Edwards Genesis High Candela Ceiling Speaker-Strobe Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-genesis-high-candela-ceiling-speaker-strobe-installation-sheet-2317468590.pdf |
---|---|
Type | |
Size | 1.17 MB |
Downloads |
Text Preview
High Candela Ceiling Speaker Strobe Sheet Genesis High Candela Ceiling Speaker Strobe is a fire notification appliance designed for indoor ceilings and See Table 1 for a list of model numbers MGC S2VMH MGCF S2VMH MGC S7VMH MGCF S7VMH 1 Models VRMS 95 to 177 multi cd VRMS 95 to 177 multi cd with FIRE marking VRMS 95 to 177 multi cd VRMS 95 to 177 multi cd with FIRE marking field configurable jumper option is available for selecting the strobe signal output speaker strobe includes field configurable switches for the desired candela and wattage outputs These settings lock in place and remain visible after final strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Signaling for the Hearing Impaired and the latest Canadian CAN ULC S526 Synchronized operation requires a installed synchronization control module See 2 for a list of compatible synchronization modules this device in accordance with applicable requirements the latest editions of the NFPA codes and standards and Electrical Code Part 1 Section 32 and Standard for the Installation of Fire Alarm and in accordance with the local authorities having 2 Compatible synchronization module models name Output Module SIGA MCC1S GSA MCC1S MG1M RM Signal Master Mount To reduce the risk of shock disconnect all power allow 10 minutes for stored energy to dissipate before Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals When installed these devices are not centered on the box Make sure boxes are mounted to compensate this difference See Figure 7 install the speaker strobe Open the cover by depressing the tab on the side of the with a small screwdriver Hinge the cover down to the mounting screws and selectable candela and switches The cover is also detachable for convenience temporal strobe private mode operation is desired cut JP1 See Figure 2 Connect the speaker and strobe terminals to the signal field wiring For the unit to function properly polarity See Figure 4 Slide the candela switch to the desired candela output 95 150 or 177 cd by aligning it with the indicator below switch See Figure 1 Slide the wattage switch to the desired wattage tap 2 W W 1 2 W or 1 4 W by aligning it with the indicator the switch See Figure 1 Mount the unit onto a compatible electrical box See 5 2013 UTC Fire Security All rights reserved 4 3100615 REV 05 REB 30JAN13 Replace the cover by positioning the alignment arrows and rotating the cover clockwise 4 Wiring diagram Test the unit for proper operation 1 Field selectable switches Wattage switch Candela switch 2 Strobe settings From NAC output To next NAC output Amplifier output voltage matching the voltage ratings of the 25 or 70 VRMS Signal polarity is shown in the alarm condition 5 Mounting diagram Strobe signal output Cut to change from 1 flash per second mode to temporal private mode If the strobe is set to temporal private mode this is no longer UL 1971 or ULC S526 Listed or FM but is UL 1638 Listed 3 UL 1971 minimum light output of rating vs angle 10 15 20 Angle Percentage of rated output Horizontal and vertical outputs have the same pattern 4 3100615 REV 05 REB 30JAN13 3 Strobe operating current in RMS A cd cd cd cd Volts direct current regulated and filtered Volts full wave rectified currents shown above were measured by UL at 16 VDC and VFWR 4 Sound level output dBA W W W W UL W ULC UL ULC UL ULC Sound level output at 10 ft 3.05 m measured in a room using 400 to 4,000 Hz band limited pink noise characteristics Within 6 dB of on axis sound level when 90 off axis horizontal 6 Light output profile a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction no change the factory applied finish voltage voltage operating level output response output settings size electrical environment humidity VRMS model S2 or 70 VRMS model S7 VDC 24 VFWR V maximum Table 3 Table 4 to 4,000 Hz at 95 115 150 and 177 cd flash per second fps to 18 AWG 0.75 TO 2.50 mm American 4 in square electrical box in min deep to 120 0 to 49 to 93 noncondensing information A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture 24 DC regulated 24 FWR device was tested to the regulated DC FWR operating voltage limits of 16 V and V Do not apply 80 and 110 of these for system operation Indoor dry UL 1971 requirements Maximum allowed between any two devices is 20 to specifications for the synchronization module this strobe and the control panel determine allowed wire resistance 1480 UL 1638 and UL 1971 ULC S541 ULC S526 EN 60065 2002 1 of rating listings Nameplate marking is located on the inside surface of the device information contact information see www edwardsutcfs com unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement 3100615 REV 05 REB 30JAN13 4 7 Mounting template Speaker Strobe Center of ceiling tile or speaker strobe Cut line for location of electrical box Electrical box template center the speaker strobe Position the template to the center of the ceiling tile Orient the strobe to the desired visual position Mark the location for the electrical box 4 3100615 REV 05 REB 30JAN13