Edwards Genesis High Candela Ceiling Strobe Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

High Candela Ceiling Strobe Installation Genesis High Candela Ceiling Strobe is a fire alarm appliance designed for indoor ceilings and walls Table 1 for a list of model numbers 1 Models to 177 multi cd to 177 multi cd with FIRE field configurable jumper option is available for selecting the strobe signal output strobe includes a field configurable switch for selecting the candela output The candela output setting is locked in and remains visible after final installation strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Signaling for the Hearing Impaired and the latest Canadian CAN ULC S526 Synchronized operation requires a installed synchronization control module See 2 for a list of compatible synchronization modules 2 Compatible synchronization module models Output Module Master Remote and backup power To reduce the risk of shock disconnect all power allow 10 minutes for stored energy to dissipate before Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals this device in accordance with applicable requirements the latest editions of NFPA 72 National Fire Alarm and Code and the CAN ULC S524 Standard for the of Fire Alarm Systems and in accordance with the authorities having jurisdiction install the strobe Remove the cover by depressing the tab on the side of the with a small screwdriver Turn the cover to release Set the strobe signal to the desired settings See Figure 2 Connect the strobe terminals to the signal circuit field You must observe polarity for the unit to function See Figure 4 Slide the candela switch to the desired candela output 95 150 or 177 cd by aligning it with the indicator below switch See Figure 1 Mount the unit onto a compatible electrical box See 5 Replace the cover by positioning the alignment arrows and rotating the cover clockwise Test the unit for proper operation 1 Candela switch 2013 UTC Fire Security All rights reserved 4 3100613 REV 05 REB 30JAN13 Candela switch 2 Strobe settings 4 Wiring diagram From previous device or control panel To next device EOL or circuit return Signal polarity is shown in the alarm condition 5 Mounting diagram Strobe signal output Cut to change from 1 flash per second mode to temporal private mode If the strobe is set to temporal private mode this is no longer UL 1971 or CAN ULC S526 Listed or FM but is UL 1638 Listed 3 UL 1971 minimum light output of rating vs angle 10 15 20 Angle Percentage of rated output Horizontal and vertical outputs have the same pattern For proper supervision of fire alarm circuitry break at S and S See Figure 4 3 Strobe operating current in RMS A cd cd cd cd Volts direct current regulated and filtered Volts full wave rectified currents shown above were measured by UL at 16 VDC and VFWR 4 3100613 REV 05 REB 30JAN13 6 Light output profile 350 355 plane Plane ULC requirement cd Do not change factory applied finishes unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction voltage operating output level output settings size electrical environment humidity to 33 VDC and 16 to 33 VFWR Table 3 at 95 115 150 and 177 cd Table 4 flash per second fps to 18 AWG 0.75 to 2.50 mm American 4 in square electrical box in deep no extension ring to 120 0 to 49 to 93 noncondensing information A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture 24 DC regulated 24 FWR device was tested to the regulated DC FWR operating voltage limits of 16 V and V Do not apply 80 and 110 of these for system operation Indoor UL 1971 requirements Maximum allowed between any two devices is 20 to specifications for the synchronization module this strobe and the control panel determine allowed wire resistance 1638 and UL 1971 S 526 of rating listings information contact information see www edwardsutcfs com 3100613 REV 05 REB 30JAN13 4 4 3100613 REV 05 REB 30JAN13

Related Files