Edwards Installation sheet, 116DEGEX-FJ

File Preview
File Preview
Click below to download for free

File Data

Name edwards-installation-sheet-116degex-fj-8013265974.pdf
Type PDF
Size 756.20 KB
Downloads

Text Preview

Class Fire Alarm Strobe Lights for Use in Locations Installation Sheet D Class I Division 2 Groups A B C and D Class II 1 Groups E F and G Class II Division 2 Groups and G and Class III Division 1 and 2 hazardous locations Operating Temperature Codes per Table 3 on page 5 to on page 5 for more information strobe is UL and cUL Listed as a Type 3R and 4X this unit in accordance with the applicable in the latest edition of the National Fire Alarm NFPA 72 National Electrical Code NFPA 70 and Electrical Code and CAN ULC S524 01 Standard the Installation of Fire Alarm Systems Wiring shall be in with the applicable requirements in the National Code NFPA 70 and CSA C22.1 Canadian Code Part I Safety Standard for Electrical Section 32 Do not change factory applied finishes Mount using one of the following applicable methods To reduce the risks of ignition of hazardous and shock do not apply power to the unit until has been completed and unit is tightly assembled secured Pendant Mount Models Figure 1 on page 2 the pendant mount module Cat No to the 116 main housing Tighten Install an explosion proof hanger box supplied Secure 3 4 NPT threaded conduit supplied to the box Install the unit on the Ensure the conduit engages at least five threads and then tighten the setscrew to secure pendant mount module to the conduit Connect field earth ground wire to the ground screw or ground via conduit system Wire in with Figure 5 on page 3 See Table 3 page 5 for required supply wire temperature Ceiling Mount Models Figure 2 on page 2 the ceiling mount module Cat No 116EX using hardware not supplied that is suitable for mounting surface Connect field earth ground to the ground screw or earth ground via system Wire the unit in accordance with 116 Class Fire Alarm Strobe Lights available in either a housing 116DEGEX FJ or a red housing 116DEGEX are in rush current limited strobe lights When wall or ceiling mounted and with dome guard they meet or exceed the requirements of UL 1971 Appliance for the Hearing Impaired strobe is intended for indoor use in UL 1971 signal for the hearing impaired listed compatible fire systems The strobe flashes a 360 degree beam of approximately 65 times per minute with a UL 1971 cd ceiling and 60 cd wall light output per Figure 7 and 8 With the guard installed the strobe flashes a with an output of 86 cd ceiling and 51 cd wall The is also UL 1638 visual signal appliance private listed with dome guard installed for both indoor and use and other applications requiring electrical of the signaling circuit field wiring In addition strobe is rated for outdoor use in Canada The 116 strobes are cUL listed to Canandian Standard ULC Visual Signal Device for Fire Alarm Systems for indoor and outdoor applications The strobe an enhanced synchronization circuit to comply with latest requirements of UL 1971 and CAN ULC S526 07 operation requires a separately installed control module See Table 1 on page 5 for list of compatible synchronization modules assembled with an available mounting subassembly 116EX R C or 116EX R C with 116EX R B in accordance with these instructions the 116 Class strobe signal is UL Listed as a Signaling Appliance for hearing impaired for use in Class I Division 1 Groups C 2011 UTC Fire Security All rights reserved 6 3101131 REV 04.00 ISS 24JUN11 2 Detail of ceiling mounting 5 on page 3 See Table 3 on page 5 for supply wire temperature ratings Install housing to the ceiling mount module Tighten setscrew to secure the 116 main housing to the mount module Bracket Mount Models Figure 3 below Install ceiling mount module Cat No 116EX C using not supplied that is suitable for the surface Install the wall mount module No 116EX B to the 116 main housing the setscrew to secure wall mounting to the main housing Run the unit wiring the elbow to the wall box Connect field ground wire to ground screw or earth ground conduit system Wire the unit in accordance Figure 5 on page 3 See Table 3 on page 5 required supply wire temperature ratings Install main housing and 116EX B wall mount module the ceiling mount module Tighten the setscrew secure the 116EX B wall mount module to the mount module To reduce the risk of ignition of hazardous and shock keep assembly tightly closed when are energized Apply power to the unit and ensure proper function 1 Detail of pendant mounting 3 Detail of wall bracket mounting 6 3101131 REV 04.00 ISS 24JUN11 4 Disassembly of the 116 Class fire alarm strobe To reduce the risk of ignition of hazardous and shock keep assembly tightly closed when are energized To reduce the risk of ignition of hazardous and shock disconnect from the supply and and allow five 5 minutes for stored energy to before disassembling the unit 5 Wiring Strobe Wire nut 6 Mounting options polarity of circuit shown in supervisory state signal inactive Reverse circuit polarity to activate signal supervision requires wire run to be broken at each device for constant input voltage Do not connect to or pulsating voltage non fire alarm use i e without field wire supervision the installer can tie the two white leads together and tie the two black leads 3101131 REV 04.00 ISS24JUN11 6 7 Effective candela light output for wall bracket mount plane zero degree angle at side of globe 8 Effective candela light output for ceiling mount X Y zero degree angle at bottom of globe dome guard shown candela output readings taken optional doe guard installed to on page 5 for candela ratings dome guard shown candela output readings taken optional dome guard installed to on page 5 for candela ratings 6 3101131 REV 04.00 ISS 24JUN11 names signal master remote numbers 2 116 Class catalog numbers less mounting mount module NPT mount module NPT mount module requires of ceiling mount module number color RMS operating rating without rating with 33 VDC FWR A at 24 VDC Regulated A at 24 VDC FWR cd cd cd cd To prevent damage to the signal circuit and to assure continued proper functioning DO NOT the unit outside of the regulated 24 VDC FWR voltage of 16 33 VDC V FWR Max RMS operating current is defined as the current rating over entire voltage range designation 24 refers to the voltage range of 16 volts 1 Compatible synchronization modules names output module numbers 3 Ratings temp wire temp I Div 2 A B 260 260 260 I Div 1 2 C D 85 85 85 II III Div 1 E F G 120 135 160 II III Div 2 F G 120 135 160 3101131 REV 04.00 ISS24JUN11 6

Related Files