Edwards FSRZI-A(-SA) Remote Zone Indicators Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Remote Zone Indicators Sheet 2 Zone selection jumpers used to indicate zones 1 to 5 1 to IDC 5 on the control panel used to indicate zones 6 to 10 6 to IDC 10 on the control panel used Install a jumper on J3 only when connected to a 10 zone control Make sure all power is disconnected from the panel installing Observe static sensitive handling practices more information refer to the technical reference manual inside the control panel door install the remote zone indicator Configure the jumpers as described in Table 1 and Verify that all field wiring is free of opens shorts and 2 faults Wire the remote zone indicator as shown Figure 1 Mount the remote zone indicator in the electrical box using two plain machine screws See Figure 2 If you are surface mounting the remote zone you must install washers provided between it the surface mount box Attach the faceplate to the remote zone indicator Use the white machine screws provided with the faceplate Remote zone indicators will not operate properly until by the control panel For more information see the reference manual listed inside the control panel door FSRZI A and FSRZI SA are remote zone indicators for fire alarm control panels The FSRZI A provides five LEDs for indicating alarm zones The FSRZI SA provides bi color LEDs red for alarm zones yellow for supervisory monitor zones Configuration jumpers determine which are indicated and FSRZI SA remote zone indicators include a plate for installation in a standard single gang electrical You can install one or two FSRZI A and FSRZI SA remote indicators with or without an FSRSI remote system in an approved 2 3 or 4 gang electrical box Cover for 2 3 and 4 gang electrical boxes model numbers FSAT3 and FSAT4 are ordered separately paper insert is provided for creating custom LED labels and FSRZI SA remote zone indicators are configured the jumpers described in the tables below peripheral group 1 peripheral group 2 1 Group selection jumper Only two remote zone indicators are allowed per peripheral 2013 UTC Fire Security All rights reserved 2 3101032 REV 02 REB 25JAN13 1 Wiring diagram panel 24 VDC control panel or power supply 3 remote capacitance resistance fault impedance size electrical box humidity environment to 27.3 Vdc mA at 24 VDC mA at 24 VDC max ohms max ohms to 18 AWG 0.75 to 2.5 sq mm OS1 1996 1 to 4 gang box to 120 0 to 49 to 93 noncondensing All wiring is supervised and power limited AUX power supplied by the control panel can exceed 0.5 A If than 0.5 A is required you must use a power limited and 24 VDC auxiliary booster power supply that is UL ULC for fire protective signaling systems powered from an external supply the supply must be installed the same room as the control panel and their 24 VDC wired together 2 Installing the remote zone indicator in a single gang box 1 gang electrical box 2 3101032 REV 02 REB 25JAN13

Related Files