Edwards Genesis Remote Mount Signal Master Module Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-genesis-remote-mount-signal-master-module-installation-sheet-9302417685.pdf |
---|---|
Type | |
Size | 767.45 KB |
Downloads |
Text Preview
Remote Mount Signal Master Module Sheet Genesis Remote Mount Signal Master Module provides synchronization and independent horn control for strobes and horns Model numbers are listed below install the module Verify that all field wiring is free of opens shorts and Make all wiring connections as shown in Figure 2 through faults 4 1 Models Remote Mount Master Module 1 Using the 4 24 x 1 2 in screw mount the wall plate on the as shown in Figure 1 Using the two 6 32 x 1 2 machine screws mount the in the electrical box 1 Mounting in a single gang box This module is compatible with Genesis Enhanced Integrity and Audible Detector base devices For specific and quantities see the compatibility list referenced on the panel in accordance with applicable requirements in the latest of the NFPA codes and standards and Canadian Code Part 1 Section 32 and in accordance with the authorities having jurisdiction Genesis Remote Mount Signal Master Module is from the factory as an assembled unit it contains user serviceable parts and should not be Signal Master Module only synchronizes appliances are electrically connected to it and are electrically of it Only one module is required for each notification circuit strobe circuit of the module requires a dedicated NAC the horn circuit of the module can be cascaded other Genesis Signal Master modules on one NAC strobe circuit must be continuous in alarm mode When determining allowable wire resistance refer to the rating of the module the signaling appliance and control panel specifications Compatible electrical box Remote Signal Master Wall plate x 1 2 in screw x 1 2 in screw 2013 UTC Fire Security All rights reserved 4 3100299 REV 07 REB 30JAN13 2 Horn silence synchronization using two NACs 4 Synchronization using one NAC Strobe or horn strobe To next appliance EOL resistor or Class A circuit return To next G1M RM or end of line resistor shown in alarm condition circuit can be silenced without turning off strobes Strobe or horn strobe To next appliance EOL resistor or Class A circuit return shown in alarm condition circuit cannot be silenced without turning off strobes 3 Horn silence synchronization using one NAC From previous device or control panel Strobe or horn strobe shown in alarm condition circuit can be silenced without turning off strobes CR module and wire nut must be located in the same enclosure as the Genesis Signal Master To next appliance EOL resistor or Class A circuit return To next device or Class A circuit return 4 3100299 REV 07 REB 30JAN13 2 G1M RM terminal connections IN IN OUT OUT IN IN OUT OUT voltage rating size box between two environment humidity to 33 VDC 16 33 VFWR A max Actual value limited by NAC and power outputs within 10 mss indefinitely max to 18 AWG 0.75 to 2.50 mm in 64 mm deep single gang box in square box 1 1 2 in 38 mm with single gang trim ring x 2 in 95 x 51 mm H x W or to 120 0 to 49 to 93 noncondensing information A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the product serial number on the product identification label are year of manufacture 24 DC Regulated 24 FWR 1 Indoor 1971 UL 1638 UL 464 CAN ULC S525 S526 of rating American This module was tested to the regulated 24 VDC FWR operating limits of 16 V and 33 V Do not apply 80 and 110 of these for system operation information contact information see www edwardsutcfs com 3100299 REV 07 REB 30JAN13 4 4 3100299 REV 07 REB 30JAN13