric-and-fixed-temperature-heat-detector-installation-sheet-4219870635.pdf |
---|---|
Type | |
Size | 657.38 KB |
Downloads |
Text Preview
Photoelectric and Fixed Temperature Detector Installation Sheet E PHD Photoelectric and Fixed Temperature Heat uses an optical sensing chamber to detect smoke and fixed temperature heat sensor to detect heat from fire The analyzes the sensor data to determine when to initiate alarm The detector continuously monitors changes in due to the environment e g dirt smoke humidity and notifies the control panel of its The heat sensor monitors the temperature of the air its surroundings and determines whether an alarm should be detector is capable of performing comprehensive self and storing the results The detector issues a dirty warning when it reaches its preset limit This notifies operator of the need for service while the detector is still operation detector provides a bicolor LED that shows its status Normal Green LED flashes Red LED flashes to Edwards Signaling Smoke and Heat Detectors Bulletin P N 3101212 for additional information detector placement and spacing detector does not operate without electrical power As frequently cause power interruption discuss further with the local fire protection specialist detector does not sense fires in areas where smoke reach the detector Smoke from fires in walls or on the opposite side of closed doors may not the detector detectors have a wide range of sensing but are best suited for detecting slow fires ensure proper operation schedule maintenance or selected in accordance with the requirements the authority having jurisdiction Refer to NFPA 72 and ensure proper operation store the detector within the ranges Allow the detector to stabilize to temperature before applying power the dust cover supplied on the detector during and remove it prior to commissioning and The dust cover is not a substitute for removing the during new construction or heavy remodeling install the detector and wire the detector base using the installation supplied with the detector base Set the detector address Refer to the panel technical manual for a list of valid addresses Use a to adjust the two rotary switches on the back the detector Set the left rotary switch 0 through 12 for 10s and 100s digit and the right rotary switch for the 0 9 digit Connect the detector to the base by rotating the detector until it snaps into the locked position head can be removed by turning it counterclockwise the head must lock to the base break away the locking using a pair of pliers then remove the detector head after breaking away the tab insert a small screwdriver into the slot on the of the base and press in while simultaneously turning detector head counterclockwise 1 Setting detector address address 32 shown 6 5 9 screwdriver here 2013 UTC Fire Security All rights reserved 4 3101208 REV 03 REB 28JAN13 2 Breakaway tab 3 Detector disassembly 6 4 5 9 block to insert r e Breakaway tab the detector cleaning is necessary the sensing chamber of the unsnaps for easy field cleaning and service Only the smoke element of the detector requires clean the detector Remove the detector from the base a screwdriver in the small slot where the detector connects to the detector body Pry the detector cap off the detector body Squeeze the optical block chamber where the two arrows labeled here Pull off the optical block chamber Blow off the optical block base in the detector body using compressed air Snap a new optical block chamber in place Make sure line up the two arrows on the block chamber with the on the optical block base Connect the detector cap to the detector body by rotating cap clockwise until it snaps into a locked position the detector onto the base To verify the effectiveness of the cleaning the device and run a device maintenance Refer to the control panel technical reference Test the detector and verify sensitivity body block base cap Slot to insert screwdriver Optical block chamber Detector body Optical block base Detector cap 72 and CAN ULC code require calibrated test upon completion of the original installation and any modifications or additions to the system The can perform this test and generate a system report Test both the smoke element and the heat element of detector test the detector Before initial testing remove the dust cover from the and notify the proper authorities that the fire system is undergoing maintenance and will be out of service Test the detector smoke element using Smoke In A Can SM 200 canned smoke Carefully follow on the can to avoid damage to the detector Test the detector heat element using a heat gun a six inch minimum distance Use caution as heat can damage the detector and detector 4 3101208 REV 03 REB 28JAN13 line voltage operating current current sensitivity range fixed temp alarm rating compensation bases distance from ceiling temperature environment 20 V peak to peak to 3.66 ft obscuration to 3.70 ft obscuration 57 B4U B4U LP RB4U IB4U SB4U in 305 mm to 140 F to 60 C to 120 F 0 to 49 C to 93 RH noncondensing at F 32 C and compliance 1 A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the date code located the product identification label are the of manufacture UL 268 ULC S529 02 UL 521 S530 M91 NFPA 72 and CAN ULC S524 of manufacture American For warranty and return see information below information contact information see our Web site 3101208 REV 03 REB 28JAN13 4 4 3101208 REV 03 REB 28JAN13