Edwards E-RLY Analog Contact Relay Module Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Analog Contact Relay Module Sheet E RLY Analog Contact Relay Module is an analog device that provides one Form C dry relay It can also be configured to provide polarity reversal of output The module can be used to control external or shut down equipment device address is set using the two rotary switches located the front of the module One device address is required module is wired according to its operation as shown in on page 2 The module is configured to operate as a nonsilence device type from the factory It can function as a control relay or polarity reversal relay depending on it is wired relay function Addressable device that provides one C dry relay contact The system firmware ensures that relay is in the proper state when powered up Upon from the control panel the E RLY relay energizes reversal relay function Addressable device that polarity reversal of its output The system firmware that the relay is in the proper state when powered up command from the control panel the E RLY relay reversing the polarity of its output Additional device types are available through front panel or the configuration utility Refer to the applicable panel technical reference manual operation module provides a bicolor LED that shows its status Green LED flashes Red LED flashes Connecting a device that exceeds this module duty contact ratings may cause activation failure This does not support capacitive loads See page 4 for contact ratings module is shipped from the factory as an assembled it contains no user serviceable parts and should not disassembled module will not operate without electrical power As frequently cause power interruption you should further safeguards with your local fire protection module does not support conventional smoke the module within the same room as the device it is install the module Verify that all field wiring is free of opens shorts and faults Wire the module in accordance with on page 2 Set the module address as follows a screwdriver to adjust the two rotary switches on the of the module Set the TENS rotary switch 0 through for the 10s and 100s digit and the ONES rotary switch the 0 through 9 digit For example device address 21 the TENS rotary switch to 2 and set the ONES rotary to 1 to on page 4 for available address Mount the module on the electrical box using screws with the electrical box See Figure 2 Mount the wall plate on the module using 4 24 x self tapping screws 2013 UTC Fire Security All rights reserved 4 3101196 REV 02 ISS 28JAN13 1 Module address Address switches 2 Module installation Only one conductor per terminal signaling line circuit SLC circuit is power limited and Refer to the panel documentation for SLC wiring wire the module Verify that all field wiring is free of opens shorts and faults Make all wiring connections using Figure 3 or Figure 4 to the desired function Observe polarity of the as shown in the diagrams 4 24 1 2 self tapping screw Wall plate Screw Module Compatible electrical box in accordance with applicable requirements of the latest of the local codes and standards and the local having jurisdiction When stripping wire ends exposing more wire may a ground fault exposing less wire may result in a faulty 1 4 in about 6 mm from the ends of all wires that to the terminal block of the module 4 3101196 REV 02 ISS 28JAN13 3 Control relay function Normally closed contact NC Normally open contact NO Common contact Power limited unless connected to a nonpower limited source If source is nonpower limited eliminate the power limited mark maintain a minimum of 0.25 in 6.4 mm space from power wiring For other mounting methods see enclosure and installation sheets to maintain separation of power and nonpower limited wiring The wire size must be of handling fault current from nonpower limited source or 4 Polarity reversal relay function type FPL FPLR FPLP or permitted substitute cables these power limited cable conductors extending beyond jacket are separated by a minimum of 0.25 in 6.4 mm or by a nonconductive sleeve or nonconductive barrier all other conductors Refer to the NFPA 70 National Code for more details All wiring is power limited and supervised Signaling line circuit SLC from previous device Signaling line circuit SLC to next device Not used Normal Active Power out Power in Power limited unless connected to a nonpower limited source If source is nonpower limited eliminate the power limited mark maintain a minimum of 0.25 in 6.4 mm space from power wiring For other mounting methods see enclosure and installation sheets to maintain separation of power and nonpower limited wiring The wire size must be of handling fault current from nonpower limited source or type FPL FPLR FPLP or permitted substitute cables these power limited cable conductors extending beyond jacket are separated by a minimum of 0.25 in 6.4 mm or by a nonconductive sleeve or nonconductive barrier all other conductors Refer to the NFPA 70 National Code for more details All wiring is power limited and supervised Signaling line circuit SLC from previous device Signaling line circuit SLC to next device 3101196 REV 02 ISS 28JAN13 4 line voltage Maximum 20.6 V peak to peak information ratings pilot duty VDC VAC type fault impedance electrical boxes k A A resistive load 60 W or 62.5 VA C programmable of American compliance A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture UL 864 device complies with part 15 of the FCC Operation is subject to the following two 1 This device may not cause interference and 2 this device must any interference received including that may cause undesired operation information contact information see www edwardssignaling com inch square 2 1 2 in 64 mm single gang box inch square 2 1 2 in 64 mm double gang box 4 in square in 38 mm deep box 14 16 or 18 AWG wire 2.5 1.0 or 0.75 mm2 Sizes 16 18 AWG are preferred to 120 0 to 49 to 93 noncondensing to 140 to 60 to 64 64 point control panel to 127 127 point control panel size environment humidity temperature range address 4 3101196 REV 02 ISS 28JAN13

Related Files