Edwards i-107XBR LED Beacon Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | edwards-i-107xbr-led-beacon-installation-instructions-8107462935.pdf |
---|---|
Type | |
Size | 745.97 KB |
Downloads |
Text Preview
Series Hazardous LED Strobe Light Sheet 1 Pendant mount in mm in mm 107XBR Series Hazardous Location LED Strobe Lights are for general utility signaling use They are available in bracket or ceiling mount configurations and in 120 V 60 Hz 24 VDC models The 107XBR Series is factory shipped in the mode but upon activation of a third yellow wire to ground the switches from the steady mode to a flashing mode that about 65 FPM devices are UL and cUL Listed for use in Class I Division 2 A B C and D and Class II Division 2 Groups F and G and III hazardous or nonhazardous locations Pendant mount with clear globes are also listed for Class II Division 1 Group F and G hazardous or nonhazardous locations See Table 1 for temperature codes devices are UL and cUL Listed as Type 3R and 4 enclosures and marine rated this strobe in accordance with the applicable requirements in the edition of the NFPA 70 National Electrical Code or CSA C22.1 Electrical Code using supply wire rated as shown in 1 Explosion hazard To reduce the risk of ignition of hazardous and shock keep the assembly tightly closed when are energized Explosion hazard Substitution of any component may impair for Class I Division 2 mounting options are available for the 107XBR Series Pendant mount Bracket mount Ceiling mount the appropriate method from the three options given below dimensions for each option are shown in the following figures 2 Bracket mount in mm in mm in mm in mm 3 Ceiling mount in mm in mm in mm in mm install pendant mount models an explosion proof hanger box not supplied Pull the wire leads through the 3 4 in NPT threaded conduit not Secure the 3 4 in threaded conduit to the mounting hood Ground the strobe in accordance with NFPA 70 or CSA C22.1 and requirements Wire in accordance with the instructions in on page 2 Secure the 3 4 in threaded conduit to the outlet box Where applicable install the optional guard assembly over the outer globe and secure it using the three screws supplied Apply power to the strobe and ensure proper function 3101649 EN REV 02 ISS 21NOV14 3 install bracket mount models Remove the outlet box from the end of the mounting bracket the outlet box using appropriate hardware not supplied for mounting surface Pull the field wiring through the outlet box Ground the strobe in accordance with NFPA 70 or CSA C22.1 and requirements Wire in accordance with the instructions in below Mount the wall bracket onto the outlet box Where applicable install the optional guard assembly over the outer globe and secure it using the three screws supplied Apply power to the strobe and ensure proper function install ceiling mount models Unscrew and remove the clear outer globe Remove the two holding the circuit assembly to the bottom of the fixture To the ceiling junction box from the fixture housing remove remaining two screws at the bottom of the fixture Mount the ceiling junction box using appropriate hardware Pull the wiring through the ceiling junction box Wire in accordance with the instructions in below Secure the fixture housing on the junction box by replacing the two removed above Reinstall the circuit assembly to the of the fixture using the two screws removed earlier Screw the clear outer globe back on to the fixture housing Where applicable install the optional guard assembly over the outer globe and secure using three screws supplied Apply power to the strobe and ensure proper function wire 24 VDC models Connect the red wire lead to the positive terminal of the power See Figure 4 Connect the black wire to the negative terminal or ground of the source desired set the flash pattern to 65 FPM by connecting the yellow to the positive terminal See Figure 5 wire 120 VAC models Connect the black wire to the AC hot terminal See Figure 4 Connect the white wire to the AC neutral terminal desired set the flash pattern to 65 FPM by connecting the yellow to the hot terminal See Figure 5 4 Steady mode wiring leads to source connected not supplied nuts not supplied units red positive units black hot units black negative units white neutral 5 Flashing mode wiring leads to source optional pattern units to positive units to hot nuts not supplied units red positive units black hot units black negative units white neutral strobe exterior surfaces and the outer globe should be cleaned with a soft clean cloth using water and a mild detergent to optimum light visibility Disconnect the power before cleaning is not necessary to disassemble the strobe to accomplish periodic Shock hazard To prevent electrical shock disconnect the power removing the outer globe Shock hazard To avoid risk of injury install the outer globe before the strobe 3 3101649 EN REV 02 ISS 21NOV14 1 Operating temperatures Supply I Div 2 A B C D II Div 1 Groups E G II Div 2 Groups F III Div 1 and 2 T6 T6 T6 Class II and Class III apply only to the pendant mount versions clear globes T4 T4 T4 VDC A 2 Electrical specifications VAC A temperature Table 1 size rate Letter denotes the color of the inner lens A Amber B Blue Green R Red or W White Only when the flashing mode is activated by connecting the third wire See on page 2 in NPT FPM information American and cUL ratings 12.12.01 C22.2 No 25 C22.2 No 30 C22.2 No 213 50 1203 1638 I Division 2 Groups A B C and D II Division 1 Groups E F G II Division 2 Groups F G III Divisions 1 and 2 3R 4 Marine Class II and Class III only apply to the pendant mount versions with globes Marine rating applies to the UL Listing only information contact information see www edwardssignaling com 2014 UTC Fire Security Americas Corporation Inc rights reserved 3101649 EN REV 02 ISS 21NOV14 3