Edwards Genesis Speaker-Strobe nstallation Sheet

File Preview
File Preview
Click below to download for free

File Data

Name edwards-genesis-speaker-strobe-nstallation-sheet-8145697203.pdf
Type PDF
Size 3.22 MB
Downloads

Text Preview

Speaker Strobe Installation Sheet Genesis Speaker Strobe is a fire alarm notification designed for indoor walls See Table 1 for a list of numbers 1 Models VRMS 15 to 110 white VRMS 15 to 110 white with FIRE VRMS 15 to 110 white VRMS 15 to 110 white with FIRE mount box white MG4F S2VM MG4F S7VM speaker strobe includes field configurable switches for the desired candela output and wattage tap These lock in place and remain visible after final installation strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Signaling for the Hearing Impaired and the latest Canadian CAN ULC S526 Synchronized operation requires a installed synchronization control module See 2 for a list of compatible synchronization modules this device in accordance with applicable requirements the latest editions of the NFPA codes and standards and Electrical Code Part 1 Section 32 and CAN ULC Standard for the Installation of Fire Alarm Systems and accordance with the local authorities having jurisdiction 2 Compatible synchronization module models output module signal master mount To reduce the risk of shock disconnect all power allow 10 minutes for stored energy to dissipate before Electrical supervision requires the wire run to be at each terminal Do not loop the signaling circuit field around the terminals install the speaker strobe Remove the cover by depressing the tabs on top of the by inserting a small screwdriver from the top and slightly temporal strobe private mode operation is desired cut JP1 See Figure 2 Connect the speaker and strobe terminals to the signal field wiring For the unit to function properly polarity See Figure 5 Slide the candela switch to the desired candela output 15 75 or 95 cd by aligning it with the indicator below the See Figure 1 Slide the wattage switch to the desired wattage tap 2 W W 1 2 W or 1 4 W by aligning it with the indicator the switch See Figure 1 Mount the unit onto a compatible electrical box See 4 Replace the cover by aligning it at the bottom and it in at the top Test the unit for proper operation 2013 UTC Fire Security All rights reserved 4 3100273 REV 07 REB 30JAN13 1 Field configurable switches 4 Mounting diagram Wattage switch Bottom Candela switch 2 Strobe settings Strobe signal output Cut to change from 1 flash per second mode to temporal private mode If the strobe is set to temporal private mode this is no longer UL 1971 or ULC S526 Listed or FM but is UL 1638 Listed 3 UL 1971 minimum light output of rating vs angle Percentage of candela horizontal spec Percentage of candela vertical spec 4 3100273 REV 07 REB 30JAN13 5 Wiring Diagram First speaker strobe speaker strobe EOL resistor voltage determined by control panel output voltage must match the voltage ratings of the 25 or 70 VRMS Signal polarity is shown in the alarm condition 3 Strobe operating current in RMS A cd cd cd cd Volts direct current regulated and filtered Volts full wave rectified currents shown above were measured by UL at 16 VDC and VFWR 4 Sound level output dBA W W W W 1480 Sound level output at 10 ft 3.05 m measured in a room using 400 to 4,000 Hz band limited pink noise Meets or exceeds 85 dBA in an anechoic chamber at 10 ft m characteristics Within 6 dB of on axis sound level when 90 off axis horizontal unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction no change the factory applied finish voltage voltage operating level output response output settings size electrical humidity environment Installation VRMS model S2 or 70 VRMS model VDC 24 VFWR V maximum Table 3 Table 4 to 4,000 Hz at 15 30 75 and 110 cd flash per second fps to 18 AWG 0.75 TO 2.50 mm American 4 in square electrical box in deep no extension ring Series surface mount box See Table 1 to 120 0 to 49 to 93 noncondensing dry information of rating listings A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the DATE MFG number on the product identification label are year of manufacture 24 DC and 24 FWR device was tested to the regulated DC FWR operating voltage limits of 16 V and V Do not apply 80 and 110 of these for system operation Indoor UL 1971 requirements Maximum allowed between any two devices is 20 to specifications for the synchronization module this strobe and the control panel determine allowed wire resistance 1638 UL 1480 and UL 1971 S526 ULC S541 EN 60065 2002 1 Nameplate marking is located on the inside surface of the device information contact information see www edwardsutcfs com 3100273 REV 07 REB 30JAN13 4 4 3100273 REV 07 REB 30JAN13

Related Files