Edwards Genesis Ceiling Horn-Strobe Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-genesis-ceiling-horn-strobe-installation-sheet-8307596124.pdf |
---|---|
Type | |
Size | 938.66 KB |
Downloads |
Text Preview
Ceiling Horn Strobe Installation Sheet Genesis Ceiling Horn Strobe is a fire alarm notification designed for indoor ceilings and walls See Table 1 a list of model numbers 1 Models to 95 multi cd white MGC HDVM MGCF HDVM to 95 multi cd white with marking to 95 multi cd red with marking configurable jumper options are available for selecting desired dB output temporal or steady horn output and signal output horn strobe includes a field configurable switch for the desired candela output The candela output is locked in place and remains visible after final strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Signaling for the Hearing Impaired and the latest Canadian CAN ULC S526 Synchronized operation requires a installed synchronization control module See 2 for a list of compatible synchronization modules this device in accordance with applicable requirements the latest editions of the NFPA codes and standards and Electrical Code Part 1 Section 32 and CAN ULC Standard for the Installation of Fire Alarm Systems and accordance with the local authorities having jurisdiction 2 Compatible synchronization module models output module signal master mount To reduce the risk of shock disconnect all power allow 10 minutes for stored energy to dissipate before Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals install the horn strobe Remove the cover by depressing the tab on the side of the with a small screwdriver Turn the cover to release Set the horn signal sound output level and strobe signal the desired settings See Figure 2 Connect the strobe terminals to the signal circuit field You must observe polarity for the unit to function See Figure 4 Slide the candela switch to the desired candela output 95 150 or 177 cd by aligning it with the indicator below switch See Figure 1 Mount the unit onto a compatible electrical box See 5 Replace the cover by positioning the alignment arrows and rotating the cover clockwise Test the unit for proper operation 1 Candela switch Candela switch 2013 UTC Fire Security All rights reserved 4 3100616 REV 05 REB 30JAN13 2 Horn and strobe settings Horn signal jumper Cut to change from temporal to steady Strobe signal output Cut to change from 1 flash per second mode to temporal private mode Horn sound output Cut to change from high dB to low dB If the strobe is set to temporal private mode this device no longer UL 1971 or ULC S526 Listed or FM Approved but UL 1638 Listed 3 UL 1971 minimum light output of rating vs angle 10 15 20 Angle Percentage of rated output Horizontal and vertical outputs have the same pattern 4 Wiring Diagram From NAC output To next NAC output Signal polarity is shown in the alarm condition 5 Mounting diagram 3 Strobe operating current in RMS A cd cd cd cd Volts direct current regulated and filtered Volts full wave rectified currents shown above were measured by UL at 16 VDC and VFWR 4 3100616 REV 05 REB 30JAN13 4 Sound level output dBA db db Sound level output at 10 ft 3.05 m measured in a reverberant 5 Minimum sound level output per ULC S525 dBA peak db 24 VDC 24 VFWR 96 24 VDC 24 VFWR 96 db Meets or exceeds 85 dBA in an anechoic chamber at 10 ft m 6 Audible directional characteristics horizontal pattern 1 Ref and 115 and 120 output dBA 2 Ref Angles are measured from a perpendicular axis positive angles to right Peak output at regulated 24 VDC set for temporal tone 7 Audible directional characteristics vertical pattern 1 Ref and 135 and 140 output dBA 2 Ref Angles are measured from a perpendicular axis positive angles are Peak output at regulated 24 VDC set for temporal tone 6 Light output profile 350 355 unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction no change the factory applied finish 3100616 REV 05 REB 30JAN13 4 level operating output level output settings size electrical environment humidity signal 24 VDC 24 VFWR Table 3 at 15 30 75 and 95 cd Table 4 dB flash per second fps to 18 AWG 0.75 TO 2.50 mm American 4 in square electrical box in deep no extension ring to 120 0 to 49 to 93 noncondensing information A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture 24 DC and 24 FWR device was tested to the regulated DC FWR operating voltage limits of 16 V and V Do not apply 80 and 110 of these for system operation Indoor UL 1971 requirements Maximum allowed between any two devices is 20 to specifications for the synchronization module this strobe and the control panel determine allowed wire resistance ULC S525 ULC S526 464 UL 1638 and UL 1971 of rating listings information contact information see www edwardsutcfs com 4 3100616 REV 05 REB 30JAN13