Edwards Gen Chime Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name edwards-gen-chime-installation-instructions-1920845637.pdf
Type PDF
Size 659.20 KB
Downloads

Text Preview

information Genesis Chime is an audible fire alarm notification designed for indoor walls See Table 1 for a list of numbers chime includes field configurable jumper options for the desired dB output steady or temporal chime and constant non coded voltage or single stroke coded operation A Genesis Signal Master is required when are configured for coded operation See Table 2 for a of compatible synchronization modules this device in accordance with applicable requirements the latest editions of the NFPA codes and standards and in with the local authorities having jurisdiction 1 Model numbers description with FIRE marking with FIRE marking plate numbers Chime 1 Model numbers description plate numbers 2 Compatible synchronization modules names Output Master piggyback numbers SIGA MCC1S LG Master Remote Synchronization module requirements are determined by application voltage 16 to 33 Vdc 16 to 33 Vfwr device was tested to the regulated 24 Vdc fwr voltage limits of 16 V and 33 V Do not apply and 110 of these values for system operation current See Table 2 level output See Table 3 60 strokes per minute 3 stroke pattern Maximum 60 strokes per minute modes Continuous voltage Single stroke controlled by voltage settings Steady level output High db Non coded size 12 to 18 AWG 2.50 to 0.75 sq mm electrical boxes American 2 1 2 in 64 mm deep 1 gang box 4 in square box 1 1 2 in 38 mm 2 gang or 4 in with G1T or G1RT trim accessory temperature range 32 to 120 0 to 49 humidity range 0 to 93 RH listings Meets or exceeds UL464 Seventh Edition for mode Sheet Chime P N 3100561 REV 1.0 2 2 Operating current in Amp RMS db Vdc Vdc Vdc Vfwr Vfwr Vfwr Volts direct current regulated and filtered Volts full wave rectified db 3 Sound level output dBA and voltage db Vdc Vdc Vdc Vdc Vdc Vdc db Decibels A weighted Sound level output at 10 ft 3.05 m measured in a room instructions Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals install the chime Remove the cover by depressing both tabs on the top of unit with a small screwdriver and twisting slightly Set the chime signal sound output level and desired settings See Figure 1 Connect the chime terminals to the signal circuit field You must observe polarity for the unit to function constant non coded voltage operation see Figure 2 single stroke coded voltage operation see Figure 3 Mount the unit onto a compatible electrical box making not to over tighten the mounting screws Replace the cover by aligning at the bottom then in at the top Test the unit for proper operation unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction change the chime steady to temporal cut circle J1 to edge of board change the chime level high dB to dB cut J3 trace between J3 change the chime non coded to coded single from circle J2 to edge circuit board next device or of line device 1 Chime settings compatible fire control panel Polarity shown in alarm condition 2 Constant non coded voltage operation device with Signal Master next device or of line device source power 2 3100561 REV 1.0 3 Single stroke coded voltage operation

Related Files