Edwards Genesis Chime-Strobe Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-genesis-chime-strobe-installation-sheet-5973280164.pdf |
---|---|
Type | |
Size | 787.41 KB |
Downloads |
Text Preview
Genesis Chime Strobe Installation Sheet are field configurable options for selecting dB output signal and constant noncoded voltage or single stroke voltage operation See Figure 1 A Genesis Signal Master is required when chimes are for coded operation strobe includes a field configurable switch for selecting the candela output The candela output setting is locked in and remains visible after final installation strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Signaling for the Hearing Impaired Synchronized operation a separately installed synchronization control module Table 2 for a list of compatible synchronization modules MG1M RM 2 Compatible synchronization module models 1 Signal Master Mount Signal Master Mount Output Module SIGA CC1S SIGA MCC1S Input Signal Module Power Supply Supply SIGA MCC2 A Synchronization module requirements are determined by the this device in accordance with applicable requirements the latest editions of the NFPA codes and standards and in with the local authorities having jurisdiction Electrocution hazard To avoid personal injury or from electrocution remove all sources of power and stored energy to discharge before installing or removing Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals install the chime strobe Remove the cover by depressing both tabs on the top of unit with a small screwdriver and twisting slightly Genesis Chime Strobe is a fire alarm notification designed for indoor ceilings and walls See Table 1 a list of model numbers 1 Models 15 to 110 multi white 15 to 110 multi white with FIRE marking 15 to 110 multi red 15 to 110 multi red with FIRE marking plate white plate red 2010 UTC Fire Security All rights reserved 4 3100562 REV 2.0 ISS 19AUG10 Set the chime signal sound output level and desired settings See Figure 1 change the chime signal from steady to temporal from circle J1 to the edge of the circuit board change the chime operation from noncoded to single stroke cut from circle J2 to the edge of circuit board change the chime sound output level from high dB low dB cut the J3 trace between the holes Slide the candela switch to the desired candela output by it with the indicator located beside the switch See 2 Connect the chime terminals to the signal circuit field For the unit to function properly observe polarity Figure 1 single stroke coded voltage operation see 3 constant noncoded voltage operation see 4 Mount the unit onto a compatible electrical box making not to overtighten the mounting screws Replace the cover by aligning it at the bottom then it in at the top Test the unit for proper operation 1 Chime settings 3 Wiring for single stroke coded voltage operation Chime in coded power signal Strobe in continuous power signal Resistor value determined by the control panel Genesis Signal Master To next appliance EOL resistor or Class A circuit return One wire each side of screw head shown in alarm condition strobe circuit can be silenced without turning off strobes 4 Wiring for constant noncoded voltage operation J3 Chime signal jumper Coded non coded jumper Chime sound output 2 Candela switch From NAC output To next appliance EOL or Class A return Signal polarity is shown in the alarm condition unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction no change the factory applied finish 4 3100562 REV 2.0 ISS 19AUG10 5 UL 1971 minimum light output of rating vs angle 10 15 20 Angle Minimum UL required candela light output of rated candela vertical specification of rated candela horizontal specification level operating output level output settings modes size electrical environment humidity VDC or 24 VFWR nominal Table 3 at 15 30 75 and 110 cd Table 4 dB strokes per minute pattern 60 strokes per minute voltage controlled by voltage to 18 AWG 0.75 TO 2.50 mm in 64 mm deep single gang box in square box 1 1 2 in 38 mm 2 gang in octagonal with G1T or G1RT trim to 120 0 to 49 to 93 noncondensing 3 Strobe operating current in RMS A cd cd cd cd Volts direct current regulated and filtered Volts full wave rectified currents shown above were measured by UL at 16 VDC and VFWR 4 ULI Ratings temporal output private mode db db Decibels A weighted Sound level output at 10 ft 3.05 m measured in a reverberant at 16 V information A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture 24 DC and 24 FWR Indoor UL 1971 requirements Maximum allowed between any two devices is 20 to specifications for the synchronization module this strobe and the control panel determine allowed wire resistance UL1638 UL1971 see Figure 1 and private mode of rating listings information contact information see www utcfireandsecurity com 3100562 REV 2.0 ISS 19AUG10 4 4 3100562 REV 2.0 ISS 19AUG10