Edwards EBPS Remote Booster Power Supply Technical Reference Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-ebps-remote-booster-power-supply-technical-reference-manual-6802194537.pdf |
---|---|
Type | |
Size | 1.00 MB |
Downloads |
Text Preview
Booster Power Technical Manual 3100485 EN REV 04 ISS 28AUG12 and 2012 UTC Fire Security All rights reserved Remote Booster Power Supply name and logo are trademarks UTC Fire Security trade names used in this document may be trademarks or trademarks of the manufacturers or vendors of the products A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL 34202 USA compliance A This equipment has been tested and found to comply with limits for a Class A digital device pursuant to part 15 of the FCC These limits are designed to provide reasonable protection harmful interference when the equipment is operated in a environment This equipment generates uses and can radio frequency energy and if not installed and used in with the instruction manual may cause harmful to radio communications Operation of this equipment in residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own Fire Department Certificate of Approval MEA 476 91 E XIII R TTE directive Hereby UTC Fire Security that this device is in compliance with the essential and other relevant provisions of Directive 1999 5 EC WEEE directive Products marked with this symbol be disposed of as unsorted municipal waste in the European For proper recycling return this product to your local supplier the purchase of equivalent new equipment or dispose of it at collection points For more information see battery directive This product contains a battery that be disposed of as unsorted municipal waste in the European See the product documentation for specific battery The battery is marked with this symbol which may lettering to indicate cadmium Cd lead Pb or mercury For proper recycling return the battery to your supplier or to a collection point For more information see contact information see www utcfireandsecurity com Union information information iii of liability iii Booster Power Supply FCC compliance iv 1 covered 1 1 procedure checklist 2 started 3 3 descriptions 4 5 indicators 6 the enclosure 7 option modules in the enclosure 8 the circuit board in the enclosure 10 the jumpers 12 Class A or Class B JP1 and JP2 12 fault enable JP3 12 charging JP4 13 864 programming requirements 14 the DIP switches 15 1 and 2 operation SW1 1 to 3 15 control SW1 4 16 circuit operation SW1 5 to 8 and SW2 1 to 4 17 mode for continuous NACs SW2 5 19 power loss reporting SW2 6 19 control during AC power loss SW2 7 19 A or B NAC configuration SW2 8 20 Booster Power Supply Technical Reference Manual routing 21 the field wiring 22 power wiring 22 wiring 22 Class B wiring 24 Class A wiring 25 circuit wiring 26 power wiring 26 trouble relay wiring 27 wiring using CC1 S modules 29 the 3 TAMP tamper switch 34 calculation worksheet 35 appliance circuit calculations 37 37 you need 37 method 39 method 40 BPS synchronization 43 of booster power supplies 43 of visible outputs 44 of visible and audible outputs 44 46 46 circuit notification 47 visible and audible circuit notification 48 visible and audible circuit to Genesis notification 49 audible or visible circuit to Genesis notification 50 visible circuit and conventional audible circuit to Genesis 51 split mode circuit with fault tolerance notification 52 split mode circuit with fault tolerance notification 53 Coder to Genesis notification 54 Coder to conventional notification 55 Coder to Genesis visibles and conventional audibles 56 control power supply 57 Booster Power Supply Technical Reference Manual information of liability the maximum extent permitted by applicable law in no event will UTCFS be for any lost profits or business opportunities loss of use business loss of data or any other indirect special incidental or damages under any theory of liability whether based in contract negligence product liability or otherwise Because some jurisdictions do not the exclusion or limitation of liability for consequential or incidental the preceding limitation may not apply to you In any event the total of UTCFS shall not exceed the purchase price of the product The limitation will apply to the maximum extent permitted by applicable law of whether UTCFS has been advised of the possibility of such and regardless of whether any remedy fails of its essential purpose in accordance with this manual applicable codes and the instructions the authority having jurisdiction is mandatory every precaution has been taken during the preparation of this manual to the accuracy of its contents UTCFS assumes no responsibility for errors omissions messages messages alert you to conditions or practices that can cause unwanted The advisory messages used in this document are shown and described Warning messages advise you of hazards that could result in injury loss of life They tell you which actions to take or to avoid in order to prevent injury or loss of life Caution messages advise you of possible equipment damage They tell which actions to take or to avoid in order to prevent the damage Note messages advise you of the possible loss of time or effort They how to avoid the loss Notes are also used to point out important that you should read Booster Power Supply Technical Reference Manual Booster Power Supply FCC compliance equipment can generate and radiate radio frequency energy If the is not installed in accordance with this manual it may cause to radio communications This equipment has been tested and found comply with the limits for Class A computing devices pursuant to Subpart B of 15 of the FCC Rules These rules are designed to provide reasonable against such interference when this equipment is operated in a environment Operation of this equipment is likely to cause in which case the user at his own expense will be required to take measures may be required to correct the interference Booster Power Supply Technical Reference Manual installation manual is intended for use by installers and field technicians It the installation procedures wiring diagrams DIP switch settings etc to install and set up the Remote Booster Power Supply BPS covered following table lists the booster power supply models that are covered in this number A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply A booster power supply input circuits of the booster power supply can be connected to 12 VDC or VDC systems details about device compatibility refer to the Remote Booster Power Supply